100kVA 135kVA 150kVA Three-phase dry-type power transformer

  • 100kVA 135kVA 150kVA Three-phase dry-type power transformer

Key attributes

Brand ROCKWILL
Model NO. 100kVA 135kVA 150kVA Three-phase dry-type power transformer
Rated frequency 50/60Hz
Rated capacity 150KVA
Series S(D)G

Product descriptions from the supplier

Description

Product Description

As a pioneer in China's power transformer industry, we have specialized in the R&D and manufacturing of power transformer equipment for decades, and established industry standards with core technologies.

Our 100kVA 135kVA 150kVA Three-Phase Dry-Type Power Transformer is engineered for superior performance, safety, and reliability in a wide range of commercial and industrial applications. Unlike liquid-filled units, this transformer utilizes advanced vacuum pressure impregnation (VPI) and encapsulation technology with high-class insulating materials, making it inherently flame-retardant, self-extinguishing, and free from oil leaks or environmental contaminants.

Designed for exceptional operational efficiency with low no-load and load losses, it significantly reduces energy consumption and total cost of ownership. Its robust construction ensures stable voltage transformation and distribution in demanding environments, from powering manufacturing equipment and HVAC systems to serving as a critical component in data centers and building infrastructure. With easy installation, minimal maintenance requirements, and a compact footprint, this 150kVA dry-type transformer represents a smart, safe, and eco-friendly power solution built for long-term dependability.

Product features

Special Transformer SG and DG Series include three-phase (single-phase) isolation transformers and three-phase (single-phase) autotransformers. They are primarily used in various high and low voltage complete electrical sets, import-export equipment, precision machine tools, UPS, electroplating, lighting, heating, communications, chemical industry equipment, and other applications for control power and power supply purposes. These transformers feature effective harmonic resistance, strong anti-interference capability, and high safety. Design and production strictly comply with IEC international standards and relevant GB national standards.

SG DG Dry-type Transformer Technical Parameters

The voltage classes of some of these Power Transformer include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV  69kV.72.5kV 88kV 110kV 115kV 123kV 125kV 126kV 132kV 138kV 145kV 150kV 154kV 161kV 170kV  220kV 225kV 230kV 245kV 275kV 330kV 345kV 363kV 380kV 400kV 500kV Power transformers of voltage ,and aboveand customization is available.

Product Name

Model Specification

Parameter Ratio (kV)

Connection Group

Overall Dimensions (Length * Width * Height, mm)

Foot Mounting Dimensions (mm)

Total Weight (kg)

Single-phase Small Dry-type Transformer

DG-1kVA

0.38/0.22

 

Dyn11/Yyn0

 

162 * 185 * 190

100 * 115

13

DG-1.5kVA

191 * 170 * 200

130 * 135

17

DG-2kVA

230 * 180 * 250

190 * 120

23

DG-2.5kVA

230 * 185 * 250

190 * 125

25

DG-3kVA

230 * 190 * 250

190 * 130

30

DG-4kVA

230 * 200 * 250

190 * 150

38

DG-5kVA

230 * 210 * 250

190 * 160

46

DG-6kVA

230 * 220 * 250

190 * 175

55

DG-8kVA

230 * 230 * 250

190 * 185

62

DG-10kVA

270 * 270 * 250

170 * 150

70

Three-phase Small Dry-type Transformer

SG-1kVA

0.315/0.38

0.315/0.4

0.38/0.38

0.38/0.22

0.38/0.22

0.62/0.4

0.69/0.4

280 * 140 * 280

200 * 90

19

SG-1.5kVA

280 * 155 * 280

200 * 105

24

SG-2kVA

280 * 160 * 280

200 * 110

26

SG-2.5kVA

280 * 170 * 280

200 * 120

29

SG-3kVA

310 * 170 * 300

200 * 125

38

SG-4kVA

310 * 175 * 300

200 * 130

42

SG-5kVA

360 * 170 * 350

200 * 125

50

SG-8kVA

410 * 175 * 400

200 * 125

72

SG-10kVA

410 * 180 * 400

200 * 135

78

SG-12kVA

410 * 195 * 400

200 * 145

92

SG-15kVA

410 * 195 * 400

200 * 145

92

SG-20kVA

480 * 225 * 450

200 * 165

130

SG-30kVA

520 * 350 * 550

280 * 300

210

SG-35kVA

540 * 350 * 610

300 * 300

230

SG-40kVA

580 * 350 * 610

300 * 300

270

SG-50kVA

580 * 350 * 610

300 * 300

310

SG-60kVA

710 * 450 * 720

400 * 400

360

SG-70kVA

710 * 450 * 720

400 * 400

390

SG-80kVA

850 * 500 * 720

450 * 450

400

SG-90kVA

850 * 500 * 780

450 * 450

420

SG-100kVA

850 * 500 * 780

450 * 450

430

SG-110kVA

850 * 500 * 780

450 * 450

450

SG-120kVA

850 * 500 * 820

450 * 450

480

SG-130kVA

850 * 500 * 780

450 * 450

500

SG-135kVA

870 * 600 * 820

500 * 550

520

SG-140kVA

870 * 600 * 820

500 * 550

540

SG-150kVA

870 * 600 * 820

500 * 550

550

Note: the above parameters are for reference only and can be customized according to customer requirements.

Conditions of use

  • The upper limit of ambient temperature is +40℃, and the lower limit is -5℃ (indoor).

  • The altitude does not exceed 1000m.

  • The daily average relative humidity ≤ 95%, and the monthly average relative humidity ≤90%.

  • For special sites, please state in advance, and our company will make corresponding design adjustments.

FAQ
Q: What is the capacity range of power transformers up to 345kV, and what are the standardized capacity ratings?
A:
Transformer capacity is strongly related to voltage level, and the capacity range and standard values comply with international general specifications. Details are as follows:
  • Capacity range by voltage level: ① High Voltage (HV, 66kV - 220kV): 5MVA – 250MVA; ② Extra-High Voltage (EHV, 220kV - 400kV): 250MVA – 600MVA+. Higher capacities are usually achieved through forced cooling methods (e.g., ONAF, OFAF).
  • Standardized capacity ratings: Internationally accepted standard capacities include 30MVA, 45MVA, 60MVA, 90MVA, 100MVA, 120MVA, 150MVA, 200MVA, 250MVA, 315MVA, 400MVA, and 500MVA. These ratings are widely adopted in design and production.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.