• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Digital Timer Switch THC 15A-2C Astronomical Timer

  • Digital Timer Switch THC 15A-2C Astronomical Timer
  • Digital Timer Switch THC 15A-2C Astronomical Timer
  • Digital Timer Switch THC 15A-2C Astronomical Timer
  • Digital Timer Switch THC 15A-2C Astronomical Timer
  • Digital Timer Switch THC 15A-2C Astronomical Timer

Key attributes

Brand Switchgear parts
Model NO. Digital Timer Switch THC 15A-2C Astronomical Timer
Rated voltage AC220V
Rated normal current 20A
Rated frequency 50/60Hz
Series THC-15A-2C

Product descriptions from the supplier

Description

The THC-15A/20A/30A series timer is equipped with 16 sets of time settings, which have functions such as error correction, power-off memory, and precision sensitivity. It can ensure stable product operation, precise timing control, and achieve intelligent cycling effect. Meanwhile, the THC-15A/20A/30A series editable timer is commonly used in places such as street lamps, light boxes, neon lights, production equipment, agricultural breeding, warehouse ventilation and dehumidification, automatic preheating, broadcasting and television equipment, etc. It has a wide range of applications and strong practicality, making it a cost-effective timer.

THC15A/20A/30A series editable timer product features:
1. With precision and sensitivity, the product can operate stably.                                                                        
2. Equipped with power-off memory function.
3. It has error correction function.
4. There are 16 sets of adjustable times.
5. The product has a built-in battery that can run continuously after a power outage.
6. Installation of 35mm standard card rail.

Features

ItemNo

THC15A-2C 16A, 20A,25A,30A, THC15B-2C 16A, 20A,25A,30A

Voltage range

AC 220-240V 50Hz/60Hz(Other special voltages can be customized)

Timing error

AC 180-250V

Switching frequency

≤1s/d (25℃)

Power consumption

8ON+8OFF

Display

4VA (max)

Electrical life

LCD

Mechanical life

10⁵times (Rated load)

Min. switching time

1min

Contact

2NO+2NC/ 2NC

Control current

16A,20A,25A,30A

Mounting

DIN rail mounting

Contact Capacity

THC15A-2C 16A Resistive: 16A/250V AC(cosφ=1)  THC15B-2C 16A Resistive: 16A/250V AC(cosφ=1)
THC15A-2C 20A Resistive: 20A/250V AC(cosφ=1)     THC15B-2C 16A Resistive: 16A/250V AC(cosφ=1)
THC15A-2C 25A Resistive: 25A/250V AC(cosφ=1)     THC15B-2C 16A Resistive: 16A/250V AC(cosφ=1)
THC15A-2A 30A Resistive: 30A/250V AC(cosφ=1)     THC15B-2C 16A Resistive: 16A/250V AC(cosφ=1)

QTY

100PCS

G.W

19KG

N.W

18.5KG

MEAS

460x320x290mm

Temperature

-10~40℃

Relative humidity

35~85%RH

Documentation Resource Library
Restricted
Digital Timer Switch THC 15A-2C Astronomical Timer Catalogue
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the core functions and advantages of the THC 15A-2C?
A:

The core functions and advantages focus on three dimensions: astronomical adaptation, dual-channel control, high reliability:

· Precise astronomical timing: Automatically matches sunrise and sunset times after entering latitude and longitude, intelligently adjusts with seasonal sunlight changes, no manual modification required;

· Dual-channel synchronous/independent control: 2 groups of contacts support synchronous (control the same load) or independent (control two loads) operation, adapting to multi-device scenarios;

Highly flexible programming: 80 custom programs can be superimposed with astronomical mode (e.g., "turn on lights 10 minutes before sunset"), minimum switching time 1 minute;

· Stable and durable: Built-in lithium battery ensures power failure memory; industrial-grade chip resists electromagnetic interference; operating temperature -10~40℃, adapting to complex environments.

Q: What is the THC 15A-2C Astronomical Timer Switch?
A:

The THC 15A-2C is a latitude-longitude driven dual-channel astronomical timer switch, compatible with AC 220-240V/50-60Hz voltage, with rated currents covering 16A/20A/25A/30A (resistive load). Its core function is to automatically calculate daily sunrise and sunset times by inputting the latitude and longitude of the installation location, realizing automatic circuit on/off with natural light. It also supports 80 groups of custom on/off programs, power failure memory (built-in lithium battery life ≥3 years), industrial-grade anti-interference, and DIN rail mounting. Its size fits distribution cabinets, widely used in municipal street lights, landscape lighting, agricultural aquaculture, etc.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.