• 230V Split Type 8 Tariffs 1P Prepaid Electricity Meter
  • 230V Split Type 8 Tariffs 1P Prepaid Electricity Meter
  • 230V Split Type 8 Tariffs 1P Prepaid Electricity Meter
230V Split Type 8 Tariffs 1P Prepaid Electricity Meter
$99.00
Model
SPM-230/5(30)-SPLIT
SPM-230/5(32)-SPLIT
SPM-230/5(40)-SPLIT
SPM-230/5(45)-SPLIT
SPM-230/5(50)-SPLIT
SPM-230/5(60)-SPLIT
SPM-230/5(80)-SPLIT
SPM-230/5(100)-3SPLIT
SPM-230/5(100)-2SPLIT
SPM-230/5(100)-SPLIT
Basic info
Brand Wone
Model NO. 230V Split Type 8 Tariffs 1P Prepaid Electricity Meter
Rated voltage 230V
Rated normal current 0.25-5(45)A
Communication port support RF
Series D124065
Product Detail

Description

  • Anti-tampering

Support load ground connection, bypass detection, open cover detection, influence of external magnetic field, abnormal voltage record, two loop measurement.

  • Tariff

Divide into weekday timetable and weekend timetable, with 8 time period and 8 tariffs. Every timetable has a backup table for remote updating of backup timetable and configure the switching time. Meter will automatically switch the tariff table at the switching time.

  • Event

Open cover, magnetic field, load ground connection, reserve current, over-voltage, low-voltage, low-frequency, overload, power-fail, low remaining power, and token record.

  • Measurement

Meter measures voltage, current, active power, reactive power, frequency, power factor, MD in the current month, MD of last 1 month, MD of last 2 month, the absolute value of total active energy, the absolute value of total active tariff energy, total input energy of the current month, total input energy of last 5 month, total output energy of the current month, total output energy of last 5 month, and total reactive energy.

  • Mode

Meter has 3 operation modes: STS token mode, currency prepaid mode and post-paid (traditional) mode, which can be switched.

And the currency mode can be divided into tariff mode and step price mode. Modes can be configured through communication.

.

Specifications

Main
Range D124065
Product or Componet Type Electronic Energy Meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement


Metering type

 Prepaid Electricity Meter

Device Application

Solar Power

Energy Charge

Accuracy class 1.0 for active energy, 2.0 for reactive energy
Rated Current 5(100) A
Rated Voltage

230V

Network Frequency 50Hz
Technology Type STS
Display Type LCD 6+2 = 999999.99kW, Display when no power (press the button)
Impulse Constant

1000imp/kWh

Maximum value measured 99999.99kWh
Tariff input 8 time period and 8 tariffs
Communicatio 4G/3G/2G /PLC/Wi-Fine
CIU Communication Bluetooth/RF/PLC/
Communication protocol

DLMS/COSEM(IEC62056)

Power consumption <10VA/2W
Starting current 40mA
Output voltage 230V
Mounting Mode suspension Mounting
Mounting Support -------
Connections - terminals

-------

Standards

IEC62052-11:2003, 

IEC62053-21:2003,

IEC 62056-21,

IEC62055-41:2018



Environment
IP degree of protection

IP54

outdoor, meter can work under 70 degree

Relative humidity 5…95 % 97 °F (36 °C)
Ambient air temperature for operation -40…70 °C
Ambient Air Temperature for Storage --40…70 °C
Operating altitude 4000 m
Dimensions

Height: 207mm

Width: 121.8mm

Depth: 55.5mm

Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 250mm
Package 1 Width 150mm
Package 1 Length 70mm
Package 1 Weight 1.000kg



Dimensions


1718259137219.jpg







Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What are the typical connection methods for 35kV distribution lines?
What are the typical connection methods for 35kV distribution lines?
Typical Wiring Diagram of 35kV Line Radial π ConnectionWhen a 35kV line adopts a radial power grid structure, a single - side power supply or a double - side power supply radial type can be used according to the situation of the power supply points, and a loop - out interval is reserved at the end of the line.Typical Wiring Diagram of 35kV Line Radial T - ConnectionFor double - radial lines, it is advisable to select a double - side power supply. When the power supply points do not meet the r
Leon
07/18/2025
Why are the ground fault point and the accident point not at the same location?
Why are the ground fault point and the accident point not at the same location?
Fault Transfer VoltageIn low - voltage distribution systems, there is a type of personal electric shock accident where the accident occurrence point and the system fault point are not at the same location. This kind of accident occurs because after a ground fault happens elsewhere, the generated fault voltage is conducted to the metal casings of other equipment through the PE wire or PEN wire. When the fault voltage on the metal casing of the equipment is higher than the human - body safe voltag
Leon
07/18/2025
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!