• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


24kV 30kV 33kV 33.5kV Maintenance-Free zero gas switchgear/distribution board source manufacturer

  • 24kV 30kV 33kV 33.5kV Maintenance-Free zero gas switchgear/distribution board source manufacturer

Key attributes

Brand ROCKWILL
Model NO. 24kV 30kV 33kV 33.5kV Maintenance-Free zero gas switchgear/distribution board source manufacturer
Rated voltage 24kV
Rated normal current 1250A
Rated frequency 50/60Hz
Series PureInsul

Product descriptions from the supplier

Description

Description

The 24kV 30kV  33kV 33.5kV Maintenance-Free Gas-Insulated Switchgear is a cutting-edge medium-voltage power distribution device engineered for efficiency, reliability, and low operational overhead. Designed to meet the demands of modern urban grids, industrial facilities, and renewable energy projects, it combines advanced gas insulation technology with a maintenance-free architecture to eliminate routine upkeep—all while ensuring stable power transmission.

Featuring hermetically sealed stainless-steel enclosures filled with low-GWP (Global Warming Potential) insulating gas, the switchgear avoids gas leakage and degradation, eliminating the need for regular refills or component inspections. As a key unit in 24kV distribution networks, it delivers consistent performance in diverse environments, from high-humidity industrial zones to compact urban substations, making it a sustainable choice for long-term grid stability.

Feature

  • True Maintenance-Free Operation:Hermetic gas chambers (leak rate ≤0.05%/year) and wear-resistant mechanical components eliminate routine tasks like gas replenishment, part replacement, or cleaning. Reduces lifecycle operational costs by up to 70% compared to traditional switchgear.

  • 24kV-Level Reliability:Equipped with vacuum interrupters for efficient arc extinction and robust insulation, it withstands short circuits (up to 25kA/3s) and voltage fluctuations, ensuring a power supply reliability rate of ≥ 99.99%.

  • Eco-Friendly Gas Insulation:Uses low-GWP insulating gas (compliant with EU F-gas regulations) to minimize environmental impact. Fully sealed design prevents gas leakage, enhancing safety for personnel and surrounding ecosystems.

  • Compact & Flexible Installation:Modular design reduces footprint by 30% vs. air-insulated alternatives, fitting tight spaces like underground substations or industrial workshops. Supports quick on-site assembly for rapid deployment.

  • Smart Readiness:Compatible with intelligent monitoring systems to track real-time parameters (gas pressure, temperature, operational status) and trigger alerts for anomalies, enabling predictive grid management.

Product Parameters

The voltage classes of some of these eco-friendly switchgears include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. and customization is available.

Serial Number

Item

Unit

Parameter

1

Rated Voltage

kV

24kV 30kV  33kV 33.5kV

2

Rated Current

A

630/1250

3

Rated Frequency

Hz

50

4

1minPower Frequency Withstand Voltage

Phase-to-Phase and Ground

kV

65

Isolation Break

kV

79

5

Lightning Impulse Withstand Voltage

Phase-to-Phase and Ground

kV

125

Break

kV

145

6

Rated SF6 Gas Pressure

(Gauge Pressure at 20℃)

MPa

0.04

7

SF6Annual Leakage Rate

%

≤0.05

8

Protection Level

SF6Gas Chamber

IP67

Cabinet Body

IP4X

Environmental Conditions:

  • Altitude Range: ≤3000 m (High-altitude design extendable to 4000 m)

  • Operating Temperature: -25℃ to +50℃ (Short-term operation at ≤+60℃ for ≤4 hours within 24 hours is permissible)

  • Relative Humidity: Daily average ≤95%, monthly average ≤90% (Condensation-free environment)


Documentation Resource Library
Restricted
ESKOM Distribution materials specification for 3.3 to 33kV ring mian units
Other
English
Consulting
Consulting
FAQ
Q: What are the environmental protection advantages of environmentally friendly cabinets compared with ordinary power distribution cabinets?
A:
Compared with ordinary power distribution cabinets, eco-friendly cabinets use pollution-free insulating media that do not release harmful substances or cause greenhouse effects. They avoid the environmental risks of SF6 leakage and waste gas treatment. Moreover, their compact design reduces material consumption, and most components are recyclable, aligning with low-carbon and environmental protection development trends.
Q: Is the insulation performance of environmentally friendly cabinets as reliable as that of SF6 cabinets?
A:
Yes, the insulation performance of qualified environmentally friendly cabinets is equally reliable. By using optimized eco-friendly insulating media (e.g., compressed dry air, N2/CO2 mixture) and advanced sealed cavity design, their insulation strength can reach or approach that of SF6 cabinets. They also have excellent anti-pollution and anti-humidity performance, which is verified by strict type tests in accordance with IEC and national standards.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.