Surge Arresters for Shunt Compensation Capacitor Banks

  • Surge Arresters for Shunt Compensation Capacitor Banks

Key attributes

Brand ROCKWILL
Model NO. Surge Arresters for Shunt Compensation Capacitor Banks
Rated voltage 90kV
Rated frequency 50/60Hz
Series Y5WR

Product descriptions from the supplier

Description

Description

Surge Arresters for Shunt Compensation Capacitor Banks are specialized protective devices designed to safeguard shunt compensation capacitor banks in power grids. These capacitor banks, which improve power factor and voltage stability, are vulnerable to overvoltages from lightning, switching operations, or system faults. Installed in parallel with the capacitor banks, these arresters rapidly divert surge currents to the ground and clamp voltage spikes to safe levels, preventing damage to capacitors, switches, and associated components, thus ensuring the reliable operation of the capacitor banks and the overall grid.

Features

  • Bank-Specific Voltage Matching:Rated to match the voltage levels of shunt compensation capacitor banks, ensuring they provide precise protection without causing unnecessary energy loss or interference with the banks’ reactive power compensation function.

  • High Surge Handling Capacity:Designed to absorb large amounts of energy from severe transients, such as those from direct lightning strikes or capacitor bank switching surges, effectively mitigating the impact to protect capacitor elements from breakdown.

  • Fast Response to Transients:Equipped with high-performance metal oxide varistors (MOVs) that respond in microseconds to overvoltage events, critical for capacitor banks which are highly sensitive to voltage spikes even of short duration.

  • Resistance to Harmonic Stresses:Able to withstand harmonic currents and voltages commonly present in grids with shunt capacitors, ensuring stable performance without degradation from long-term exposure to harmonic distortion.

  • Durable Environmental Protection:Housed in robust materials like composite silicone rubber or porcelain, offering strong resistance to moisture, pollution, UV radiation, and extreme temperatures, suitable for both indoor and outdoor installations.

  • Low Leakage Current:Maintain minimal leakage current during normal operation, reducing power loss and preventing excessive heating, which helps maintain the efficiency of the capacitor bank system.

  • Compatibility with Bank Configurations:Designed to integrate seamlessly with various shunt capacitor bank configurations, including single-star, double-star, or delta arrangements, adapting to different grid requirements.

  • Compliance with Industry Standards:Meet international standards such as IEC 60099-4 and IEEE C62.11, ensuring they undergo rigorous testing for reliability, safety, and performance, compatible with global power system setups.

Model

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Voltage Residual (Switching Impulse)

Voltage Residual (Nominal Impulse)

Current Residual Voltage

Current - Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times






(Peak Value

(Peak Value

(Peak Value

(Peak Value


Y5WR1-51/134W

51

35

40.8

73

105

134

154

500

1256

Y5WR1-55/140W

55

35

42

82

119

140

161

500

1256

Y5WR1-84/221W

84

66

67.2

121

176

221

265

700

2750

Y5WR1-90/236W

90

66

72.5

130

190

236

271

700

2750

Y10WR1-48/140W

48

35

30

85

105

140

149

1500

1430

Y10WR1-51/140W

51

35

30

85

105

140

149

2000

1430

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.