• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


1000kV/1000MVA transformer for power transmission

  • 1000kV/1000MVA transformer for power transmission

Key attributes

Brand ROCKWILL
Model NO. 1000kV/1000MVA transformer for power transmission
Rated frequency 50/60Hz
Series ODFPS

Product descriptions from the supplier

Description

Description of 1000kV Transmission Transformer

A 1000kV Transmission Transformer is a cutting-edge ultra-high voltage (UHV) power equipment designed for long-distance, large-capacity electricity transmission in UHV AC grids. Its core function is to step up or step down voltage at key grid nodes: when connected to power sources (e.g., large hydropower, thermal, or nuclear plants), it boosts electricity to 1000kV for efficient long-haul transmission, minimizing line losses; at receiving ends, it reduces 1000kV to lower levels (e.g., 500kV) for distribution to regional grids. As a cornerstone of UHV networks, it enables cross-regional power allocation, supporting the integration of remote clean energy (e.g., west-to-east power transmission in China) and enhancing grid stability.

  • 1-ph, 1000kV,1000MVA

Features of 1000kV Transmission Transformer

  • Ultra-High Voltage & Large Capacity: Operates at a rated voltage of 1000kV, with single-unit capacities typically ranging from 1000MVA to 2400MVA. This allows it to transmit over 10GW of power per circuit, far exceeding the capacity of 500kV transformers, making it ideal for nationwide energy transmission.

  • Low Transmission Loss: Adopts advanced technologies such as ultra-thin high-permeability silicon steel cores, optimized winding designs, and low-resistance conductors. These reduce no-load and load losses by 20–30% compared to 500kV transformers, ensuring over 99% efficiency even over thousands of kilometers.

  • Robust Insulation & Safety: Uses high-quality insulation materials (e.g., nanocomposite paper, refined transformer oil) and multi-level insulation structures to withstand extreme electric fields (up to 400kV/m). Equipped with sophisticated monitoring systems (e.g., partial discharge sensors, oil chromatography analyzers) to detect faults early and prevent insulation breakdown.

  • Environmental Adaptability: Designed to operate in diverse conditions, including high-altitude regions (≥3000m), seismic zones (up to 9 degrees), and extreme temperatures (-40°C to 50°C). Features enhanced cooling systems (e.g., forced oil circulation with air/water cooling) to maintain stable performance in harsh climates.

  • Modular & Transport-Friendly Design: For remote or mountainous areas, some models use split-type structures (disassembled into core, windings, and tank) for easier transportation. On-site assembly ensures they can be deployed in locations with challenging logistics, such as valleys or plateaus.

  • Grid Stability Support: Integrates with smart grid systems via digital interfaces, enabling real-time voltage regulation, reactive power compensation, and synchronization with grid frequency. This helps mitigate voltage fluctuations and improves the resilience of UHV networks against load changes or faults.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.