Brand ROCKWILL
Model NO. Surge Arresters for AC Filters
Rated voltage 145kV
Rated frequency 50/60Hz
Series Y10W
Description

Description

Surge Arresters for AC Filters are specialized protective devices designed to safeguard AC filter systems in power grids, particularly in high-voltage transmission and distribution networks as well as converter stations. These arresters are installed in conjunction with AC filters, which are responsible for mitigating harmonic currents and improving power quality. They effectively suppress transient overvoltages that may occur in AC filter circuits due to lightning strikes, switching operations, system faults, or harmonic resonance. By rapidly diverting surge currents to the ground and clamping the voltage to a safe level, Surge Arresters for AC Filters prevent damage to filter components such as capacitors, reactors, and resistors, ensuring the stable operation of the AC filter system and thus maintaining the overall power quality and reliability of the power grid.

Features

  • Optimized for AC Filter CircuitsTailored to the specific electrical characteristics of AC filter systems, including the presence of harmonic frequencies and unique impedance properties. They are designed to handle the particular overvoltage scenarios that arise in these circuits, providing precise and effective protection without interfering with the normal filtering function.

  • Excellent Harmonic ResilienceCapable of operating stably in environments with high harmonic content. The internal components, especially the metal oxide varistors (MOVs), are designed to withstand the stress caused by harmonic currents and voltages, ensuring reliable performance even in the presence of significant harmonic distortion.

  • Rapid Response to TransientsEquipped with high-performance MOVs that have an ultra-fast response time to transient overvoltages. This quick reaction is crucial in AC filter systems, where even short-duration overvoltages can damage sensitive components, ensuring that surges are clamped before they can cause harm.

  • High Energy Absorption CapacityAble to absorb large amounts of energy from severe surge events, such as those caused by direct lightning strikes or major system faults. This high energy handling capability ensures that the arrester can effectively mitigate the impact of such events, protecting the AC filter components from damage.

  • Durable and Weather-Resistant ConstructionHoused in robust materials, such as composite silicone rubber or porcelain, which offer excellent resistance to environmental factors including UV radiation, extreme temperatures, moisture, and pollution. This durability ensures long-term reliable operation in both indoor and outdoor installations, reducing maintenance requirements.

  • Low Leakage CurrentExhibits minimal leakage current during normal operation, which helps to minimize power loss and prevent unnecessary heating. This is important for maintaining the efficiency of the AC filter system and ensuring that the arrester does not interfere with the normal operation of the filter.

  • Compliance with Industry StandardsManufactured in accordance with relevant international standards, such as IEC and IEEE standards, ensuring that they meet strict performance and safety criteria. Compliance with these standards guarantees that the arresters are compatible with AC filter systems worldwide and can be relied upon for effective protection.

  • Easy Integration with Filter SystemsDesigned with dimensions and mounting configurations that allow for easy integration into existing AC filter systems. This simplifies installation and ensures that the arrester can be seamlessly incorporated into the filter circuit without requiring major modifications to the system.

Model 

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Voltage Residual (Switching Impulse)

Voltage Residual (Nominal Impulse)

Current Residual Voltage

Current - Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times

 
       

(Peak Value

(Peak Value

(Peak Value

(Peak Value

 

Y10W1-132/353W

132

 

110

191/3

305

353

 

2400

4500

Y10W1-23/55W

23

 

18.4

32/5

49

55

 

5000

2370

Y10W1-23/55W

23

 

18.4

32/4

53

55

 

4000

2370

Y10W1-23/55W

23

 

18.4

32/1

45

55

 

600

1256

Y10W1-71/194W

71

 

56

102/4

157

194

 

2400

2500

Y10W1-125/340W

125

 

100

182/6

 

340

 

6000

5320

Y10W1-85/339W

85

 

68

124/2

 

339

 

5000

4335

Y10W1-70/338W

70

 

56

102/2

 

338

 

5000

4335

Y10W1-145/408W

145

 

120

210/4

327

408

 

2400

6000

 

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Medium and High Voltage Switchgear/Power and Distribution Transformers/Lightning Protection and Electrical Insulation/Substations and E-Houses/Electrical Panel and Controlgear
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Login
or continue with
New here?
Register