20kW/30kW/40kW BI-DIRECTIONAL DC Fast Charger V2G/V2L/V2H

  • 20kW/30kW/40kW BI-DIRECTIONAL DC Fast Charger V2G/V2L/V2H
  • 20kW/30kW/40kW BI-DIRECTIONAL DC Fast Charger V2G/V2L/V2H

Key attributes

Brand RW Energy
Model NO. 20kW/30kW/40kW BI-DIRECTIONAL DC Fast Charger V2G/V2L/V2H
Rated Output Rating 40KW
Output Voltage DC 200-1000V
Power Conversion Efficiency ≥95%
Connector Options CCS2
Cable Length 5m
Input Voltage 380V
Series WZ-V2G

Product descriptions from the supplier

Description

This BI-DIRECTIONAL DC Fast Charger supports three major modes: V2G (Vehicle-to-Grid), V2L (Vehicle-to-Load), and V2H (Vehicle-to-Home), redefining electrical energy interaction. With V2G technology, vehicles can charge during low-power consumption periods and feed power back to the grid during peak hours, aiding in peak shaving and valley filling while generating revenue. In V2L mode, the charger transforms into a high-power mobile power source, providing stable electricity for camping equipment, outdoor machinery, emergency rescue gear, and other loads. The V2H function enables electric vehicles to serve as home backup power, ensuring household appliances operate during power outages or optimizing home electricity costs. Supporting a maximum charging power of 350kW and discharging power of 100kW, it is equipped with an intelligent power regulation and bidirectional energy management system to ensure efficient, stable, and safe bidirectional power transmission, making it a core device for the future smart energy ecosystem.

Features

  •  Connectors - GBT/CCS1/CCS2/CHAdeMO/Tesla.

  • Support V2G/V2L/V2H.

  • Configurable output power settings.

  • RFID Reader.

  • Optional Credit Card Reader.

  •  Station-level monitoring platform.

  • FRU Onboard Diagnostics.

  •  Easy to Service.

Specifications

image.png

image.png

image.png

image.png

Bi-directional function:

  • V2G (Vehicle to Grid): Vehicle to grid. That is, electric vehicles can not only obtain electrical energy from the grid for charging, but also feed back the electrical energy in the vehicle battery to the grid under certain circumstances to realize reverse transmission of electrical energy. This helps to peak-shave and valley-fill the grid, improve the stability and efficiency of the grid. At the same time, vehicle owners may also obtain certain economic benefits.

  • V2L (Vehicle to Load): Vehicle to load. It can use electric vehicles as a mobile power source to supply power to other external load devices. For example, when camping outdoors, it can supply power to electric ovens, stereos and other devices, expanding the usage scenarios of electric vehicles.

  • V2H (Vehicle to Home): Vehicle to home. It enables electric vehicles to be connected to the home's power system and provide emergency power for the home in case of power outages or charge at low electricity prices and supply power to the home at peak times to save home electricity costs.

     

what is V2G technology? In short, it is based on two-way charging piles, combined with energy management systems and cloud platform intelligent scheduling technology, and connected to the power grid dispatching system to realize the intelligent two-way transmission of electrical energy between the power grid and vehicles, meeting the purposes of vehicle transportation, new energy access, and stable control of the power grid.

Application scenarios

  1. Grid-side V2G peak shaving

     Adaptation advantages: Supports charging during off-peak hours and discharging during peak hours (100kW discharge power), helping the power grid balance loads; can be connected to the grid dispatching platform, suitable for power companies and new energy vehicle companies to build "virtual power plants"; covers long-tail keywords such as "grid peak shaving V2G charging piles" and "virtual power plant bidirectional charging and discharging equipment".

  2. Home V2H emergency backup

     Adaptation advantages: IP54 protection allows installation on balconies/garages, with a temperature resistance range of -40℃~+75℃, suitable for both northern and southern regions; automatically switches to V2H mode during power outages, with 40kW power capable of supporting a refrigerator (0.8kWh/day) + air conditioner (1.5kWh/day) to work continuously for 3 days; covers "home V2H charging piles" and "power outage backup bidirectional fast charging piles".

  3. Outdoor V2L power supply (camping/emergency)

     Adaptation advantages: 5m cable + IP54 waterproof, suitable for campsites and outdoor construction; V2L mode can power electric drills (1.5kW), portable ovens (2kW), and emergency lighting, replacing fuel generators; covers "outdoor V2L charging piles" and "camping vehicle-mounted power supply equipment".

 

Documentation Resource Library
Public.
High-performers fast charger selection catalog
Catalogue
English
FAQ
Q: Which electric vehicles are compatible with this bidirectional charger?
A:

It supports GBT/CCS1/CCS2/CHAdeMO/Tesla connectors, compatible with most EV models (e.g., BYD, Tesla, Volkswagen).

Q: How long can the V2H mode power a home?
A:

With 40kW output, it can power a family (refrigerator + lighting + router) for 3-5 days, or with air conditioning for 1-2 days.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.