• 35kV Low Loss Prefabricated Compact Substation for Grid
35kV Low Loss Prefabricated Compact Substation for Grid
discuss personally
Model
YBW-35
Basic info
Brand POWERTECH
Model NO. 35kV Low Loss Prefabricated Compact Substation for Grid
Rated voltage 35kV
Series YBW-35/0.4-2000
Product Detail

Description

An AC metal-enclosed shift switch cabinet is a three-phase, 50Hz indoor metal-enclosed switching device designed for power plants and substation systems. It operates at a rated voltage of 35kV, with a maximum current capacity of 2000A and a voltage limit not exceeding 40.5kV. Suitable for single-bus or single-bus segmented configurations, it serves as a reliable distribution solution.

This switchgear complies with standards such as DL/T 404-91, IEC 298, and GB 3906, incorporating essential safety features to prevent operational errors. These include protections against incorrect circuit breaker operation, live insertion or withdrawal of trolleys, grounding line faults, live grounding, and accidental energization of isolated sections (commonly referred to as the "five protections").

Compact substations are ideal for diverse applications, including residential communities, urban public distribution networks, busy downtown areas, and temporary construction power supply. Their versatility allows selection based on specific load requirements and environmental conditions. Since their introduction, compact substations have seen rapid adoption, with widespread use in developed countries—where they account for a significant share of distribution systems. In China, modernization and urban grid upgrades are driving their increasing deployment.

These substations are commonly employed in high-rise buildings, luxury residences, parks, residential complexes, small to medium industrial plants, mining operations, oil fields, and temporary construction sites, providing efficient power distribution within electrical networks.

 Features

  • Complete Power Distribution System – Integrates transformation, distribution, transmission, measurement, compensation, control, protection and communication functions in one unit.
  • Standardized Components – Consists of high-voltage switchgear, distribution transformer, low-voltage distribution panel and protective enclosure.
  • Outdoor Application Design – Features anti-corrosion, waterproof and dustproof construction suitable for long-term outdoor operation.
  • Compact Structure – Three-section integrated design (high-voltage, transformer, low-voltage) with small footprint.
  • Installation Advantages – Offers flexible siting, reduced civil works, shorter construction period and lower overall cost compared to conventional substations.
  • Reliable Operation – High operational stability with comprehensive protection functions.
  • Aesthetic Appearance – Modern enclosed design with better visual appeal than traditional solutions.
  • Wide Application Range – Ideal for urban grid upgrades, residential communities, industrial parks, commercial centers, transportation facilities and temporary power supply needs.
  • Technical Compliance – Meets relevant industry standards for performance and safety requirements.
  • Maintenance Friendly – Modular design simplifies inspection and servicing procedures.

Parameter

Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!