• Counter For Surge Arrester for recording the operation times
  • Counter For Surge Arrester for recording the operation times
Counter For Surge Arrester for recording the operation times
discuss personally
Model
JSY-11S
Basic info
Brand Wone
Model NO. Counter For Surge Arrester for recording the operation times
Nominal Discharge Current 10kA
Residual Voltage not Exceeds 2kA
Series Arrester Auxiliary Equipment
Product Detail

Description:

JSY-11S surge arester counter is a device for recording the operation times of a lightning arrester under the lightning arrester connecting in series. It is applicable to lightning arrester with grade not exceeding 220KV. The environmental condition of using site is the same to the connecting lightning arresters. It is not applicable to places with heavy pollution and strenuous vibration. It applies zinc oxide varistor and has relative improvement on the electrical performance.

Using conditions:

  • It is applicable to exterior or interior.

  • Environmental temperature (-40 to +40) C . 

  • The altitude can't be over 2000m.

  • Supply frequency (48 to 62) Hz.

  • No place with strenuous vibration.

Structure and characteristic:

Electric Principle:

  • A discharge counter mainly consists of components like sampling varistor, silicon bridge rectifier, high-voltage condenser and electromagnetic counter, etc. The discharge current of lightning arrester generates voltage on the varistor (nonlinear resistance), and charges on condenser through silicon bridge rectifier and discharge to electromagnetic counter. The counter records every time it discharges, so as to realize the operation times of lightning arrester.

  •  The enclosure of this product applies premium stainless steel enclosure. It has good rot resistance and good sealing property, not being influenced by external environment. Inner components have good ageing resistance, which can run in the electric power system for long term.

JSY-11S lightning arrester discharge counter applies dual pointer display. The display has the advantages like clear display and easy observation, etc. The counting cycle index is from 0 to 999, which is to say 1000 times for a cycle. It is beneficial to record the times of lightning of going through the lightning arrester relatively completely in a short time.

Main Technical Properties:

Product implementing standard: JB/T 10492-2011 Monitoring Device for Metal Oxide Lightning Arrester. The main technical properties are as the below table:

image.png

Inspection and acceptance & installation:

 Inspection and Acceptance:

  •  When inspect and accept products, open the packing case and inspect whether the accompanying documents (operation manual,packing list and certificate of approval) are complete.

  •  Inspect whether the accessories are complete according to the packing list. Meanwhile, inspect whether the product appearance has scrape and whether the insulator has crack and dropped piece.

When installing, the dig angle between the plane of the panel of counter and the horizontal plane should be smaller than 85° , so as to avoid waterlogging influencing observation. Use M10 bolts to fix the metal enclosure base to the metal support and connect the ground through the ground bus. (The monitor base can also be the ground bus.) Another end connects the electrode through the top of the insulator and connects the low-pressure end of the lightning arrester by wire (or aluminum strip). It must install securely and contact reliably.(Installation dimension please see the attached drawing.)

Test methods:

When users receive products, they can use the below methods to test the products.

  • Operation Performance Test: Connect a condenser with withstand voltage over 500V and capacity over 5MFD to a 500V megger. Rotate the megger with the rotate speed of 90 to 120 per minute to charge the condenser. When the voltage of the condenser is monitored to be 300V by universal meter, disconnect the condenser connecting with the megger. Use the condenser to discharge the counter instantaneously and the discharge counter should count it as once. Perform it for 10 times consecutively and they should be reliable operations.

  • The test of discharge counter can also be performed by the specialized tester produced by our factory. For details please see Instruction of JCQT6000 Lightning Arrester Monitor Tester.

Precautions:

  • After putting the discharge counter into operation, operators on duty shall keep monitoring it and record the reading of the discharge counter regularly, so as to master the times of lightning current going through the lightning arrest.

  • Note to not overstress on the insulator to avoid destroying the sealing. Meanwhile, users can not take apart the lightning arrester discharge counter casually.

Quality assurance:

On the condition of user using and installing the product according to regulations, the company is responsible for the “Three Guarantees” after-sales service within the period of “Three Guarantees” . The period of “Three Guarantees” is a year. If user has special requirements, he can come and mail for negotiation.

image.png

Schematic Diagram of Structure and Installation

How does a surge arrester counter work?

When a surge current (such as overcurrent caused by lightning) passes through the surge arrester, the arrester operates to divert the surge current into the ground. At the same time, the current sensor in the connected surge arrester counter detects this current signal. The signal generated by the sensor is then converted and processed by the signal processing circuit. After processing, the signal triggers the counting unit to increment the count, causing the displayed number to increase by one, indicating that the arrester has performed one operation.

Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!