Seirbhísí deisiú scáthlaí mheicteacha cáblái airgidromhaíneacha

Felix Spark
Felix Spark
Réimse: Meathú agus Bainneanas
China

I. Fheidhmeanna Cúlra Meaitice agus Gá le Deisiú

Is cúlra meaitice struchtúr cosanta áitiúil é atá leagtha amach lasmuigh den scuabadán comhartha i gcáblacha high-voltage, lena n-áirítear cúlra lead, alúimín, agus armú dréime. Príomhfheidhmeanna a bhfuil aige ná cosaint meicniúil (n-aontú le locht agus brú), cosaint eileachtrach-cineálach (scuabadh uisce agus cothromóidí talún), scuabadh eileachtrach-mhaighnéadach (laghdú ar scuabadh eileachtrach ar an timpeallacht), agus tairiscint slí grunda (cinntiú sráide fhuafach go sábh). Más gortaithe é an cúlra meaitice, d'fhéadfadh sé a bheith mar thoradh air sin go mbeadh comhartha sa scuabadán, dochar dátheangachas réigiúnach, nó fiach faoi dhó agus cáblacha a bhriseadh. Mar sin, is criticiúil deisigh chruinn ar son ráitis éagsúla damáiste chun cinntiú oibriú slán fada théarmach na gcórais cáblacha.

high-voltage cable.jpg

II. Diagnóis Locht agus Méideoireacht Roimh Deisiú

(A) Aitheantas Cineál Damáiste

  • Damáiste Meicniúil: In ainneoin lochtaí, spáltaí, nó puncáil sa chúlra, go minic as roinnt méadach meicniúil nó puncáil greann le linn seoladh, nó briseadh nascúcháin de bharr suíochán bunúsach fhadtréimhseach.

  • Coróisi Eileachtrach-Cineálach: Is féidir le siúir cheadaireachta sa talamh nó i gcúrsaí acídach/bacaidh coróisi eileachtrach-cineálach a dhéanamh ar an chúlra, léirithe trí thuar oscailte, meite, puncáil, agus tuar coróisi bán/glas (cúlra alúimín) nó sulfíd dubh (cúlra lead).

  • Damáiste Seoighe Árdteorainne: Úsáid fhadtréimhseach forbrú a dhéanann teorainneacht an chúlra a laghdú, tar éis sin crácáil agus scuabadh, go minic a aimsítear ag comhcheangal nó in áiteanna nach raibh éifeachtach é an t-easpónadh teasa.

(B) Úsáid Teicnící Méideoireachta

  • Scrúdú Radharcach: Úsáid endoscóip nó íomháire theasach infra-rud toscrach chun an taisce chúlra a fheiceáil, ag tabhairt aird ar aon phointe damáiste sna mórtas agus pointe theasa.

  • Tástáil Taisce Cúlra: Cuir teasc DC (10 kV ar feadh 1 nóiméad) chun taisce chúlra a thástáil. Mionsonracht neamhchoitianta sa sráid (> 10 μA) léiríonn damáiste.

  • Mearsú Dischaise Páirteach: Úsáid sensora sráide ard-freastala (HFCT) chun sainní dischaise páirteach a bhaint amach ag pointe damáiste, le cruinneas suíomh bainte amach go dtí ±0.5 m.

  • Méideoireacht Coróisi Talamh: Baint samplaí talaimh ón timpeallacht chun taiscéadach cáblacha a thástáil ar pH, maolach clóride, agus láidreacht siúir cheadaireachta, ag soláthar bonn do roghnú ábhair deisiú.

cable.jpg

III. Roghnú Ábhar agus Uirlisí Deisiú

(A) Ábhair Deisiú Príomha

  • Ábhair Athsholú Cúlra Meaitice:

    • Sleeve Comhghlacáil Alúimín: Oiriúnach do sheoladh alúimín, le ductility agus cosaint coróisi maith. Caithfidh sé a oibriú le trastomhas cáblach (tolerance ≤ ±0.5 mm).

    • Teip Leoid-Tin: Úsáidtear chun athsholú cúlra lead, pointe teasa íseal (~183°C), héasta téarmaill, ag freastal ar riachtanais GB/T 12706.2 (lód lead ≥ 99.9%).

    • Tuile Corrugated Níodréime: Do dhamage armú dréime, déanta as níodréime 304, mearachta balla ≥ 0.8 mm, le cosaint brú agus stress talún.

  • Ábhair Cosanta agus Sealú:

    • Heat-Shrink Tubing Cross-Linked Polyethylene (XLPE): Scuabadh ag 120–140°C, ratio scuabadh ≥ 2:1, tionscadal briseadh ≥ 25 kV/mm, ag iarraidh adheseive hot-melt le haghaidh sealú.

    • Silicone Rubber Cold-Shrink Tubing: Ag brath ar elastic recovery le haghaidh sealú, gan teas riachtan, oiriúnach do spásanna curtha, hardnes Shore 60 ± 5 Shore A, tanδ ≤ 0.003 (20°C, 50 Hz).

    • Butyl Rubber Sealing Tape: Úsáidtear mar chéim sealú cabhrach, láidreacht tear ≥ 3 MPa, extension at break ≥ 400%, cosaint seamróda retain ≥ 80% performance tar éis 100°C × 168 h thermal aging.

  • Ábhair Cosaint Coróisi:

    • Zinc-Aluminum Alloy Sacrificial Anode: Do thirim coróisi soil ard, anode purity ≥ 99.5%, current density ≥ 15 mA/m², design life ≥ 20 years.

    • Polyvinyl Chloride (PVC) Corrosion-Resistant Tape: Thickness ≥ 0.4 mm, tensile strength ≥ 18 MPa, environmental stress cracking resistance (ESCR) ≥ 1000 h.

(B) Uirlisí Speisialtóireachta

  • Uirlisí Priobháideacha: Grindéir gonta (le wheel alumina 80-grit), brush dréime, ethanol gan uisce, scrapper níodréime (do tharraingt products coróisi).

  • Uirlisí Formála: Crimping tool hidraoil (range 60–200 mm²), heat gun (range teasa 50–600°C), torch speisialtóireachta (flame temperature ≤ 300°C).

  • Uirlisí Test: Megohmmeter (2500 V, range 0–10000 MΩ), double-arm bridge (contact resistance measurement, accuracy ±0.1 μΩ), ultrasonic thickness gauge (resolution 0.01 mm).

cable.jpg

IV. Modhanna Deisiú Cruinn Bunaithe ar Chineál Damáiste

(A) Deisiú Damáiste Meicniúil (Sampla Cúlra Alúimín)

  • Preparation Area Damáiste

    • Úsáid grindéir gonta chun an chúlra damáiste a oscailt axially, le cut length 5 times the damage diameter (minimum ≥ 100 mm), exposing clean insulation shield.

    • Remove burrs from sheath edges with a stainless steel scraper, sand to metallic luster, clean oil with ethanol, and dry for ≥ 15 min.

  • Metallic Sheath Restoration

    • Select an aluminum alloy compression sleeve with inner diameter 1 mm larger than cable outer diameter, uniformly coat inner wall with conductive grease (nickel-based filler, volume resistivity ≤ 5×10⁻⁴ Ω·cm).

    • Slide the sleeve over the damaged area, use a Staggered Crimping method, crimp from center to ends. After crimping, hexagonal opposite-side deviation ≤ ±0.1 mm, contact resistance ≤ 20 μΩ.

  • Sealing and Anti-Corrosion Treatment

    • Wrap butyl rubber sealing tape with 50% overlap, forming a sealing layer ≥ 3 mm thick, extending ≥ 50 mm beyond undamaged sheath on both ends.

    • Install heat-shrink tubing, heat gradually from center to ends (120°C → 140°C) to avoid bubbles. After cooling, check uniform shrinkage (post-shrinkage wall thickness ≥ 2 mm).

    • Wrap PVC corrosion-resistant tape externally in a half-overlap spiral, secure ends with stainless steel straps (torque 15–20 N·m).

(B) Deisiú Coróisi Eileachtrach-Cineálach (Cúlra Comhbhun Armú Dréime + Lead)

  • Corrosion Product Removal

    • Use sandblasting (quartz sand 80–120 mesh, pressure 0.4–0.6 MPa) to remove rust from steel armor, exposing gray-white metal base, surface roughness Sa2.5 grade.

    • Trim lead sheath corrosion area with a lead plane, forming a smooth transition with slope ≥ 1:5 to avoid stress concentration.

  • Sacrificial Anode Protection

    • Symmetrically install 2 zinc-aluminum alloy anodes (100 mm × 50 mm × 10 mm) on both sides of the repair section, connected to steel armor via copper braid (cross-section ≥ 16 mm²), welded (lap length ≥ 30 mm, welding current 120–150 A).

    • Fill gap between anode and cable sheath with petroleum jelly, encapsulate externally with high-density polyethylene (HDPE) housing to ensure full soil contact.

  • Dual Sealing Structure

    • Inner layer: cold-shrink silicone rubber tubing, inner wall coated with semiconductive water-blocking gel (volume resistivity 10–100 Ω·cm). Maintain at room temperature for 24 h after recovery for curing.

    • Outer layer: pour epoxy resin (E-51 type, curing agent T-31, ratio 100:25), mold sealed at 0.2 MPa pressure, cure ≥ 48 h at 25°C. Post-cure Shore hardness ≥ 85 Shore D.

(C) Deisiú Cracáil Seamróda (Cáblach XLPE Insulated)

  • Crack Area Reinforcement

    • Cut a V-groove along the crack direction (depth 1/3 of sheath thickness, angle 60°), fill with heat-resistant silicone rubber (temperature rating ≥ 180°C, tear strength ≥ 15 kN/m), level with scraper, cure at room temperature for 2 h.

    • Wrap glass fiber cloth (0.2 mm thick, 16×16 threads/cm), impregnate with epoxy resin (solid content ≥ 70%) to form a reinforcement layer. Tensile strength ≥ 200 MPa after curing.

  • Heat Dissipation Optimization

    • Install aluminum heat sinks (1.5 mm thick, fin spacing 5 mm) externally on the repair section, bonded to sheath with thermal grease (thermal conductivity ≥ 1.5 W/(m·K)) to reduce local temperature rise (≤ 5°C).

    • Monitor operating temperature with infrared thermal imager, ensuring temperature difference from undamaged section ≤ 2°C.

V. Rialacha Rialú Calaitheachta agus Stándairde Glacadh

(A) Test Key Parameters

  • Electrical Performance: Sheath insulation resistance ≥ 1000 MΩ (2500 V megohmmeter), partial discharge ≤ 5 pC (at 1.73U₀ voltage).

  • Mechanical Performance: Impact resistance of repair section ≥ 10 J (at -30°C), bending radius ≥ 20 times cable outer diameter (no obvious deformation).

  • Sealing Performance: After immersion test (room temperature, 24 h), sheath leakage current change rate ≤ 10%, no bubbles or water ingress.

(B) Long-Term Reliability Verification

  • Accelerated Aging Test: Place repair sample in thermal aging chamber (135°C × 1000 h), after removal insulation resistance retention ≥ 80%, tensile strength degradation ≤ 20%.

  • Soil Burial Test: Simulate actual laying environment, buried depth 1 m, duration 1 year, check for no corrosion perforation or seal failure.

VI. Rialacha Oibriú Sábháilte

  • Power-Off Work Requirements: Follow "power-off - voltage test - grounding wire installation" procedure before repair. Hang "Do Not Close" warning signs on cable terminations, set safety barriers (distance ≥ 8 m) within work radius.

  • Hot Work Management: When using torches or welding, equip dry powder fire extinguishers (ABC type, capacity ≥ 4 kg), clear flammable materials within 3 m, assign a dedicated supervisor.

  • Personal Protective Equipment (PPE): Wear insulated gloves (35 kV rating), goggles, flame-resistant workwear. Use safety harness (static load test force 2205 N, hold 3 min without break) for work at heights (≥ 2 m).

Tabhair leithrinn agus coiméide an údar!
Moltaigh
Treoir Fadhbanna Coitianta & Solúidí do 10kV RMU
Treoir Fadhbanna Coitianta & Solúidí do 10kV RMU
Fadhbanna Feidhmeáin agus Beartais do Aonaid Mórchiorcla 10kV (RMUs)Is feidhmeán deighineach é an aonad mórchiorcla 10kV (RMU) i ndúshlánuithe ar an ngnéasóireacht, ag baint úsáide as sé go príomha le haghaidh fógraíocht meánvoltaí. Le linn oibriú fíor, d'fhéadfadh fadhbanna éagsúla teacht chun cinn. Anseo thíos, na fadhbanna coitianta agus na beartais cuí.I. Fadhbanna Deileachta Ciorcal Coitianta Isteach nó Cabhlach MeasarthaD'fhéadfadh ciorcal coitianta isteach nó cabhlach measartha sa RMU a d
Echo
10/20/2025
Cineáltaí Briseadh Ciorcail Ardion & Treoir Fadhbanna
Cineáltaí Briseadh Ciorcail Ardion & Treoir Fadhbanna
High-Voltage Circuit Breakers: Classification and Fault DiagnosisIs mótarúilte iad briseoirí circe high-voltage sa chóras fuinnimh. Téann siad ar scor go tapa nuair a tharla deifir, ag cosaint ar tháirgeadh ó lódanna breise nó córais shorcha. Mar gheall ar oibriú fada éigríochta agus cúrsaí eile, d'fhéadfadh briseoirí circe fós a bheith faoi dhéanamh a bhfuil riachtanas orthu a diagnóis agus a dhiúltú.I. Raghaidh Briseoirí Circe High-Voltage1. De réir Suíomh Iastail: Indoor-type: Iastal i seomra
Felix Spark
10/20/2025
10 Cúram do Tháirgeadh agus Oibriú an Trafó!
10 Cúram do Tháirgeadh agus Oibriú an Trafó!
10 Cúrsaí a Bhfuil Fágáil Amach i Leith Socrú agus Oibriú an Trasnóir! Ná socrúigh an trasnóir riamh níos faide ná mar is gá—bíodh sé cosúil leis é a chur in ait thall nó i bpáirc mhór. Is minic a chuirtear isteach ar chábail agus feabhsaíonn sé fiachais líne, ach cuireann sé go háirithe deacracht ar bhainistíocht agus cothú. Ná roghnaigh an ciorcalacht trasnóra go foréigneach. Tá sé tábhachtach an ciorcalacht ceart a roghnú. Má tá an ciorcalacht ró-bheag, d'fhéadfadh an trasnóir a bheith tríthi
James
10/20/2025
Conas a choinneáil Trasnóirí Dúnta go Sábháilte?
Conas a choinneáil Trasnóirí Dúnta go Sábháilte?
Modholaí Meaitseála do Thraisfóirmeoirí Géar Cuir an traisfóirim ghearrach isteach i bhfeidhm, oscail an briseadh chiorcail ar thaobh ísle-spéile an traisfóirmeora atá le meaitseáil, baint amach an fuinneog stiúir, agus cuardach "NÁ DÚNGAÍ" ar uilleoga an briseadh. Oscail an briseadh chiorcail ar thaobh ard-spéile an traisfóirmeora atá le meaitseáil, dúng an briseadh talamhuín, scarraíoch an traisfóirim go lán, glasaigh an armadach ard-spéile, agus cuardach "NÁ DÚNGAÍ" ar uilleoga an briseadh. D
Felix Spark
10/20/2025
Seol fiosrúchán
Íoslódáil
Faigh an tApliú IEE Business
Úsáid an t-aip IEE-Business chun eochair uirlis a aimsiú déantar réiteach a fháil nasc le saineolaithe agus glacadh páirte i gcothromhachtú tionscail ar bith áit ar bith go láidir tacú le forbairt do thionscadal forbartha agus gnó