Tá an t-úsáid teicneolaíochta seo gaol le réimse an chuid mhéide ring, go háirithe cistin ghuthaíoch shuntasach ar bhonn aer.

Teicneolaíocht Comhaimseartha

Is úirlis deilgtheach í an cistin ghrinn a dúnann roghnacha deilgtheacha ar bhonn ard-voltach i gcaisín meite nó a chumhachtóidh i gcaisín grinn. Tá an córas bunaithe ar nascadh busbars na mbuiséad éagsúla, agus is é a lár a dhéanann saincheisteanna deilgtheacha agus fiosrúcháin. Tá struchtúr simplí, méid bheag, costas íseal, paraiméad cumhachta maith, agus slándacht ard aici.

Úsáideann cistí ghrinne airshluaite (má tá siad ina cistí ghrinne airshluaite) aer scartha mar mheadhan sluaite agus smál-díchúiseoireachta. Is fearr a gcumas ná SF6 gas gan polaíocht comhshaoil a chur ar siúl. Tá na scuabanna beatha ard-voltacha suite i gcaomhnú aer faoi bhaintle constand nach bhfuil tionchar atmaisféarach air, agus is oiriúnach iad do réimsí speisialta cosúil le páirceanna, réimsí sal-alkali, agus áiteanna madraí.

Sa theicneolaíocht reatha, úsáideann cistí ghrinne airshluaite formlacha comhbhunaithe cosúil le scuab deilgtheach-scuirteoir, scuab deilgtheach-fuse ard-voltach, agus scuab guthaíoch-scuirteoir. Is féidir le caibidí a úsáid go neamhspleách nó a chumhachtú go saoránach. Ach tá na lochtanna seo leanas ann:

  1. Nuair a chumhachtófar, taispeánfar stádas oibriúcháin amháin trí chuomhachtóireacht relay agus cuibhreann an uirlis, ag iarraidh seiceálacha rialta láithreach agus déantúsaireachta, rud a chuirfí costas ardh ar.

  2. Tá sé deacair an t-ealaíontacht a réiteach go héifeachtach sa chaibid: Tá brón ar an ealaíontacht a chur amach go héifeachtach trí chomhluadar aer inmheánach, agus is féidir struchtúr simleach oscailte aer a chur isteach ar mhórán uisce, ag cur isteach ar slándacht deilgtheach. Tá feabhas aige go ginearálta.

Ábhar an Úsáid Teicneolaíochta

Príomhaidhm

Aiming at the defects of the existing technology, the utility model provides an air-insulated intelligent vacuum ring main unit, aiming to achieve:

  • A rational layout to expand busbar combination functionality.

  • Real-time monitoring of the operating status, improving      intelligent management levels, and reducing maintenance costs.

  • Optimized heat dissipation performance while avoiding moisture      introduction, balancing electrical safety and energy efficiency.

Solú an Fheidhme

Comprised of a cabinet body with the following internal structure:

  1. Core Functional Areas and Components

    • The cabinet body includes a busbar compartment, a relay and       instrument compartment, a switch compartment, and a cable compartment:

    • Busbar Compartment:       Contains busbars, a first temperature sensor, and a fan set electrically       connected to a PLC controller.

    • Relay and Instrument Compartment: Located on one side of the busbar compartment, housing       relays.

    • Switch Compartment:       Located at the bottom of the busbar compartment, housing a load switch       set, a second temperature sensor, and a humidity sensor (the humidity       sensor is located on one side of a first partition plate and connected to       a data storage module). The load switch set is connected to the busbar       compartment via an insulator set comprising three interval insulators and       is connected to fuses, an operating mechanism, and a current transformer.       A frame is provided between the current transformer and the cabinet body.

    • A control compartment and an air chamber are located on one       side of the switch compartment:

      • Control Compartment: Situated between the relay and instrument compartment and        the air chamber, housing a circuit board and the PLC controller. The        circuit board integrates the data storage module, a wireless        transmission module, and a wireless reception module. The data storage        module is connected to the relays, the first temperature sensor, the        second temperature sensor, and the wireless transmission module. The        wireless reception module is connected to the PLC controller.

      • Air Chamber: One side is connected        to the switch compartment via the first partition plate, and the other        side has an air inlet mesh facing the cabinet body. The first partition        plate is provided with a return air outlet and a supply air outlet,        equipped with a first fan and a second fan respectively (both electrically        connected to the PLC controller). The first fan is connected to a        moisture absorption plate, which is located between the second fan and        the air inlet mesh.

    • Cable Compartment:       Houses an interconnected earthing switch, lightning arrester, and cable.

  2. Cabinet Body and Profile Structure

    • Second partition plates are provided between the busbar       compartment and the relay & instrument compartment/switch       compartment, and between the switch compartment and the control       compartment/cable compartment.

    • The cabinet body is composed of several riveted frame plates.       Both the frame plates and the frame use a profile body:

      • The four corners of the profile body are provided with        plug-in blocks. The outer wall of the plug-in block is inclined relative        to the profile body, with a first through hole inside and limit plates        on both sides.

      • The center of the profile body has a second through hole. The        cross-section of its top and bottom is an isosceles trapezoid, and both        sides are concave arcs.

      • Both sides of the profile body are provided with concave arc        plates, which have several waist-shaped mounting holes.

Forbhaisí

  1. Forbairt Struchtúrach: An      profile body le plug-in blocks agus pláití arc concave, leis an      first through hole agus an second through hole a bhfuil form ar      leathanach, cinntíonn sé rigid agus stabilitate ard, agus laghdóidh sé      méid balla. Cabhróidh na cúlraí mount waist-shaped le cabhrú      riachtanach agus cuardach/wiring tar éis sin. Tá an struchtúr      iomlán nua-aimseartha, comhtháthach, agus éasca a chumhachtú.

  2. Leagan Forbraíte: Tá an      relay and instrument compartment, control compartment, and air chamber      distributed on the same side, combined and connected with the switch      compartment and busbar compartment, effectively expanding busbar      functions, avoiding wiring confusion, and providing high space      utilization.

  3. Úsáid Intileachta:

    • The data storage module sends circuit status and environmental       data collected by the relays, temperature sensors (first and second), and       humidity sensor in real-time via the wireless transmission module,       facilitating integrated monitoring of connected cabinets, improving       intelligent management, and reducing maintenance costs.

    • After the wireless reception module receives a control signal,       the PLC controller activates as needed: the fan set for internal       circulation heat dissipation, or the second fan to draw in external air       through the moisture absorption plate for external circulation cooling.       When the temperature is low, only the first fan can be activated, using       hot air from the switch compartment to dehumidify the moisture absorption       plate. This enhances energy efficiency, avoids moisture introduction, and       balances electrical safety with energy savings.

Mód Impleachta Mionsonraithe

I. Cabinet Structure and Core Components

  1. Functional Area Division

    • The cabinet interior includes the busbar compartment, relay       and instrument compartment, switch compartment, cable compartment,       control compartment, and air chamber. Each area is separated by partition       plates, with clear functions and no interference.

    • The busbar compartment is located in the upper part, with the       relay and instrument compartment on one side and the switch compartment       at the bottom. One side of the switch compartment sequentially has the       control compartment and the air chamber, while the other side is the       cable compartment.

  2. Core Components of Each Area

    • Busbar Compartment:       Contains busbars, the first temperature sensor, and the fan set       electrically connected to the PLC controller.

    • Relay and Instrument Compartment: Houses relays for collecting equipment operating status       (e.g., current, voltage, power).

    • Switch Compartment:       Equipped with the load switch set, the second temperature sensor, and the       humidity sensor. The load switch set is connected to the busbar       compartment via the insulator set (with three interval insulators) and is       connected to fuses, the operating mechanism, and the current transformer.       A frame is provided between the current transformer and the cabinet body.

    • Control Compartment:       Contains the circuit board and the PLC controller. The circuit board       integrates the data storage module, wireless transmission module, and       wireless reception module. The data storage module is connected to the       relays, the first temperature sensor, the second temperature sensor, and       the humidity sensor. The wireless reception module is connected to the       PLC controller.

    • Air Chamber: One side is connected       to the switch compartment via the first partition plate, and the other       side has the air inlet mesh. The first partition plate has a return air       outlet and a supply air outlet, equipped with the first fan and second       fan respectively (both electrically connected to the PLC controller). The       first fan is connected to the moisture absorption plate, located between       the second fan and the air inlet mesh.

    • Cable Compartment:       Houses the interconnected earthing switch, lightning arrester, and cable.

  3. Cabinet Body and Profile Structure

    • The cabinet body is formed by riveting several frame plates.       Both the frame plates and the frame use the profile body.

    • The four corners of the profile body have plug-in blocks. The       outer wall of the plug-in block is inclined relative to the profile body,       with a first through hole inside and limit plates on both sides. The       center has a second through hole; its top and bottom cross-section is an       isosceles trapezoid, and both sides are concave arcs. Both sides of the       profile body also have concave arc plates with several waist-shaped       mounting holes.

II. Modh Oibre agus Forbhaisí

  1. Modh Cumhachta

    The profile bodies achieve quick connection via the plug-in blocks with limit plates, and are then riveted and fixed using corner connecting pieces through the waist-shaped mounting holes on the concave arc plates. The assembly process is convenient and stable, also providing shock resistance, lower cost and weight, and ease of transportation.

  2. Modh Oibre agus Proiseas Úsáid Intileachta

    • The busbar compartment connects multiple ring main units. The   load switch set connects to the busbar compartment via the insulator set. The fuse disconnects the circuit by melting its element when current       exceeds the limit. The operating mechanism performs closing and opening  operations. The current transformer proportionally converts a large  primary current to a small secondary current, protecting the measurement  circuit, and transmits signals to the earthing switch, lightning  arrester, and cable in the cable compartment.

    • The relays collect equipment operating status and transmit it   to the data storage module on the circuit board. This module also stores       temperature signals from the first and second temperature sensors and the       humidity signal from the humidity sensor. These are then sent in  real-time via the wireless transmission module to a base station or  control terminal for remote monitoring.

    • The control terminal can send commands to the PLC controller  via the wireless reception module, or the PLC controller can make       automatic judgments: When heat dissipation is needed, it activates the       fan set for internal circulation heat dissipation, or starts the second       fan to draw air through the inlet mesh, dehumidify it via the moisture  absorption plate, and supply it into the cabinet for external circulation  heat dissipation. When the temperature does not meet the condition for       starting the second fan, only the first fan can be activated to       dehumidify the moisture absorption plate, reducing energy consumption    while avoiding moisture introduction.

  3. Forbhaisí Bunúsacha

    Real-time monitoring and intelligent control of the cabinet's temperature, humidity, and equipment operating status are achieved. This ensures electrical safety while reducing energy consumption by activating equipment on demand, balancing practicality and energy efficiency.


Tabhair leithrinn agus coiméide an údar!

Moltaigh

Anailís ar Fháilte agus Réitíochtaí do 17.5kV Ring Main Units i Néigteacháin Díolacháin
Mar sin é an forbartha sóisialta agus an méideachú ar chaolchoiméide na ndaoine, tá an t-íoca don rialtas idirnáisiúnta ag ardú go leanúnach. Chun a chinntiú go mbeidh an córas gréasáin reatha ina chumas, is gá píobáin díleála a thógáil go réasúnta bunaithe ar an bhfíric. Ach, le linn oibriú na ngréasáin díleála, tá ról an-tábhachtach ag aonaid príomhchiorcail 17.5kV, mar sin, is go suntasach an tionchar atá ag teipthe. Ag an bpointe seo, is gá réitigh réasúnta agus éifeachtúla a ghlacadh bunait
12/11/2025
Conas a sholáthar DTU ar IEE-Business N2 Insulation ring main unit?
DTU (Distribution Terminal Unit), teirmeán deilbhíochta in iarmháin sónraíochta leictreach, is é uirlis deilbhíochta atá suite sa stáisiún scuab, seomraí díolacháin, N2 Insulation ring main units (RMUs), agus stáisiúin deilbhíochta bosca. Is é a chreideann an nasc idir uirlisí príomha agus an príomhstáisiún um shónraíocht deilbhíochta. RMUs N2 Insulation sine nach bhfuil DTUs orthu ní féidir leo cumarsáid a dhéanamh leis an príomhstáisiún, agus ní mheastar go mbíonn siad ar a gcumas sónraíocht a
12/11/2025
Aonad Mórthimpeachta Iomchuir Idirghnáthaithe i gCóras Uathoibríochta 10kV
I ríomhchúiseach úsáid teicneolaíochtaí eolais, is féidir leis an gcomhcheilgthiúinthe inbhuanaithe i mbunú ar chonairteoireacht 10kV níos mó a bheith cabhrach chun an leibhéal forbartha 10kV conairteoireacht eolais a fheabhsú agus chun staidéar a dhéanamh ar chinnteachas na bunú 10kV conairteoireacht eolais.1 Cúlra Taighde Comhcheilgthiúinthe Inbhuanaithe.(1) Úsáideann an comhcheilgthiúinthe inbhuanaithe teicneolaíochtaí níos cothroime, lena n-áirítear ach gan a bheith teoranta do theicneolaíoc
12/10/2025
Dearbhadhúcháin Óptach ar Ghais-Insulated Switchgear do Thíortha Ard-altaithe
Is iad na ranná gas-chosúil ring main a bhfuil iad comhacta agus leathnaithe in ann chun córais uathoibríochta rialacháin fhuinnimh meánvoltage. Tá na húirlí seo á n-úsáid do thaispeántas fuinneamha anfhaisce 12~40.5 kV, córais fuinnimh dháshléibh, agus feidhmchláir fuinnimh teirmeach, ag obair mar úirlí rialú agus cosanta fuinneamha eilectraí. Is féidir leo a shuiteáil i stáisiúin spásach.Trí fuinneamh eilectraí a díol agus a srianta, cinntíonn siad oibriú stabhail córas fuinnimh. Úsáideann na
12/10/2025
Seol fiosrúchán
+86
Cliceáil chun comhad a uaslódáil
Íoslódáil
Faigh an tApliú IEE Business
Úsáid an t-aip IEE-Business chun eochair uirlis a aimsiú déantar réiteach a fháil nasc le saineolaithe agus glacadh páirte i gcothromhachtú tionscail ar bith áit ar bith go láidir tacú le forbairt do thionscadal forbartha agus gnó