GRLE8-01 Earth Leakage Relay AC 30ma-30A

  • GRLE8-01 Earth Leakage Relay AC 30ma-30A
  • GRLE8-01 Earth Leakage Relay AC 30ma-30A

Key attributes

Brand Switchgear parts
Model NO. GRLE8-01 Earth Leakage Relay AC 30ma-30A
Rated frequency 50/60Hz
Series GRLE8

Product descriptions from the supplier

Description

GRLE8-01 Earth Leakage Relay Product Highlight:

Comprehensive Residual Current Detection

Type A Compliance: Reliably detects sinusoidal AC and pulsating DC residual currents, suitable for modern inverters and rectifier equipment.

Wide Current Range: Covers leakage currents from 30mA to 30A with high accuracy (±5%), ensuring precise protection.

Customizable Protection Settings

10 Adjustable Trip Levels: Offers settings at 30mA, 100mA, 300mA, 500mA, 1A, 3A, 5A, 10A, 20A, and 30A to meet diverse application needs, including main protection, branch protection, or fire monitoring.

9 Adjustable Delay Times: Selectable at 0s, 0.15s, 0.25s, 0.5s, 1s, 2s, 3s, 5s, 7.5s, and 9s, enabling precise coordination with upstream protection to prevent false tripping and ensure power continuity.

30mA Mandatory Zero Delay: When set to the most sensitive 30mA (personal safety protection level), the relay trips instantly without delay, rapidly cutting off power to safeguard lives.

Advanced Monitoring and Indication

Four-Stage LED Warning System: LEDs illuminate steadily when leakage current reaches 25%, 50%, or 75% of the set value, clearly indicating leakage trends; the fourth LED signals trip status.

ZCT Detection: When the residual current transformer (ZCT) encounters an error, LEDs ①②③④ flash continuously.

Robust and Durable Design

Wide Voltage Range: Operates reliably under grid voltage fluctuations of AC 85-265V (50/60Hz).

Flexible Reset Modes: Supports manual and automatic reset (via Y1-C connection) to meet diverse operational needs.

DIN Rail Installation: Compact size (90mm × 36mm × 64mm) for easy installation.

High Durability: Mechanical lifespan of 1×10^7 cycles and electrical lifespan (AC1) of 1×10^5 cycles, ensuring long-term reliable performance.

The GRLE8-01 Earth Leakage Relay combines precision, flexibility, and durability, featuring a wide current range, customizable settings, and an advanced LED indication system to ensure safety and reliability for your electrical systems. This versatile relay is designed for both single-phase and three-phase power systems, making it ideal for applications such as elevators, variable-frequency air conditioners, electric vehicle charging stations, and industrial control systems.

Voltage range:AC85-265V 50/60Hz

Operation range:30,100,300,500mA and 1,3,5,10,20,30A

Trip level limits:85% of setvalue

Trip time delay:0,0.15,0.25,0.5,1,2,3,5,7.5,9sec NA when leakage level set 30mA

Model GRLE8-01 Earth Leakage Relay
Function Earth leakage Relay
Supply terminals A1-A2
Voltage range AC85-265V 50/60Hz
Burden 3VA
Operation range 30,100,300,500mA and 1,3,5,10,20,30A
Trip level limits 85% of setvalue
Trip time delay 0,0.15,0.25,0.5,1,2,3,5,7.5,9sec
NA when leakage level set 30mA
Reset time ~2sec
Response time ≤30ms(if trip current≥5×I△n)
≤50ms(if trip current=1×I△n)
Reset value 85% of trip level
ZCT detection absent or short
Accuracy Trip:±5% of set trip current
Time:±5% of set time±50ms
Reset mode Manual/Auto reset
Output 1 SPDT
Current rating 10A/AC1
Switching voltage 250VAC/24VDC
Min.breaking capacity DC 500mW
Mechanical life 1×10^7
Electrical life(AC1) 1×10^5
Operating temperature -20℃~+55℃
Storage temperature -35℃~+75℃
Humidity Up to 95% RH(non-condensing)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP20
Operating position any
Overvoltage cathegory III.
Pollution degree 2
Max.cable size(mm²) 1×2.5mm² or 2×1.5mm²  0.4N·m
Dimensions 90mm×36mm×64mm
Standards IEC 60947-2
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.