24kV 40.5kV 27.5kV SF6 Gas Insulated Metal-clad Switchgear

  • 24kV 40.5kV 27.5kV SF6 Gas Insulated Metal-clad Switchgear

Key attributes

Brand ROCKWILL
Model NO. 24kV 40.5kV 27.5kV SF6 Gas Insulated Metal-clad Switchgear
Rated voltage 40.5kV
Series RGS

Product descriptions from the supplier

Description

Description:

SF6 Gas Insulated Metal-clad switchgear, RGIS-G20 designed up to 40.5kV 3-phase 3 wire 50/60 Hz system.The switchgear shall be rated up to 40.5kV and has horizontally or Vertically installed vacuum circuit breakers.The switchgear includes vacuum circuit breakers,meters, relays, etc.

Feature:

  • Compactness

  • Automation

  • HighReliability and Safety

  • Easy Expansion

  • Simple Installation

  • Economy.

Environmental Qualification:

The switchgear equipments is evaluated by optimum analysis and test for easy maintenance and long lifetime. Hermetically sealed primary enclosure for protection against environmental conditions (dirt,moisture, vermins, insects and high altitudes).

Technical parameters:

 image.png

RGIS-G20 Switchgear:

企业微信截图_17210289451663.png

RGIS-G20 series gas insulated metal-clad switchgear are applied to single bus system merely, voltage class up to 40.5kV. Voltage transformer and surge arrester used for main bus could be well arranged in one panel, be easy to maintenance.

企业微信截图_17210292689170.png

RGIS-G80 Switchgear:

企业微信截图_17210298611843.png

RGIS-G80 series gas insulated metal-clad switchgear applicable to single or double bus system can carry out the combination of various schemes. The application of plug-in technology which makes voltage transformer and surge arrester arranged in incoming panel or surge arrester arranged in feeder panel.That could save the space sharply.

企业微信截图_17210304263817.png

企业微信截图_17210304993437.png

RGIS-G90 Switchgear:

企业微信截图_17210298611843.png

image.png

image.png

What are the technical parameters of SF6 gas-insulated metal armored switchgear?

Rated Voltage:

  • Common rated voltage levels include 12kV, 24kV, and 40.5kV, and can be selected based on the voltage level of the power system and application requirements.

Rated Current:

  • The range of rated current values is broad, typically from a few hundred amperes to several thousand amperes, such as 630A, 1250A, 1600A, 2000A, 3150A, etc. The specific value depends on the size of the connected load and the capacity requirements of the power system.

Rated Short-Circuit Breaking Capacity:

  • Typically ranges from 20kA to 50kA. This parameter reflects the switchgear's ability to interrupt short-circuit currents. The rated short-circuit breaking capacity must be greater than the maximum possible short-circuit current in the power system to ensure reliable interruption of fault currents during a fault, preventing the accident from escalating.

Gas Pressure:

  • The rated pressure for SF6 gas is generally between 0.03MPa and 0.16MPa. The actual operating pressure may be adjusted according to the specific requirements of the equipment and environmental factors such as temperature. During operation, it is necessary to monitor and control the gas pressure to ensure it remains within the specified range, thereby ensuring the insulation and arc-quenching performance of the equipment.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026
  • A Brief Discussion on the Selection of Grounding Transformers in Boost Stations
    A Brief Discussion on the Selection of Grounding Transformers in Boost StationsThe grounding transformer, commonly referred to as "grounding transformer," operates under the condition of being no-load during normal grid operation and overloaded during short-circuit faults. According to the difference in filling medium, common types can be divided into oil-immersed and dry-type; according to phase number, they can be classified into three-phase and single-phase grounding transformers. The groundi
    01/27/2026
  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.