The power distribution room inspection robot RW400 is a low-cost intelligent inspection robot designed for inspections in areas such as information computer rooms, power distribution rooms, and switchgear rooms. This robot adopts a ground mobile design with SLAM laser navigation and is equipped with a lifting structure, enabling precise positioning to detection points. It features functions such as autonomous navigation, automatic obstacle avoidance, automatic charging, automatic identification of instrument readings, status indicator recognition, thermal infrared temperature measurement, partial discharge detection, and environmental monitoring. It can replace manual inspections and realize fully automatic intelligent inspections in areas like information computer rooms and power distribution rooms.

The power distribution room inspection robot can be applied in indoor venues such as power distribution rooms / equipment rooms / information computer rooms / communication rooms / IDC data centers / main control rooms / switchgear rooms / high-voltage switchgear rooms.

Product function

  • Scheduled and fixed-point inspection

  • Infrared temperature measurement

  • Automatic navigation

  • Fault alarm

  • Visible light video analysis

  • Temperature and humidity monitoring

  • Data analysis

  • Automatic detection

  • Voice intercom

  • 5G communication

  • Equipped with a liftable platform

  • Partial discharge detection

  • AI intelligent recognition

Mian feature

  • Object-oriented: Machine room
    RW400C is an intelligent inspection robot designed for inspections in areas such as machine rooms, power distribution rooms, and switch rooms.

  • Image recognition
    Automatically recognize meter readings, and identify the status of meters and switches.

  • Thermal infrared imaging
    Infrared intelligent extraction technology to identify the temperature of connectors, incoming and outgoing lines.

  • Noise detection
    Noise spectrum analysis to identify station equipment and environmental noise.

  • Gas detection
    Equipped with a gas sensor to collect the amount of ambient gas and monitor the environment.

  • Partial Discharge Detection
    Three-level robotic arm lifting + telescopic robotic arm, integrated detection function of transient low voltage and ultrasonic wave.

Technology Parameters

RW-400C

Basic Performance Parameters

  • Size: 420x427x1766mm (LxWxH)

  • Weight: 68Kg

  • Enclosure Protection Rating: IP34

  • Navigation Mode: LiDAR + IMU

  • Visible Light Camera: 1080P

  • Lifting Height: 0.45m - 1.6m

  • Endurance Time: 5h

  • Communication Mode: WIFI/5G

  • Shell Material: ABS Resin + Sheet Metal

  • Battery Capacity: 18Ah

  • Charging Voltage: 25.9V

  • Repeat Navigation Positioning Error: ≤±30mm

Display Screen (Optional)

  • Resolution: 1024x600P

  • Panel Size: 7-inch Touch Screen

Thermal Imaging Camera

  • Temperature Range: -20℃~350℃

  • Infrared Resolution: 160x120P (Optional)

Working Environment

  • Ambient Temperature: -20℃~60℃

  • Ambient Humidity: Can operate normally under 99% humidity conditions

Applicable Environment

  • Indoor inspection of power distribution rooms, IDC computer rooms, equipment rooms, information machine rooms, communication machine rooms, main control rooms, switch rooms, high-voltage switchgear rooms, etc.

Two-way Voice Intercom (Optional)

RW-400D(Dual-light PTZ Camera/Single-light PTZ)

  • Size: 420x427x850mm/420x427x950mm

  • Weight: 48Kg/55kg

  • Enclosure Protection Rating: IP34

  • Navigation Mode: LiDAR + IMU

  • Visible Light Camera: 1080P

Thermal Imaging Camera

  • Temperature Range: -20℃~350℃

  • Infrared Resolution: 160x120 (Optional)

Working Environment

  • Ambient Temperature: -20℃~60℃

  • Ambient Humidity: Can operate normally under 99% humidity conditions

 

 

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.