Digital Timer Switch THC 822 16A Weekly Programmable

  • Digital Timer Switch THC 822 16A Weekly Programmable
  • Digital Timer Switch THC 822 16A Weekly Programmable

Key attributes

Brand Switchgear parts
Model NO. Digital Timer Switch THC 822 16A Weekly Programmable
Rated voltage AC220V
Rated normal current 16A
Rated frequency 50/60Hz
Series THC-822

Product descriptions from the supplier

Description

The THC822 series periodic timer can be directly wired, with characteristics such as small size, low power consumption, wide operating temperature range, and strong anti-interference ability. At the same time, the THC822 series periodic timer also has multiple functions such as daylight saving time, sleep mode, automatic time adjustment, and countdown.

THC822 Periodic Timer Product Features:
1. The TOP control contacts are 2 channels and 2 groups (2C).
2. 44 programs can be set within 24 hours or a week, with a small set time interval of 1 minute.
3. 44 pulse programs can be set within 24 hours or a week, with a small set time interval of 1 second.                                  
4. 18 loop programs can be set within 24 hours or a week.
5. Has strong anti-interference function.
6. Built in battery, it will continue to operate and display after power failure.
7. The language system of six countries includes English, French, German, Italian, Portuguese, and Spanish.
8. LCD display screen, directly displaying year/month/day/week/time.
9. 35mm standard rail installation.

Features

Item No

THC822

Dimensions(mm)

86x36x66

Full Timing Range

24h/7days random switching, holiday program, pulse, and cycle program

Rated Voltage

AC220V 50/60HZ 85%~110%

Contact Capacity

16(10)A、250VAC

Contact Form

2 changeover switch

Accuracy

≤1s/d (25℃)

Display
Munting Form

LCD
DIN RAIL

life

Electrical

≥105 times

Mechanical

≥107 times

Ambient Temperature
Min. switching time

 -10℃~+50℃
1 min

Programmable

44ON/44OFF

Storage Battery

3 YEARS

Consumed power

7.5VA

QTY

100PCs

G.W

18kg

N.W

17kg

MEAS

390x220x375mm

FAQ for
Q: What are the core features and advantages?
A:

The core functions and advantages focus on four dimensions: flexible programming, precise control, stable reliability, and multi-scenario adaptation:

· High-degree-of-freedom programming: Supports 44 groups of "on/off" programs (including 44 pulse programs) with a timing range of 1 minute ~ 168 hours (full-week cycle), and can set holiday mode and random switching to meet complex time-period control needs.

· Seasonal time adaptation: Built-in automatic daylight saving/winter time switching function, no manual adjustment required, adapting to seasonal time changes in different regions around the world.

· High-reliability design: Equipped with a built-in lithium battery for power failure memory (battery life ≥3 years), and automatically executes preset programs after power recovery; industrial-grade anti-interference capability, with an operating temperature range of -10℃~+50℃, adapting to harsh electrical environments.

·2-channel and multi-language: 2 groups of changeover contacts (2 changeover switches) to control two loads simultaneously; supports 6 languages including English, German, Italian, Portuguese, adapting to usage habits in multiple overseas regions.

·Convenient installation and operation: 35mm DIN rail plug-and-play, clear and intuitive LCD display, simple key operation, and programming can be completed without professional technology.

Q: What is the THC 822 Weekly Programmable Digital Timer Switch?
A:

The THC 822 is a 2-channel weekly programmable digital timer switch specially designed for automatic control scenarios, compatible with AC 220V-240V voltage and 50/60Hz frequency, with rated currents covering 16A/20A/25A/30A (resistive load). Its core function is to control circuit on/off according to weekly cyclic preset programs. The device supports 44 groups of "on/off" program settings (including pulse and cycle programs), with functions such as automatic daylight saving/winter time switching, power failure memory (built-in lithium battery life ≥3 years), random switching and holiday programs. Adopting 35mm standard DIN rail installation, it has a compact size (86×36×66mm) and an accuracy of ≤1 second/day (25℃). Widely used in commercial lighting, agricultural aquaculture equipment, industrial ventilation systems and other scenarios to achieve unattended automatic control.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application