• LMZB-24 Outdoor Current Transformer
LMZB-24 Outdoor Current Transformer
discuss personally
Model
LMZB-24
Basic info
Brand Wone Store
Model NO. LMZB-24 Outdoor Current Transformer
Rated voltage 22kV
Rated frequency 50/60Hz
Rated current ratio 500/5
Series LMZB
Product Detail

Product Overview

LMZB-24 epoxy resin casting busbar type current transformer, is widely used outdoor for measuring current, electric energy and protective relaying in the electrical system with rated frequency 50Hz or 60Hz and highest voltage for equipment 24kV.  Rated primary current is 400-10000Aand rated secondary current is 5A or 1A.

Key Features

  • 24kV-Class Outdoor High-Voltage Adaptation Design:The LMZB1-24 outdoor current transformer features a 24kV rated voltage design with insulation levels reaching 75kV (lightning impulse) / 40kV (power frequency withstand voltage). It strictly complies with GB/T 4703.2 and IEC 60044-2 standards, and is optimized specifically for scenarios such as 20kV and below outdoor substations, ring main units, and cable distribution boxes. Its structural design fully accounts for the long-term operational requirements of high-voltage outdoor environments, effectively resisting voltage fluctuations and insulation aging, reducing the risk of equipment failures caused by insulation breakdown, and ensuring the stable operation of the power system.
  •  All-Climate Protection Structure:This product adopts a dual protective barrier composed of silicone rubber composite insulation material and a corrosion-resistant aluminum alloy shell: it has passed 7000 hours of UV aging testing, enabling it to withstand long-term outdoor exposure; it reaches IP68 protection level, allowing continuous operation at 1 meter underwater. Meanwhile, through a specially designed structure, it can resist snowfall of 20mm/h and ice loads of 10mm thickness. Verified by 2000 hours of salt spray testing, it has a creepage distance of 20mm/kV, making it suitable for various harsh outdoor environments such as coastal areas, high-altitude regions, and cold areas, and reducing the impact of climatic factors on equipment performance.
  • Dual-Winding High-Precision Measurement System:It integrates a 0.2S-class metering winding and a 5P20-class protection winding. The metering winding maintains a ratio error of ≤±0.2% within the range of 1%~120% rated current, meeting the requirements of high-precision electric energy metering and line loss analysis; the protection winding has a composite error of ≤5% under 20 times the rated current, with a response time of ≤10ms, which can quickly trigger relay protection devices to ensure safe disconnection in case of power grid faults. It is equipped with 2 sets of ratio taps (such as 300/5A, 600/5A), which can be adjusted through an outdoor sealed changeover switch, adapting to different load currents without disassembly, thus improving the flexibility of on-site application.
  • Enhanced Safety and Environmental Adaptability:It is built with a pressure balance valve to avoid shell condensation and air pressure deformation caused by temperature differences, and can be optionally equipped with explosion-proof certification (Ex d IIB T4), making it suitable for outdoor areas with flammable and explosive risks. Its anti-electromagnetic interference performance complies with IEC 61000-4-5 standards, and it can resist 60kA lightning strikes (10/350μs waveform). It maintains stable measurement accuracy even in strong electromagnetic environments, providing reliable current monitoring and protection guarantees for 20kV-class outdoor power grids.

Main technical parameter

  • Rated voltage: 20 kV or 22kV etc
  • Rated secondary current:5Aor1A
  • Rated insulation level: 24/50/125 kV
  • Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers or IEC61869-1&2-2012 etc.

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline

Know your supplier
Wone Store
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/MV & LV CT PT/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!