• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


695 W - 730 W High Effficiency Bifacial N-type Heterojunction(HJT) Technology

  • 695 W - 730 W High Effficiency Bifacial N-type Heterojunction(HJT) Technology

Key attributes

Brand Wone
Model NO. 695 W - 730 W High Effficiency Bifacial N-type Heterojunction(HJT) Technology
Power Bifaciality 85%
Max. System Voltage 1500V (IEC)
Max. Series Fuse Rating 35 A
Module Fire Performance CLASS C
Max. power of the module 695W
Max. efficiency of Module 22.4%
Series Bifacial N-type HJT Technology

Product descriptions from the supplier

Description

Features

  • Module power up to 730 W Module efficiency up to 23.5 %.

  • Up to 90% Power Bifaciality, more power from the back side.

  • No B-O LID, excellent anti-LeTID & anti-PID performance. Low power degradation, high energy yield.

  • Leading temperature coefficient (Pmax): -0.24%/°C, increases energy yield in hot climate.

  • Better shading tolerance.

Standard

  • Tested up to ice ball of 35 mm diameter according to IEC 61215 standard.

  • Minimizes micro-crack impacts.

  • Heavy snow load up to 5400 Pa, enhanced wind load up to 2400 Pa*.

Engineering drawing(mm)

image.png

CS7-66HB-710/ I-V gurves

image.png

Electrical date/STC*

企业微信截图_1730252297357.png

Electrical date/NMOT*


image.png

Electrical date

image.png

Mechanical charactheristics

image.png

Temperature characteristics

image.png

What is a bifacial N-type heterojunction cell module?

N-type Heterojunction Battery Technology:

The N-type Heterojunction Battery (abbreviated as N-HJ or HJT) is a special battery technology. It forms a heterojunction structure by depositing a layer of amorphous silicon film on an N-type silicon wafer. This structure endows the battery with the following advantages:

  • High Conversion Efficiency: The N-type Heterojunction Battery has a relatively high photoelectric conversion efficiency. Laboratory records show that it can reach over 26%.

  • Low Temperature Coefficient: This type of battery is less sensitive to temperature and can maintain a relatively high power generation efficiency even in a high-temperature environment.

  • Good Response to Low Light: The N-type Heterojunction Battery still performs excellently under low-light conditions and is suitable for use under various lighting conditions.

  • Low Power Attenuation: Due to the design of the battery structure, the N-type Heterojunction Battery has a low power attenuation rate, ensuring its long-term and stable working performance.

  • Long Lifespan: The N-type Heterojunction Battery has a relatively long working lifespan, reducing the risk of power attenuation.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.