• 75 kVA ~ 2500 kVA UL-Listed Explosion-Proof Standard Pad-Mounted Transformer
75 kVA ~ 2500 kVA UL-Listed Explosion-Proof Standard Pad-Mounted Transformer
discuss personally
Model
ZGS-2500-33/0.4
ZGS-1000-33/0.4
ZGS-160-33/0.4
ZGS-2500-11/0.4
ZGS-1000-11/0.4
ZGS-160-11/0.4
Basic info
Brand Vziman
Model NO. 75 kVA ~ 2500 kVA UL-Listed Explosion-Proof Standard Pad-Mounted Transformer
Rated frequency 50/60Hz
Rated capacity 2500kVA
Primary voltage 33kV
Secondary voltage 0.4kV
Series ZGS
Product Detail

Description:

The UL-Listed Explosion-Proof Standard Pad-Mounted Transformer is an explosion-proof oil-immersed pad-mounted transformer certified by Underwriters Laboratories (UL), designed specifically for hazardous environments. Its core certifications and standards include:

  • UL Certification: Complies with UL 506 (Transformer Standard) and UL 1203 (Explosion-Proof Equipment Standard), ensuring safe operation in dangerous environments.
  • Explosion-Proof Rating: Typically marked as Class I, Division 1 (for flammable gas environments) or Class II, Division 1 (for combustible dust environments), adhering to the National Electrical Code (NEC 500/505).
  • Structural Standards: Based on IEEE C57.12.20 (American Pad-Mounted Transformer Standard) and NEMA 3R/4X (Enclosure Rating Standards).

Core Design Features:

  • Explosion-Proof Enclosure: Constructed with cast aluminum or stainless steel, joint surfaces and gaps strictly comply with UL 1203 (e.g., gap ≤0.15mm) to prevent flame propagation during internal arcing.
  • Pressure Relief System: Equipped with dual redundant pressure relief valves (operating pressure 55±5kPa) and spark arrestors to prevent tank rupture and secondary explosions.
  • Oil-Immersed Insulation: Utilizes high-flash-point insulating oil (e.g., silicone oil with flash point >300°C) or β-fluid (complying with UL 3406) to reduce fire risks.
  • Sealing Rating: Features fully welded construction with corrugated tanks, passing UL 50E explosion tests (methane-air mixture explosion test) to prevent ingress of combustible substances.
  • Electrical Connections: Equipped with explosion-proof cable glands (UL 1203 certified) and Ex d-type flameproof joints to ensure sparks at terminals do not ignite ambient gases.

Functions and Core Applications:

  • Safe Power Supply: Enables electrical energy conversion in flammable environments while preventing sparks or high temperatures from triggering explosions.
  • Fault Isolation: Contains internal faults (e.g., arcing, oil decomposition) within the enclosure through explosion-proof design.
  • Environmental Adaptation: With IP66 protection rating, resists ingress of corrosive gases and dust.

Parameter:

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!