• UL Listed Three Phase Pad Mounted Power Transformer
UL Listed Three Phase Pad Mounted Power Transformer
discuss personally
Model
ZGS-2500-33
ZGS-2500-11
ZGS-1000-33
ZGS-1000-11
ZGS-200-33
ZGS-200-11
Basic info
Brand Vziman
Model NO. UL Listed Three Phase Pad Mounted Power Transformer
Rated frequency 50/60Hz
Rated capacity 2500kVA
Primary voltage 33kV
Series ZGS
Product Detail

Description:

The UL-listed three-phase pad-mounted power transformer is an outdoor power distribution device compliant with the safety standards of Underwriters Laboratories (UL). It adopts a fully sealed pad-mounted structure, specially designed for medium and low-voltage power distribution systems. Its core characteristics are as follows:

Structural Standards:

  • Complies with UL 1562 (oil-immersed transformers) or UL 1836 (dry-type transformers) certifications, with a protection rating typically reaching IP65/66. It can be directly installed on concrete foundations and adapts to harsh outdoor environments (such as rain, dust, and high temperatures).

Electrical Parameters:

  • Capacity Range: Usually 50kVA to 5000kVA, meeting the load requirements of different scales.
  • Voltage Classes: The high-voltage side commonly includes 7.2kV, 12.47kV, 13.8kV, 34.5kV, etc.; the low-voltage side outputs three-phase four-wire voltages such as 208V/120V, 480V/277V, 600V (compatible with North American standards).

Insulation and Cooling:

  • Oil-Immersed Type: Uses mineral oil or environmentally friendly high-flash-point oil (such as silicone oil) as the insulation medium, combining cooling and fireproof performance (complying with UL 1203 explosion-proof standards).
  • Dry-Type (Optional): High-voltage windings are cast with epoxy resin, requiring no maintenance, suitable for scenarios with higher fireproof requirements.

Core Functions:

Power Conversion and Distribution:

  • Steps down medium-voltage power grids (e.g., 13.8kV) to low voltage (e.g., 480V), providing stable power for three-phase loads (such as motors and large equipment), while supporting multi-loop 分户配电 (household distribution).

Safety and Reliability Assurance:

  • The fully sealed structure isolates external pollution, preventing moisture and dust from affecting insulation performance.
  • Equipped with a temperature controller, pressure relief valve, and gas relay (for oil-immersed types), it automatically protects against short circuits or fire risks when oil temperature is too high (e.g., exceeding 95°C) or internal faults occur.
  • UL certification ensures products comply with North American safety codes (such as short-circuit withstand capacity and insulation voltage standards).

Grid Compatibility:

  • Supports harmonic suppression design (optional filter windings), reducing interference from non-linear loads (such as frequency converters and data center equipment) to the power grid and improving power quality.

Typical Application Scenarios:

Commercial and Industrial Sectors:

  • Data Centers/Bitcoin Mining Farms: Supplies three-phase 480V power for server clusters and mining machines, supporting high-load continuous operation. Redundant windings are often configured to ensure 99.99% power availability.
  • Manufacturing: Drives three-phase motors (such as fans, water pumps, machine tools), suitable for factory production lines, food processing plants, etc.
  • Commercial Parks: Provides three-phase power (such as elevators, air conditioning systems) and lighting distribution for shopping malls, office buildings, hospitals, etc.

Municipal and Infrastructure:

  • Residential Power Distribution: Serves as a community substation, stepping down the municipal medium-voltage grid for distribution to each unit (e.g., three-phase 208V access, converted to single-phase 120V for households).
  • Transportation Hubs: Powers escalators, lighting systems, and monitoring equipment in subway stations and airports.

New Energy and Special Scenarios:

  • Distributed Generation: Acts as a grid-connected transformer in photovoltaic and wind power projects (e.g., 34.5kV step-up side) or regulates voltage in microgrids to match loads.
  • Harsh Environments: Corrosion-resistant coatings (such as zinc-nickel alloy casings) are used in coastal areas, and seismic designs (complying with UL vibration test standards) are configured in mining areas to adapt to salt spray, dust, and other environments.

Parameter:

 

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!