• LZW-72.5 Outdoor Current Transformer
LZW-72.5 Outdoor Current Transformer
discuss personally
Model
LZW-72.5
Basic info
Brand Wone Store
Model NO. LZW-72.5 Outdoor Current Transformer
Rated voltage 66KV
Rated frequency 50/60Hz
Rated current ratio 500/5
Series LZW
Product Detail

Product Overview

LZW-72.5 current transformer, epoxy resin casting insulation and outdoor installation, is widely used for measuring current, electric energy and protective relaying in the power system with the rated frequency 50Hz or 60 Hz and rated voltage 66kV or 69kV.

Key Features

  • High-Voltage Grade Outdoor-Specific Design:The LZW-72.5 features a 72.5kV rated voltage design with insulation levels reaching 125kV (lightning impulse) / 70kV (power frequency withstand voltage). It strictly complies with GB/T 4703.2 and IEC 60044-2 standards, optimized for high-voltage outdoor scenarios such as 110kV and below outdoor substations and overhead lines. This ensures safe and stable operation in long-term high-voltage environments, effectively reducing the risk of insulation breakdown.

  •  Extreme Climate Protection Structure:The product incorporates a triple protection system: it uses silicone rubber composite insulation materials and aluminum alloy flanges, achieving 10,000 hours of UV aging resistance; reaches IP68+ protection, enabling long-term operation at 2 meters underwater, with special designs to withstand 30mm/h snow accumulation and ice loads up to 20mm thickness; passes 3,000 hours of salt spray testing, with a creepage distance of 31mm/kV, fully meeting the requirements of harsh outdoor environments such as plateaus, extreme cold, and coastal areas.

  • Dual-Winding High-Precision Measurement System:The LZW-72.5 integrates a 0.2S-class metering winding and a 5P30-class protection winding. The metering winding maintains a ratio error ≤±0.2% within 1%~120% rated current, meeting high-precision energy metering needs; the protection winding has a composite error ≤5% at 30 times rated current with 8ms fast response, effectively ensuring the speed of relay protection devices. It includes 3 sets of ratio taps (e.g., 600/5A, 800/5A, 1000/5A), which can be flexibly adjusted via an outdoor-specific sealed switch without disassembly to adapt to different load current scenarios.

  • Intelligent Condition Monitoring and Communication Technology:The product is equipped with multi-parameter sensors for temperature (-40℃~+120℃), humidity, and insulation dielectric loss, collecting real-time operational data. It supports IEC 61850-9-2 digital protocol and DL/T 645 standard, while retaining a 4~20mA analog output interface, enabling seamless integration into smart substation systems or compatibility with old monitoring equipment. In-depth analysis of historical data through cloud platforms predicts insulation aging trends in advance, providing data support for operation and maintenance decisions and significantly reducing outdoor inspection frequency and costs.

Main technical parameter

  • Rated voltage : 66kV or 69kV

  • Highest voltage for equipment : 72.5 kV

  • Rated insulation level : 72.5/140/325kV

  • Rated secondary current :5Aor1A

  • Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers or ANSI IEEE STD C57.13-2008

Other technical parameter pls see as follow:

Double ratios

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline drawing

 

 

 

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×