33MVA138kV transformer for electrical transmission

  • 33MVA138kV transformer for electrical transmission

Key attributes

Brand ROCKWILL
Model NO. 33MVA138kV transformer for electrical transmission
Rated frequency 50/60Hz
Series S (F)

Product descriptions from the supplier

Description

Description of 110kV Transmission Transformer

A 110kV Transmission Transformer is a medium-to-high voltage power transformer designed for regional electricity transmission and distribution networks. It serves as a critical link between high-voltage transmission grids (e.g., 220kV/500kV) and local distribution systems, stepping down voltage from 110kV to lower levels (typically 10kV/35kV) for industrial, commercial, and residential use. Widely deployed in substations, industrial parks, and urban/rural areas, it ensures stable power supply, reduces transmission losses over medium distances, and supports reliable grid operation.

  • 3-ph, 33MVA138kV Transformer 

Features of 110kV Transmission Transformer

  • Optimal Voltage Level: Balances transmission efficiency and infrastructure cost, making it ideal for medium-distance power delivery (up to 100km) while minimizing voltage drop and energy loss.

  • High Efficiency & Low Loss: Adopts advanced materials (e.g., amorphous alloy cores, low-resistance copper windings) to reduce no-load and load losses, meeting or exceeding international standards (e.g., IE3 efficiency class).

  • Robust Construction: Designed to withstand environmental stresses (e.g., temperature variations, humidity, pollution) with sealed tanks, corrosion-resistant coatings, and moisture-proof insulation systems.

  • Flexible Configuration: Available in various types (e.g., oil-immersed, dry-type), with options for on-load or off-circuit tap changers to regulate output voltage under fluctuating loads.

  • Safety & Reliability: Equipped with protective devices (e.g., overcurrent/overvoltage relays, temperature sensors) and fail-safe mechanisms to prevent malfunctions and ensure continuous operation.

  • Compact Design: Space-efficient footprint for easy installation in urban substations or confined spaces, often featuring noise-reducing enclosures to meet environmental regulations.

  • Smart Grid Compatibility: Integrated with IoT sensors for real-time monitoring of temperature, oil quality, and partial discharges, enabling predictive maintenance and remote diagnostics.

3-ph, 160MVA138kV Transformer

80MVA132kV Transformer

 

FAQ
Q: What are the main classification dimensions of power transformers in international and domestic standards, and what are the specific types?
A:
The core classification dimensions of power transformers include insulation and cooling methods, voltage functions, and core structures. The specific types under each dimension are as follows:
  • By insulation and cooling method: Divided into liquid-insulated (oil-immersed) and dry-type. Oil-immersed transformers are the mainstream type for power transmission, suitable for voltages up to 345kV and above, with standardized cooling methods such as ONAN (Oil Natural Air Natural), ONAF (Oil Natural Air Forced), and OFAF (Oil Forced Air Forced). Dry-type transformers are mainly used for indoor or specific industrial applications, typically for lower voltages (up to 35kV), although some special types are available for higher voltages.
  • By voltage function: Including step-up, step-down, and autotransformers. Step-up transformers are used in power plants to increase generator voltage to transmission voltage (e.g., 13.8kV to 345kV). Step-down transformers are used in substations to reduce transmission voltage for sub-transmission or distribution (e.g., 345kV to 132kV or 34.5kV). Autotransformers are used to connect systems with fixed voltage ratios, offering efficiency advantages in transmission grids (e.g., 400kV/220kV applications).
  • By core structure: Divided into core type and shell type. Core-type transformers have windings surrounding the core limbs (common in EHV applications). Shell-type transformers have the core surrounding the windings.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.