Key attributes

Brand Switchgear parts
Model NO. 3 Phase GRV8 -09/10 Voltage Relay
Rated frequency 45Hz-65Hz
Rated working voltage 127-265(P-N)
Series GRV8

Product descriptions from the supplier

Description

The GRV8-09/10 series is a professionally designed three-phase voltage monitoring relay that uses true RMS measurement technology to accurately monitor the voltage status of the three-phase power grid. This product is suitable for different voltage standard scenarios worldwide. Through real-time voltage protection mechanism, it effectively prevents the risk of equipment failure caused by abnormal voltage and ensures the stable operation of the power system.

Advantages of GRV8-09/10 three voltage monitoring relay products:
1. Global voltage compatibility: 8 voltage levels cover all scenarios, reducing the cost of adapting to overseas projects.
2. Industrial grade reliability: True RMS measurement technology ensures monitoring accuracy under complex working conditions.
3. Efficient operation and maintenance support: LED status indication and compact design simplify installation and maintenance processes.
4. Multiple protection mechanisms: integrated overvoltage, undervoltage, phase failure, and reverse phase comprehensive protection functions.
Product features of GRV8-09/10 three voltage monitoring relays:
1. High precision true effective value measurement
Adopting the True RMS algorithm, it has strong resistance to harmonic interference, measurement accuracy ≤ 1%, and data reliability in complex power grid environments.
2. Wide voltage adaptive design
Supports 8 adjustable rated voltages (100V~690V), compatible with mainstream industrial voltage standards worldwide, and does not require additional configuration of adapter modules.
3. Flexible wiring configuration
We offer dual specifications of three-phase three wire (3L) and three-phase four wire (4L) to adapt to different distribution system architectures.
4. Visual indication of status
Built in multi-color LED indicator lights, real-time display of relay working status (normal/overvoltage/undervoltage/phase failure), facilitating quick fault diagnosis.
5. Compact industrial design
With a width of only 36mm, it supports 35mm standard card rail installation, saving control cabinet space and suitable for high-density integration scenarios.
Application of GRV8-09/10 three voltage monitoring relay products:
1. Mobile device power monitoring
Provide voltage connection status monitoring and control protection for mobile equipment such as construction vehicles, agricultural machinery, refrigerated transport vehicles, etc.
2. Reverse operation accident protection
Real time detection of phase sequence abnormalities to prevent mechanical damage or safety accidents caused by power reversal in motor equipment.
3. Dual power automatic switching system
Used for automatic switching control between normal power supply and emergency power supply, ensuring the continuous operation of critical loads.
4. Power equipment phase failure protection
Monitor the integrity of three-phase voltage and quickly cut off the power supply in case of phase loss to avoid motor burnout and production line shutdown.

Technical parameters M460 M265
Function Monitoring 3-phase voltage
Monitoring terminals L1-L2-L3 L1-L2-L3-N
Supply terminals L1-L2-L3 L1-L2-L3-N
Voltage range 220-230-240-380-400-415-440-460(P-P) 127-132-138-220-230-240-254-265(P-N)
Rated supply frequency 45Hz-65Hz
Measuring range 176V-552V 101V-318V
Threshold adjustment voltage 2%-20% of Unselected
Adjustment of asymmetry threshold 5%-15%
Hysteresis 2%
Phase failure value 70% of Un selected 70% of Un selected
Time delay Adjustable 0.1s-10s,10%
Measurement error ≤1%
Run up delay at power up Adjustable 0.1s-10s,10%
Konb setting accuracy 10% of scale value
Supply indication green LED
Output indication red LED
Output 2×SPDT
Current rating 8A/AC1
Switching voltage 250VAC/24VDC
Min. breaking capacity DC 500mW
Temperature coefficient 0.05%/℃,at=20℃(0.05%℉,at=68℉)
Mechanical life 1×107
Electrical life(AC1) 1×105
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.