• 230V Split Type 8 Tariffs 1P Prepaid Electricity Meter
  • 230V Split Type 8 Tariffs 1P Prepaid Electricity Meter
230V Split Type 8 Tariffs 1P Prepaid Electricity Meter
$99.00
Model
SPM-230/5(30)-SPLIT
SPM-230/5(32)-SPLIT
SPM-230/5(40)-SPLIT
SPM-230/5(45)-SPLIT
SPM-230/5(50)-SPLIT
SPM-230/5(60)-SPLIT
SPM-230/5(80)-SPLIT
SPM-230/5(100)-3SPLIT
SPM-230/5(100)-2SPLIT
SPM-230/5(100)-SPLIT
Basic info
Brand Wone
Model NO. 230V Split Type 8 Tariffs 1P Prepaid Electricity Meter
Rated voltage 230V
Rated normal current 0.25-5(100)A
Communication port support PLC/Bluetooth
Series D124065
Product Detail

Description

  • Anti-tampering

Support load ground connection, bypass detection, open cover detection, influence of external magnetic field, abnormal voltage record, two loop measurement.

  • Tariff

Divide into weekday timetable and weekend timetable, with 8 time period and 8 tariffs. Every timetable has a backup table for remote updating of backup timetable and configure the switching time. Meter will automatically switch the tariff table at the switching time.

  • Event

Open cover, magnetic field, load ground connection, reserve current, over-voltage, low-voltage, low-frequency, overload, power-fail, low remaining power, and token record.

  • Measurement

Meter measures voltage, current, active power, reactive power, frequency, power factor, MD in the current month, MD of last 1 month, MD of last 2 month, the absolute value of total active energy, the absolute value of total active tariff energy, total input energy of the current month, total input energy of last 5 month, total output energy of the current month, total output energy of last 5 month, and total reactive energy.

  • Mode

Meter has 3 operation modes: STS token mode, currency prepaid mode and post-paid (traditional) mode, which can be switched.

And the currency mode can be divided into tariff mode and step price mode. Modes can be configured through communication.

.

Specifications

Main
Range D124065
Product or Componet Type Electronic Energy Meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement


Metering type

 Prepaid Electricity Meter

Device Application

Solar Power

Energy Charge

Accuracy class 1.0 for active energy, 2.0 for reactive energy
Rated Current 5(100) A
Rated Voltage

230V

Network Frequency 50Hz
Technology Type STS
Display Type LCD 6+2 = 999999.99kW, Display when no power (press the button)
Impulse Constant

1000imp/kWh

Maximum value measured 99999.99kWh
Tariff input 8 time period and 8 tariffs
Communicatio 4G/3G/2G /PLC/Wi-Fine
CIU Communication Bluetooth/RF/PLC/
Communication protocol

DLMS/COSEM(IEC62056)

Power consumption <10VA/2W
Starting current 40mA
Output voltage 230V
Mounting Mode suspension Mounting
Mounting Support -------
Connections - terminals

-------

Standards

IEC62052-11:2003, 

IEC62053-21:2003,

IEC 62056-21,

IEC62055-41:2018



Environment
IP degree of protection

IP54

outdoor, meter can work under 70 degree

Relative humidity 5…95 % 97 °F (36 °C)
Ambient air temperature for operation -40…70 °C
Ambient Air Temperature for Storage --40…70 °C
Operating altitude 4000 m
Dimensions

Height: 207mm

Width: 121.8mm

Depth: 55.5mm

Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 250mm
Package 1 Width 150mm
Package 1 Length 70mm
Package 1 Weight 1.000kg



Dimensions


1718259137219.jpg







Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!