Brand ROCKWILL
Model NO. 36kV 40.5kV 44kV 45kV Pure air insulated Ring Main Unit (RMU) / switchboard panel
Rated voltage 40.5kV
Rated normal current 630/800A
Rated frequency 50/60Hz
Series SM66

Product descriptions from the supplier

Description

Description :

Pioneer in China's eco-friendly switchgear sector, we have specialized in R&D and manufacturing of SF₆-free switchgear for decades. With core technologies, we have established industry standards. Boasting a fully independent end-to-end production chain, we have built a product matrix of zero-emission and high-reliability eco-friendly switchgear, making us a trusted choice for power grid construction.

SM66 unit type SF6 ring net cabinet with SF6 load switch as main switch, for whole cabinet is suitable for electric distribution automation and compact also expandable metal close switchgear. It characters in its simple structure, flexible operation, reliable interlocking and convenient installation etc.which can provide the satisfactory technical projects both for different application occasions and users. With the adoption of sensor technology and the protection relay up to date, plus the advanced technology and flexible assembly project, SM66 unit type SF6 ring net cabinet can completely meet the requirement of continuously variable market.

Main function :

  • Good Insulation Performance;

  • Strong Arc Extinguishing Ability;

  • Excellent safety performance ;

  • Flexible and Reliable Operation;

  • Compact Structure and Modular Design;

  • High Degree of Intelligence.

Technology parameters:

The voltage classes of some of these eco-friendly switchgears include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. and customization is available.

No

Item

Unit

Parameter

1

Rated voltage

kV

36

40.5

2

Rated frequency

Hz

50/60

3

Rated current

A

630/800

4

1min Power frequency withstand voltage

wet

kV

70

95

dry

kV

80

110

5

Lightning impulse withstand voltage

kV

170

185

6

Rated short circuit breaking current (peak)

kA

195

215

7

Rated active load and close circuit breaking current

A

400/630

8

Rated transferring current

A

1200

1000

9

Rated short circuit making current (peak)

kA

63

63

10

Rated cable offload

A

50

11

Transformer offload

A

16

12

Rated withstand current (peak)

kA

63

13

Short time withstand current (2s)

kA

25

14

Mechanism life

times

2000

2000

Outline dimension drawing:

36kV 40.5kV air insulated Ring Main Unit RMU (1).png

Fixing of units:

36kV 40.5kV air insulated Ring Main Unit RMU (2).png

36kV 40.5kV air insulated Ring Main Unit RMU (3).png

What is the purpose of a ring main unit RMU?

A:Ring main unit (RMU) is used to distribute electrical power in a medium - voltage distribution network. It allows for sectionalizing the network, isolating faults, and enabling power transfer between different sections of the ring - shaped power network, ensuring reliable power supply.

What does the RMU stand for?

A:RMU stands for Ring Main Unit. It is a type of electrical switchgear used in medium-voltage electrical distribution systems, typically for distributing power in a ring circuit configuration.

 

 

 

FAQ
Q: Is the installation process of environmentally friendly cabinets more complex than traditional cabinets?
A:
No, the installation process is basically the same as that of traditional cabinets and even simpler in some aspects. They do not require special SF6 gas filling and recycling equipment; only basic steps such as cabinet fixing, cable connection, and insulation gas filling (for gas-insulated types) are needed. Manufacturers usually provide detailed installation manuals and on-site guidance. Professional electricians can complete the installation after simple training.
Q: What are the requirements for the installation environment of environmentally friendly cabinets?
A:
The installation environment should be free of severe vibration, corrosive gases (e.g., sulfur dioxide, hydrogen sulfide), and flammable/explosive substances. The ambient temperature should be between -40℃ and +70℃, and relative humidity should not exceed 95% (without condensation). The installation site should have sufficient space for maintenance and ventilation, and the foundation should be flat and firm to ensure the cabinet's stability.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

Related Solutions

Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
-->
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.