• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


24kV 40.5kV 27.5kV SF6 Gas Insulated Metal-clad Switchgear

  • 24kV 40.5kV 27.5kV SF6 Gas Insulated Metal-clad Switchgear

Key attributes

Brand ROCKWILL
Model NO. 24kV 40.5kV 27.5kV SF6 Gas Insulated Metal-clad Switchgear
Rated voltage 24kV
Series RGS

Product descriptions from the supplier

Description

Description:

SF6 Gas Insulated Metal-clad switchgear, RGIS-G20 designed up to 40.5kV 3-phase 3 wire 50/60 Hz system.The switchgear shall be rated up to 40.5kV and has horizontally or Vertically installed vacuum circuit breakers.The switchgear includes vacuum circuit breakers,meters, relays, etc.

Feature:

  • Compactness

  • Automation

  • HighReliability and Safety

  • Easy Expansion

  • Simple Installation

  • Economy.

Environmental Qualification:

The switchgear equipments is evaluated by optimum analysis and test for easy maintenance and long lifetime. Hermetically sealed primary enclosure for protection against environmental conditions (dirt,moisture, vermins, insects and high altitudes).

Technical parameters:

 image.png

RGIS-G20 Switchgear:

企业微信截图_17210289451663.png

RGIS-G20 series gas insulated metal-clad switchgear are applied to single bus system merely, voltage class up to 40.5kV. Voltage transformer and surge arrester used for main bus could be well arranged in one panel, be easy to maintenance.

企业微信截图_17210292689170.png

RGIS-G80 Switchgear:

企业微信截图_17210298611843.png

RGIS-G80 series gas insulated metal-clad switchgear applicable to single or double bus system can carry out the combination of various schemes. The application of plug-in technology which makes voltage transformer and surge arrester arranged in incoming panel or surge arrester arranged in feeder panel.That could save the space sharply.

企业微信截图_17210304263817.png

企业微信截图_17210304993437.png

RGIS-G90 Switchgear:

企业微信截图_17210298611843.png

image.png

image.png

What are the technical parameters of SF6 gas-insulated metal armored switchgear?

Rated Voltage:

  • Common rated voltage levels include 12kV, 24kV, and 40.5kV, and can be selected based on the voltage level of the power system and application requirements.

Rated Current:

  • The range of rated current values is broad, typically from a few hundred amperes to several thousand amperes, such as 630A, 1250A, 1600A, 2000A, 3150A, etc. The specific value depends on the size of the connected load and the capacity requirements of the power system.

Rated Short-Circuit Breaking Capacity:

  • Typically ranges from 20kA to 50kA. This parameter reflects the switchgear's ability to interrupt short-circuit currents. The rated short-circuit breaking capacity must be greater than the maximum possible short-circuit current in the power system to ensure reliable interruption of fault currents during a fault, preventing the accident from escalating.

Gas Pressure:

  • The rated pressure for SF6 gas is generally between 0.03MPa and 0.16MPa. The actual operating pressure may be adjusted according to the specific requirements of the equipment and environmental factors such as temperature. During operation, it is necessary to monitor and control the gas pressure to ensure it remains within the specified range, thereby ensuring the insulation and arc-quenching performance of the equipment.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025

Related Solutions

  • Analysis of Common Problems in 10kV Gas-Insulated Ring Main Units (RMUs)
    Introduction:10kV gas-insulated RMUs are widely used due to their numerous advantages, such as being fully enclosed, possessing high insulation performance, requiring no maintenance, having a compact size, and offering flexible and convenient installation. At this stage, they have gradually become a critical node in urban distribution network ring-main power supply and play a significant role in the power distribution system. Problems within gas-insulated RMUs can severely impact the entire dist
    08/16/2025
  • Application of Intelligent Solid Insulated Ring Main Units (SIRMUs) in the Qinzhou Distribution Network
    1 IntroductionCoastal regions face environmental challenges including heavy rainfall, lightning, high temperatures, high humidity, and high salt spray corrosion. To ensure the safety of urban distribution grids in such environments, minimize power outages caused by equipment maintenance, and prevent accidents due to equipment end-of-life and other factors affecting grid security, we have researched the use of a new type of Solid Insulated Ring Main Unit (SIRMU). This SIRMU offers long lifespan,
    08/15/2025
  • SF₆ Ring Main Units (RMUs) and Urban Grid Renovation
    Overview​Older distribution networks are primarily radial in structure, with most incoming and outgoing lines being overhead lines. The switching equipment typically consists of air-insulated vacuum circuit breakers or minimal-oil circuit breakers. These networks suffer from frequent faults, high operating costs, and prolonged, widespread power outages in the event of a failure, significantly hindering economic development.With rapid economic growth and the implementation of urban grid renovatio
    08/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.