• 16.5kV–27 kV Medium Voltage Metal-Clad Switchgear
16.5kV–27 kV Medium Voltage Metal-Clad Switchgear
discuss personally
Model
Masterclad™-27
Basic info
Brand POWERTECH
Model NO. 16.5kV–27 kV Medium Voltage Metal-Clad Switchgear
Rated voltage 27kV
Series Masterclad™
Product Detail

Description

The quality of Square D Masterclad™ Medium Voltage Metal-Clad Switchgear stems from a design and manufacturing process that focuses on long-term switchgear performance with the highest degree of reliability. Reliable performance and safety are enhanced by the rugged construction of Masterclad switchgear. The switchgear consists of individually grounded, compartmentalized steel structures to protect operating personnel and equipment.

Masterclad switchgear components include available state-of-the-art electronics like ION power quality monitoring and EASERGY protective relays, EcoStruxure™, integrated racking, and automatic throwover systems.

Standardization of the design incorporates a series of basic modular units, control packages, and instrumentation. For most switchgear ratings, circuit configurations, and functions, one basic size unit is used. These features provide application flexibility, versatility, and efficiency, reducing lead time and engineering time spent on planning and laying out the switchgear. 

Standard features

  • Air-insulated switchgear defined by ANSI C37.20.2

  • UL listed equipment

  • Indoor and outdoor options with one or two high breaker arrangements

  • Also available as arc resistant structurestype 2B for 5 and 15 kV class

  • Removable (drawout) circuit breaker

  • Compartmentalized enclosure with grounded barriers

  • Isolated low voltage compartment

  • Automatic gear driven shutters

  • Automatic shutters in VT, CPT, and fuse truck compartments

  • Epoxy insulated busbars

  • Mechanical interlocks

  • Disconnect style instrument transformers

  • Continuous grounded breaker and auxiliary trucks, in and between test/disconnected and connected positions

 Parameter

  • 16.5–27 kV

  • 1200–2000 Amperes Continuous Ratings

  • 16, 25, and 40 kA Symmetrical Interrupting Capacity

  • 125 kV BIL, peak (impulse) dielectric withstand

  • 60 kV, rms 1 minute 60 Hz dielectric withstand

  • NEMA Type 1 – Indoor enclosure

Structural diagram

27 kV Layout Dimensions

Know your supplier
POWERTECH
We are an electrical company that manufactures and sells high and low voltage electrical products.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$120000000
Professional Experience
7 years
Workplace
580000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!