• 24kV SF6 Insulated Switchgear/Ring Main Unit/RMU
24kV SF6 Insulated Switchgear/Ring Main Unit/RMU
discuss personally
Model
RMU-24
Basic info
Brand ROCKWILL
Model NO. 24kV SF6 Insulated Switchgear/Ring Main Unit/RMU
Rated voltage 24kV
Rated frequency 50/60Hz
Series RMU
Product Detail
Products Description

Our inflatable SF6 metal seal full insulation series ring network switch cabinet has passed the type test of the national occlusal electrical testing center. Widely used in 10KV/6K power distribution system, it is the preferred switch product for various users in urban and rural areas. switch cabinet is modular unit mode, which can be combined according to different purposes. By the combination of fixed units and expandable units, which substation meets the need of compact switchgear flexible use. Inflatable ring SF6 cabinet is divided into non-expandable standard configuration and expandable standard configuration. Due to the combination of full module and half module and its own scalability, it has extremely special flexibility. SF6 inflatable ring cabinet implemented GB standard. Under the condition of the interior (20 ℃) run the design life of more than 30 years.

Feature

  • High-efficiency insulation performance: Uses SF₆ gas as the insulating medium, featuring high insulation strength. It can operate stably at the 24kV voltage level, significantly reducing the risk of short circuits.
  • Compact design: Small in size, saving installation space, especially suitable for scenarios with limited space such as urban distribution networks and industrial parks.
  • High reliability: Boasts a tightly sealed structure, providing dustproof, moisture-proof, and anti-corrosion properties. It adapts to complex environments, reduces maintenance frequency, and improves power supply continuity.
  • Excellent safety performance: Equipped with a complete interlocking protection mechanism to prevent misoperation. Meanwhile, the SF₆ gas leakage detection function ensures safe operation.
  • Flexible adaptability: Supports multiple wiring methods, enabling quick connection with transformers, cables, and other equipment to meet the topological requirements of different distribution networks.
  • Environmental protection and economy: SF₆ gas can be recycled and reused. The equipment has a long service life and low long-term operating costs, balancing environmental protection and economic benefits.
 

Environmental Conditions

  • Suitable Altitude: ≤2000mSuitable
  • Temperature: -40℃ ~ +55℃Relative
  • Humidity: Daily mean ≤95%, monthly mean ≤90%
  • Gradation of Earthquake Damage: ≤ Level 8

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!