• Standard APG Clamping Machine
Standard APG Clamping Machine
$38000.00
Model
HAPG-1210
HAPG-1000
HAPG-880
HAPG-860
Basic info
Brand Wone
Model NO. Standard APG Clamping Machine
Heating power 24Kw
weight 5.7T
Series HAPG-860
Product Detail

Description

This series belongs to Standared APG clamping machine, the min clamp plate size is 600X800mm, and the Max clamp plate size is: 1200X1000mm, can meet production requirement from 11-36KV, such as current transformer, voltage transformer, insulator, bushing, spout, SFG gas-insulated indoor switch disconnector. Etc.The upper and lower core distance can be customized, foundation pit is necessary if lower core travel distance above 500mm

Specifications

Model NO.

HAPG-860

HAPG-880

HAPG-1000

HAPG-1210

Clamp plate size(mm)

600*500

800*800

1000*1000

1200*1000

Clamp force

18T

18T

21T

21T

Min/Max clamp plate strokemm

240*1250

240*1250

240*1450

240*1450

Upper&Lower core puller strokemm

760*350

760*350

760*450

760*450

Heating power

12kW

16kW

24kW

24kW

Hydraulic station power

5.5kW

5.5kW

5.5kW

5.5kW

Horizontal tilting angle

0-5°

0-5°

0-5°

0-5°

mould load weight

2T

2T

3T

3T

Machine weight

4.5T

4.8T

5.3T

5.7T

Machine dimensionmm

3100*1300*2500

3100*1300*2500

3400*1150*2800

3400*1150*2800

machine work process

企业微信截图_17204031354027.png

企业微信截图_17204032743267.png



Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge