GRF8-01 Frequency Relay

  • GRF8-01 Frequency Relay

Key attributes

Brand Switchgear parts
Model NO. GRF8-01 Frequency Relay
Rated frequency 40Hz-70Hz
Series GRF8

Product descriptions from the supplier

Description

The GRF8-01 frequency relay is a high-precision and highly reliable power monitoring device designed specifically for power frequency monitoring and protection. It is also known as a power frequency monitoring relay, power frequency monitoring relay, frequency monitoring relay, or dual-mode frequency adjustable relay. This product integrates intelligent functions and user-friendly operation, and can be widely used in generator sets, power systems, and industrial equipment. The stability of power frequency and the safety of equipment operation provide efficient guarantees for critical power scenarios.

Application of GRF8-01 frequency relay product:
As the frequency guardian of the power system, GRF8-01 performs in the following areas:
1. Generator set monitoring: Real time detection of diesel/gas generator output frequency. When the fluctuation exceeds the set threshold of ± 2%, the protection mechanism is triggered within 0.1 seconds to prevent equipment damage
2. Microgrid system: achieving multi power frequency synchronization and precise phase matching during grid switching in integrated wind solar energy storage systems
3. Industrial production line: provides frequency anomaly warning for precision machining equipment to avoid batch defects caused by power grid fluctuations
4. Ship power system: certified according to EN60945, suitable for humid and salt spray environments at sea, ensuring the stability of power supply for ship auxiliary equipment

Product features of GRF8-01 frequency relay:
1. Dual power monitoring mechanism
GRF8-01 not only monitors the external power frequency in real-time, but also has the continuous monitoring function of its own working power supply. This design effectively avoids monitoring failures caused by abnormal internal power supply of the equipment, improves system reliability from the source, and ensures no blind spots in monitoring.
2. Intelligent frequency switching adaptation
Built in 50Hz/60Hz dual-mode adjustable configuration, can be quickly switched through panel dip switch, perfectly adapting to power grid standards in different regions around the world. Whether it is European industrial equipment or power generation units in the Asia Pacific region, they can be seamlessly compatible and expand equipment application scenarios.
3. Multi state visualization diagnosis
Innovatively adopting LED indicator light system: green, red, combined with strobe coding technology, supporting rapid identification of 21 types of faults. With the design of a transparent observation window, operation and maintenance personnel can intuitively grasp the equipment status from 10 meters away, greatly reducing the time for fault location.
4. Dual mode fault recovery system
Industry mechanical rotary recovery mode selector, providing two strategies: "fault locking" and "automatic reset". Maintain a safe state after a critical system failure in lock mode and wait for manual intervention; Automatic reset mode with adjustable delay restart, especially suitable for unmanned power plants. The knob adopts IP20 protection level and is suitable for high dust and humid environments.

Model GRF8-01 Frequency Relay
Function Monitoring frequency
Supply terminals A1-A2
Rated supply voltage AC120-277V
Supply voltage limits AC100-310V
Monitoring frequency range 40Hz-70Hz
Over threshold value -2…+10 Hz
Under threshold value -10…+2 Hz
Hysteresis fixed 0.3Hz
Measurement error ±0.05Hz
Time delay Adjustable 0.1s-10s,10%
Delay at power up 0.5s
Temperature coecient 0.05%/℃,at=20℃(0.05%℉,at=68℉)
Output indication green LED
Output 2×SPDT
Current rating 8A/AC1
Switching voltage 250VAC/24VDC
Min.breaking capacity DC 500mW
Fault indication red LED
Mechanical life 1×107
Electrical life(AC1) 1×105
Operating temperature -20℃ to +55℃(-4℉ to 131℉)
Storage temperature -35℃ to +75℃(-22℉ to 158℉)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage cathegory III.
Pollution degree 2
Max.cable size(mm²) solid wire max.1×2.5 or 2×1.5/with sleeve max.1×2.5(AWG 12)
Tightening torque 0.4Nm
Dimensions 90×18×64mm
Weight 59g
Standards EN/IEC60947-5-1
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.