Sauka
Akwai sauka ce ta hasa da wurin da ake kula da ring main units, musamman wani air-insulated intelligent vacuum ring main unit.
Bayanin Sana'o'i
Ring main unit shine sarrafa mai sana'a da take kula da high-voltage switchgear a cikin yankin metal ko kuma a bincike ita a kan interval-type ring main power supply unit. Tana ci gaba da tashar busbars na gabashin feeder cabinets, da kuma mafi muhimmanci na shi sun hada da load switches da fuses. Ana da shugaban tsari, adadin kadan, kudin kadan, masu parametolin da ba da kyau, da kuma dalilin cin bayanai.
Air-insulated ring main units (ko kuma semi-insulated ring main units) sun yi amfani da dry air a matsayin insulation da kuma arc-extinguishing medium. Kyakkyawar da suka fi koyar da SF6 gas, ba suka samu nasarorin al'adun jiki. High-voltage live switches suna cikin air chamber mai kyau da ya kasa, da kuma tsari da ya kasa, ba zan iya canza da harkokin al'umma, saboda haka ana iya amfani da su a wurareen da dama, salt-alkali regions, da kuma wurareen da ke da ruwa.
A tushen da yake, air-insulated ring main units suna da amfani da combination forms kamar load switch-disconnector, load switch-high-voltage fuse, da kuma vacuum circuit breaker-disconnector. Unit cabinets zai iya amfani da su a kafin kafin ko kuma binciken da dama. Amma akwai wasu abubuwa da ba da shiga:
Idan an bincika, yadda ake yi aiki tana da shiga da relay and instrument compartment kawai, don haka an bukata da yin buƙaci da yin nuna aiki da kisan mutane, wanda ya haɗa da cost.
Yadda ake fitar da jiki a cikin cabinet ba a iya tabbatar da shi daidai: Yadda ake amfani da air circulation kawai ba a iya fitar da jiki daidai, saboda haka structure na ventilation hole mai sauƙi tana da shiga da inganta ruwa, wanda ya haɗa da electrical safety. Yana buƙata da yin ƙarin.
Bayanin Utility Model
Zabubbukan
Wajen haɗa da abubuwan da aka ƙoƙari a tushen da yake, utility model ya ba da air-insulated intelligent vacuum ring main unit, wanda ya haɗa da:
Kalmomin layout da za su iya yanke fitaccen busbar combination functionality.
Nunan bayanai na aiki a lokacin, taimakawa da ƙarin intelligent management levels, da kuma ƙara cost.
Ƙarin fitar da jiki a lokacin da ma inganta ruwa, tun dace da electrical safety da energy efficiency.
Salamin Sana'o'i
Air-insulated intelligent vacuum ring main unit tana da cabinet body da cikin shi akwai internal structure kamar haka:
Muhimmanci Functional Areas and Components
Cabinet body tana da busbar compartment, relay and instrument compartment, switch compartment, da kuma cable compartment:
Busbar Compartment: Tana da busbars, first temperature sensor, da kuma fan set electrically connected to a PLC controller.
Relay and Instrument Compartment: Tana nan a kusa da busbar compartment, tana da relays.
Switch Compartment: Tana nan a kusa da busbar compartment, tana da load switch set, second temperature sensor, da kuma humidity sensor (humidity sensor tana nan a kusa da first partition plate da ya kasa data storage module). Load switch set tana kasa busbar compartment via insulator set comprising three interval insulators and tana kasa fuses, operating mechanism, da kuma current transformer. Frame tana nan a kusa da current transformer da cabinet body.
Control compartment da air chamber tana nan a kusa da switch compartment:
Control Compartment: Tana nan a kusa da relay and instrument compartment da air chamber, tana da circuit board da PLC controller. Circuit board tana integrate data storage module, wireless transmission module, da kuma wireless reception module. Data storage module tana kasa relays, first temperature sensor, second temperature sensor, da kuma wireless transmission module. Wireless reception module tana kasa PLC controller.
Air Chamber: Tana nan a kusa da switch compartment via first partition plate, da kuma kusa da air inlet mesh facing cabinet body. First partition plate tana da return air outlet da supply air outlet, tana da first fan da second fan respectively (both electrically connected to the PLC controller). First fan tana kasa moisture absorption plate, tana nan a kusa da second fan da air inlet mesh.
Cable Compartment: Tana da interconnected earthing switch, lightning arrester, da kuma cable.
Cabinet Body and Profile Structure
Second partition plates tana nan a kusa da busbar compartment da relay & instrument compartment/switch compartment, da kuma a kusa da switch compartment da control compartment/cable compartment.
Cabinet body tana da several riveted frame plates. Both frame plates da frame tana da profile body:
Four corners of profile body tana da plug-in blocks. Outer wall of plug-in block tana da inclination relative to profile body, tana da first through hole inside and limit plates on both sides.
Center of profile body tana da second through hole. Top and bottom cross-section tana da isosceles trapezoid, da kuma kusa da concave arcs.
Both sides of profile body tana da concave arc plates, tana da several waist-shaped mounting holes.
Fadada
Structural Advantages: Profile body tana da plug-in blocks da concave arc plates, along with first through hole da specially shaped second through hole, tana da shugaban tsari da stability, da kuma ƙara wall thickness. Waist-shaped mounting holes tana taimakawa da quick assembly da subsequent sensor embedding/wiring. Overall structure tana da nau'in, compact, da kuma easy to assemble.
Layout Optimization: Relay and instrument compartment, control compartment, da kuma air chamber tana nan a kusa, combined and connected with switch compartment da busbar compartment, effectively expanding busbar functions, avoiding wiring confusion, da kuma providing high space utilization.
Intelligent Control:
Data storage module tana send circuit status and environmental data collected by relays, temperature sensors (first and second), da kuma humidity sensor in real-time via wireless transmission module, facilitating integrated monitoring of connected cabinets, improving intelligent management, da kuma ƙara cost.
After wireless reception module receives control signal, PLC controller tana activate as needed: fan set for internal circulation heat dissipation, or second fan to draw in external air through moisture absorption plate for external circulation cooling. When temperature is low, only first fan can be activated, using hot air from switch compartment to dehumidify moisture absorption plate. This enhances energy efficiency, avoids moisture introduction, and balances electrical safety with energy savings.
Na'urar Implementation Mode
I. Cabinet Structure and Core Components
Functional Area Division
Cabinet interior tana da busbar compartment, relay and instrument compartment, switch compartment, cable compartment, control compartment, da kuma air chamber. Each area tana nan a kusa da partition plates, da kuma clear functions da ba da interference.
Busbar compartment tana nan a kusa da upper part, da kuma relay and instrument compartment a kusa, da kuma switch compartment a kusa. One side of switch compartment tana nan a kusa da control compartment da air chamber, while other side tana nan a kusa da cable compartment.
Core Components of Each Area
Busbar Compartment: Tana da busbars, first temperature sensor, da kuma fan set electrically connected to PLC controller.
Relay and Instrument Compartment: Tana da relays for collecting equipment operating status (e.g., current, voltage, power).
Switch Compartment: Tana da load switch set, second temperature sensor, da kuma humidity sensor. Load switch set tana kasa busbar compartment via insulator set (with three interval insulators) and tana kasa fuses, operating mechanism, da kuma current transformer. Frame tana nan a kusa da current transformer da cabinet body.
Control Compartment: Tana da circuit board da PLC controller. Circuit board tana integrate data storage module, wireless transmission module, da kuma wireless reception module. Data storage module tana kasa relays, first temperature sensor, second temperature sensor, da kuma humidity sensor. Wireless reception module tana kasa PLC controller.
Air Chamber: Tana nan a kusa da switch compartment via first partition plate, da kuma kusa da air inlet mesh. First partition plate tana da return air outlet da supply air outlet, tana da first fan da second fan respectively (both electrically connected to PLC controller). First fan tana kasa moisture absorption plate, tana nan a kusa da second fan da air inlet mesh.
Cable Compartment: Tana da interconnected earthing switch, lightning arrester, da kuma cable.
Cabinet Body and Profile Structure
Cabinet body tana form by riveting several frame plates. Both frame plates da frame tana use profile body.
Four corners of profile body tana da plug-in blocks. Outer wall of plug-in block tana da inclination relative to profile body, tana da first through hole inside and limit plates on both sides. Center tana da second through hole; top and bottom cross-section tana da isosceles trapezoid, da kuma both sides tana da concave arcs. Both sides of profile body tana da concave arc plates tana da several waist-shaped mounting holes.
II. Working Principle and Advantages
Assembly Method
Profile bodies tana achieve quick connection via plug-in blocks with limit plates, and tana then riveted and fixed using corner connecting pieces through waist-shaped mounting holes on concave arc plates. Assembly process tana convenient da stable, also providing shock resistance, lower cost and weight, da kuma ease of transportation.
Operation and Intelligent Control Process
Busbar compartment tana connect multiple ring main units. Load switch set tana kasa busbar compartment via insulator set. Fuse tana disconnect circuit by melting its element when current exceeds limit. Operating mechanism tana perform closing and opening operations. Current transformer tana proportionally convert large primary current to small secondary current, protecting measurement circuit, and transmitting signals to earthing switch, lightning arrester, da kuma cable in cable compartment.
Relays tana collect equipment operating status and transmit it to data storage module on circuit board. This module tana also store temperature signals from first and second temperature sensors and humidity signal from humidity sensor. These tana then sent in real-time via wireless transmission module to base station or control terminal for remote monitoring.
Control terminal tana can send commands to PLC controller via wireless reception module, or PLC controller tana make automatic judgments: When heat dissipation tana needed, tana activate fan set for internal circulation heat dissipation, or start second fan to draw air through inlet mesh, dehumidify it via moisture absorption plate, and supply it into cabinet for external circulation heat dissipation. When temperature does not meet condition for starting second fan, only first fan tana be activated to dehumidify moisture absorption plate, reducing energy consumption while avoiding moisture introduction.
Core Advantages
Real-time monitoring and intelligent control of cabinet's temperature, humidity, and equipment operating status tana achieved. This ensures electrical safety while reducing energy consumption by activating equipment on demand, balancing practicality and energy efficiency.