• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Outdoor Ring Main Unit (RMU SF6)

  • Outdoor Ring Main Unit (RMU SF6)
  • Outdoor Ring Main Unit (RMU SF6)
  • Outdoor Ring Main Unit (RMU SF6)

Key attributes

Brand Wone
Model NO. Outdoor Ring Main Unit (RMU SF6)
Rated voltage 12kV
Series HXGN15

Product descriptions from the supplier

Description

Product overview: 

  • HXGN15-12  Ring Main Unit (SF6 sulfur hexafluoride gas switchgear), box type AC metal closed switchgear.

  • Rated AC frequency 50Hz/ 60Hz, maximum working voltage to 12kV, maximum working current to 4000A.

  • High reliability of operation verification in more than 50 countries and regions around the world,Kuwait, UAE, Saudi Arabia, Iraq, Qatar, Tanzania, Zimbabwe, Ghana, South Africa, Kenya, Zambia, Libya, Myanmar, Philippines, Bangladesh, Nepal,Uzbekistan, Kazakhstan, Kyrgyzstan, Mongolia, Indonesia, Pakistan,Vietnam etc.

  • Mainly used in factories, workshops, residential areas, high-rise buildings and other places of power distribution system, ring network power supply, also suitable for box substation.

  • Meet many international standards: IEC62271-200:2003, GB3906, etc.

Product advantages:
 Leading technology:

  •  Standard anti-corrosion and salt spray environmental plan to meet the stringent environmental requirements of the site.

  •  The components can be equipped with ABB's original HAD/US type ISF6 circuit breaker or VD4-S type vacuum circuit breaker.

  •  SFL-12/24 switchgear with components assembled in China can also be used according to the needs of users.

  •  With perfect and reliable mechanical linkage, interlocking device, fully achieve the "five prevention" function (IP3X).

Cabinet put oneself in another's position:

  •  The whole is made of 2mm hot dip galvanized plate.

  •  Laser numerical control equipment cutting, drilling, bending, to ensure the processing accuracy.

  • The exterior is coated with electrostatic epoxy powder, which will not take off paint for 50 years.

Functional units:

  •  Manual and electric operation, remote control function.

  •  Load switch, combination electrical appliances, its installation mode is flexible, can be installed on the left and right side, front, flip.

  •  Two pressure relief holes, cable room and bus room (load switch) at the back of cabinet.

Busbar system:

  •  High quality three-phase tin bus copper bar, high mechanical strength, good heat dissipation.

 Processing and assembly:

  •  Dust-free workshop to ensure insulation.

  •  Assembly workers have been trained for at least 6 months.

  • Use power tools to ensure proper torque for bolting reinforcement.

  •  The copper bus is CNC cutting, punching and bending to ensure the accuracy.

  • Leybold Helium Mass Spectrometry Leak Detector, Germany -- ensure that the leakage rate of SF6 gas tank is below the national standard.

  •  Computer-controlled equipressure pumping and inflating integrated equipment for vacuum chamber -- to ensure no deformation of gas box and 99.9% purity of SF6 gas.

Product parameters:
Conditions of use:

  •  Altitude shall not exceed 2000m.

  •  Ambient air temperature not higher than +40 ° C, not lower than -5 ° C (average temperature within 24 hours not higher than +35 ° C).

  •  The humidity of the surrounding air should not exceed 50%. Low temperature allows a large relative temperature (e.g. +20 ° C is 90%). Consideration should be given to the effect of condensation caused by temperature changes.

  •  Inclination with vertical plane is not more than 5°, and the whole group of cabinets is relatively flat, in line with (GBJ232-2) standard.

  •  Requested in no violent vibration and impact, electrical components will not be corroded, no conductive dust place.

Ordering instructions:
The customer shall provide the following information:

  • Main loop scheme diagram, secondary loop system diagram and auxiliary circuit control mode.

  • Equipment layout and distribution room layout.

  • Brand and model of main electrical components of the equipment.

  • Incoming and outgoing lines.

  • Other special requirements can be negotiated with WONE Electric.

What are the structural characteristics of the RMU SF6?

Fully Sealed and Fully Insulated:

  • SF6 gas has excellent insulating properties. The ring main unit (RMU) uses SF6 gas for common box insulation, with all switching components sealed within the main enclosure. This design effectively prevents external environmental factors such as condensation, contamination, and flooding from affecting the internal electrical components, ensuring safe and reliable operation. The protection level typically reaches IP67.

Compact and Space-Efficient:

  • The design is compact, requiring a small footprint, allowing it to be installed in limited spaces. It is suitable for various outdoor locations, such as city streets, residential areas, and industrial parks, effectively saving space resources.

Corrosion-Resistant Design:

  • The enclosure is typically designed with special anti-corrosion features and painted with a protective coating, providing good resistance to corrosion. This allows the equipment to withstand harsh environmental conditions such as acid rain and salt fog, extending its service life.



Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.