Brand | Switchgear parts |
Model NO. | GRV8-4UVR Three Phase Under Voltage Relay |
Rated frequency | 45Hz-65Hz |
Series | GRV8 |
The GRV8-4UVR is a specialized three phase under voltage relay. It‘s compact 36mm width allows for seamless installation in space-constrained control panels, while the adjustable settings provide flexibility to tailor protection to your specific needs. Whether you’re managing a manufacturing plant, HVAC system, or power distribution network, the GRV8-4UVR delivers the precision and reliability you need.
Supply Voltage:AC 220V / 380V / 400V
Measuring Frequency Range:45Hz – 65Hz
Voltage Measurement Accuracy:<1%
Under Voltage Setting Range:Adjustable (e.g., 170V – 210V per phase)*
Trip Delay Time:Adjustable (e.g., 0.1s – 10s)*
3-Phase Voltage Monitoring: Unlike single-phase relays, the GRV8-4UVR monitors all three phases simultaneously, ensuring balanced protection for systems where phase integrity is critical.
Adjustable Under Voltage Thresholds: Fine-tune the under voltage protection levels to match the specific requirements of your equipment.
Phase Imbalance and Sequence Protection: Detects and responds to phase imbalances and incorrect phase sequences, preventing motor damage and system failures.
True RMS Measurement: Ensures accurate voltage detection, even in environments with harmonics or non-linear loads.
LED Indicators: Provides clear, real-time status updates for easy monitoring and diagnostics.
Compact Design: The 36mm width and DIN rail mounting make it ideal for space-efficient installations in control panels
Model | GRV8-4UVR Three Phase Under Voltage Relay |
Operating temperature | -20℃ to +55℃(-4℉ to 131℉) |
Storage temperature | -35℃ to +75℃(-22℉ to 158℉) |
Trip delay time(Tu) | 0.1s |
Tightening torque | 0.8Nm |
Electrical life(AC1) | 1*105 |
Mechanical life | 1*107 |
Konb setting accuracy | 10% of scale value |
Current rating | 10A/AC1 |
Output | 1×SPDT |
Rated supply voltage(Un) | 220V/230V/240V |
Switching voltage | 250VAC/24VDC |
Rated supply frequency | 45Hz-65Hz |
Hysteresis | 5V |
Weight | 63g,65g |
Dimensions | 90×18×64mm |
Power on delay time(Td) | Adjustable: 5min-15min |
Recovery delay time(Tr) | Adjustable: 5min-15min |
Mounting/DIN rail | Din rail EN/IEC 60715 |
Standards | EN 60255-1,IEC60947-5-1 |
Overvoltage category | III |
Protection degree | IP40 for front panel/IP20 terminals |
Monitoring terminials | L1-L2-L3-N |
Supply terminals | L1-N |
Under voltage threshold | R:fixed 75% of Un |
Function | Under voltage |
Operating position | any |
Supply indication | green LED |
Output indication | red LED |
Measurement error | ≤1% |
Pollution degree | 2 |
Max.cable size(mm²) | solid wire max.1*2.5 or 2*1.5/with sleeve max.1*2.5(AWG 12) |