Attributa principalia

Marca Wone
Numerus Modeli Unitas Distributiva Externa (RMU SF6)
Votum nominatum 12kV
Series HXGN15

Descriptiones productorum a fornitori

Descriptio

Product overview:

  • HXGN15-12 Ring Main Unit (SF6 sulfur hexafluoride gas switchgear), box type AC metal closed switchgear.

  • Rated AC frequency 50Hz/ 60Hz, maximum working voltage to 12kV, maximum working current to 4000A.

  • High reliability of operation verified in more than 50 countries and regions around the world, including Kuwait, UAE, Saudi Arabia, Iraq, Qatar, Tanzania, Zimbabwe, Ghana, South Africa, Kenya, Zambia, Libya, Myanmar, Philippines, Bangladesh, Nepal, Uzbekistan, Kazakhstan, Kyrgyzstan, Mongolia, Indonesia, Pakistan, Vietnam, etc.

  • Mainly used in factories, workshops, residential areas, high-rise buildings, and other places of power distribution systems, ring network power supply, also suitable for box substations.

  • Meets many international standards: IEC62271-200:2003, GB3906, etc.

Product advantages:
Leading technology:

  • Standard anti-corrosion and salt spray environmental plan to meet the stringent environmental requirements of the site.

  • Components can be equipped with ABB's original HAD/US type ISF6 circuit breaker or VD4-S type vacuum circuit breaker.

  • SFL-12/24 switchgear with components assembled in China can also be used according to the needs of users.

  • With perfect and reliable mechanical linkage, interlocking device, fully achieving the "five prevention" function (IP3X).

Cabinet design:

  • The whole is made of 2mm hot dip galvanized plate.

  • Laser numerical control equipment cutting, drilling, bending, to ensure processing accuracy.

  • The exterior is coated with electrostatic epoxy powder, which will not peel off for 50 years.

Functional units:

  • Manual and electric operation, remote control function.

  • Load switch, combination electrical appliances, its installation mode is flexible, can be installed on the left and right side, front, flip.

  • Two pressure relief holes, cable room and bus room (load switch) at the back of cabinet.

Busbar system:

  • High quality three-phase tin-coated copper busbars, high mechanical strength, good heat dissipation.

Processing and assembly:

  • Dust-free workshop to ensure insulation.

  • Assembly workers have been trained for at least 6 months.

  • Use power tools to ensure proper torque for bolting reinforcement.

  • The copper bus is CNC cut, punched, and bent to ensure accuracy.

  • Leybold Helium Mass Spectrometry Leak Detector, Germany -- ensures that the leakage rate of SF6 gas tank is below the national standard.

  • Computer-controlled equipressure pumping and inflating integrated equipment for vacuum chamber -- to ensure no deformation of gas box and 99.9% purity of SF6 gas.

Product parameters:
Conditions of use:

  • Altitude shall not exceed 2000m.

  • Ambient air temperature not higher than +40 °C, not lower than -5 °C (average temperature within 24 hours not higher than +35 °C).

  • The humidity of the surrounding air should not exceed 50%. Low temperature allows a large relative temperature (e.g., +20 °C is 90%). Consideration should be given to the effect of condensation caused by temperature changes.

  • Inclination with vertical plane is not more than 5°, and the whole group of cabinets is relatively flat, in line with (GBJ232-2) standard.

  • Requested in no violent vibration and impact, electrical components will not be corroded, no conductive dust place.

Ordering instructions:
The customer shall provide the following information:

  • Main loop scheme diagram, secondary loop system diagram, and auxiliary circuit control mode.

  • Equipment layout and distribution room layout.

  • Brand and model of main electrical components of the equipment.

  • Incoming and outgoing lines.

  • Other special requirements can be negotiated with WONE Electric.

What are the structural characteristics of the RMU SF6?

Fully Sealed and Fully Insulated:

  • SF6 gas has excellent insulating properties. The ring main unit (RMU) uses SF6 gas for common box insulation, with all switching components sealed within the main enclosure. This design effectively prevents external environmental factors such as condensation, contamination, and flooding from affecting the internal electrical components, ensuring safe and reliable operation. The protection level typically reaches IP67.

Compact and Space-Efficient:

  • The design is compact, requiring a small footprint, allowing it to be installed in limited spaces. It is suitable for various outdoor locations, such as city streets, residential areas, and industrial parks, effectively saving space resources.

Corrosion-Resistant Design:

  • The enclosure is typically designed with special anti-corrosion features and painted with a protective coating, providing good resistance to corrosion. This allows the equipment to withstand harsh environmental conditions such as acid rain and salt fog, extending its service life.



Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 65666m²m² Numerus omnium laborantium: 300+ Summa Annua Exportatio (USD): 50000000
Locus Operis: 65666m²m²
Numerus omnium laborantium: 300+
Summa Annua Exportatio (USD): 50000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: cable et filum/Energia nova/Instrumenta inspectionis/apparatus electrum altum voltus/Aedificii electritas Apparatus electricus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/aestus apparatus/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
  • Quid est Differentia Inter Transformatores Rectificatores et Transformatores Potentiae?
    Quid est transformator rectificans?"Conversio potentiae" est terminus generalis qui conversionem, inversionem et conversionem frequentiae comprehendit, inter quas conversio praecipue usitatissima est. Apparatus rectificans convertit potentiam AC input in DC output per rectificationem et filtrationem. Transformator rectificans servit ut transformator alimentationis pro talibus apparatibus rectificantibus. In applicationibus industrialibus, plerumque alimenta DC obtinentur per combinandum transfor
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum