• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Slim type PLC

  • Slim type PLC
  • Slim type PLC
  • Slim type PLC
  • Slim type PLC
  • Slim type PLC

Key attributes

Brand RW Energy
Model NO. Slim type PLC
Rated voltage 24V
Product edition code ME (Sport Ethernet)
Series XL

Product descriptions from the supplier

Description

XL series PLC has card design, ultra-thin appearance,Equipped with powerful CPU processor, complete functions, high reliability and compact structureEspecially suitable for narrow installation space.

feature:

  1. Slim appearance, small and practical

  2. Strong compatibility

  3. Strong expansion ability

  4. utstanding cost performance

  5. Save more installation space

XL1 Economic type product series

configuration:1.  Program capacity256KB 2. I/O sequential control 3. Max I/O 16 points 4. Basic instruction 0.02-0.05us 5. RS232,RS485 6. X-NET fieldbus 7. USB port high speed download (max 12Mbps)

XL3 Standard type product series

configuration:1. Program capacity 256KB 2. I/O seq uential control 3. Max 1/0 352 points 4. Basic instruction 0.02~0.05us 5. RS232,RS485 6. X-NET field bus 7. USB port high speed download (max 12Mbps) 8.3 channels high speed counter (single phase up to 80KHz, AB phase up to 50KHz) 4. 2-4 channels 100KHz pulse output

XL5 Enhanced type product series

configuration:1. Program capacity512KB 2. I/O sequential control 3. Max I/O 576 points 4.Basic instruction 0.02-0.05us 5. RS232.RS485 5. X-NET fieldbus 6. USB port high speed download (max 12Mbps) 8. 3-4 channels high speed counter (single phase up to 80KHz, AB phase up to 50KHz) 9. 2-10 channels 100KHz pulse output

XL5E Ethernet communication type product series

configuration:1. Program capacity 1MB 2. I/O sequential control 3. Max I/0 576 points 4. Basic instruction 0.01-0.03us 5. RS232,RS485,RJ45 6. X-NET fieldbus 7. 2-10 channels 100KHz pulse output 8. 3-10 channels high speed counter (single phase up to 80KHz, AB phase up to 50KHz) 9. Online downloading 10. Bipolarinput

XL5N CAN communication type product series

configuration1. Program capacity 1MB 2. I/O sequential control 3. Max I/0 544 points 4. Basic instruction 0.01-0.03us 5.  RS232,RS485,Rj45 6. 2 channels CAN communication, support CANopen and CAN free fommat communication 7. Support Ethernet communication 8. 2 channels 100KHz pulse output 9. 3 channels high speed counter (single phase up to 80KHz, AB phase up to 50KHz)i0nline downloading

XLME Ethernet communication type product series

configuration:1. Program capacity 1MB 2.I/O sequential control 3. Max l/0 576 points 4. Basic instruction 0.01-0.03us 5. RS232,RS485, Rj45 6. X-NET fieldbus 7. 4-10 channels 100KHz pulse output 8. 4-10 channels high speed counter (single phase up to 80KHz, AB phase up to 50KHz) 9. Linear/arc interpolation 10. Follow-up function 11. Online downloading

XLH EtherCAT type product series

configuration:1. Program capacity2~4MB 2. Max I/O 542 points 3. Basic instruction 0.01-0.05us 4. RS232,RS485,RJ45 5. Ethernet communication 6. X-NET fieldbus 7. EtherCAT bus control 8. channels 100KHz pulse output 9. 4 channels high speed counter (up to 200KHz) 10. Follow-up function 11. 3 axes linear/acrinterpolation 12. 16 channels electronic cam (XLH-24A16L/XLH-30A32L not supported) 13. Bipolar input

XL5H EtherCAT type product series

configuration:1. Program capacity 1M 2. Max I/O 536 points 3. Basic instruction 0.01~0.05us 4. RS232,RS485,RJ45 5. Ethernet communication 6. X-NET fieldbus 7. EtherCAT bus control 8. 2 channels 100KHz pulse output 9.  3 channels high speed counter (single phase max 80K, AB phase max 50K) 10. Follow-up function 11. Online downloading 12. Bipolar input

 

 

 

 

Documentation Resource Library
Restricted
XL Series slim type PLC Data sheet
Operation manual
English
Consulting
Consulting
FAQ
Q: How many I/O points can the XL series expand up to?
A:

According to different models, enhanced models such as XL5/XLME/XLH can support up to 576 I/O points and meet diverse control requirements through modular expansion.

Q: Does the XLH model support EtherCAT master functionality?
A:

Yes, the XLH series is an EtherCAT model in the XL product line, supporting EtherCAT bus master control, 200kHz high-speed counting, 3-axis interpolation, and electronic cam, enabling high-performance distributed control.

Q: Where is the XL series ultra-thin PLC most suitable for installation?
A:

The XL series adopts a card style ultra-thin design, which is particularly suitable for control cabinets with limited space, such as small equipment, OEM machinery, elevator control, food packaging machines, and other volume sensitive but stable control scenarios.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.