11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)

  • 11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
  • 11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)

Key attributes

Brand ROCKWILL
Model NO. 11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
Capacity 2500kVA
Series ZGS

Product descriptions from the supplier

Description

Product overview:

The ZGS-13 Series Pad Mounted Transformer delivers a cost-effective, high-reliability, and intelligent solution for urban power distribution. This 250 kVA pad mounted transformer integrates a transformer, switchgear, fuses, tap changers, low-voltage distribution devices, and auxiliary equipment, supporting configurations for energy metering, reactive power compensation, low-voltage shunting, and more.

Designed for 50Hz/60Hz AC systems with a maximum operating voltage of 38.5kV, it suits diverse applications in industrial parks, urban residential areas, commercial centers, high-rise buildings, and other urban infrastructure.

Widely exported to North America, East Asia, Southeast Asia, and the Middle East, the series offers OEM/ODM services to meet customized needs. It complies with international and domestic standards, including ANSI C57, IEEE, DOE, CSA, IEC 60067, GB 1094, GB 17467-2010, GB/T 14048.8.1, and GB 4208.

Product Advantages

Cutting-Edge Technology

  • Fully Enclosed Insulation: Ensures safe, reliable operation with the structure isolating internal components from external hazards.

  • Optimal Performance: Features low loss, noise, and temperature rise, coupled with exceptional overload capacity and sudden short-circuit resistance.

  • Flexible Configuration: Supports both terminal and ring network systems, enabling easy conversion to enhance power supply reliability.

  • Cost-Efficient Operation: Requires minimal maintenance, offers user-friendly operation, and reduces overall equipment costs.

Enclosure Design

  • Premium Materials: Constructed from cold-rolled high-quality hot-dip galvanized steel sheets for corrosion resistance.

  • Precision Manufacturing: Laser CNC cutting, drilling, and bending ensure mm-level processing accuracy.

  • Durable Coating: Surface treated with electrostatic spray paint, guaranteeing 30+ years of anti-aging performance.

  • Core Component: Integrates low-loss oil-immersed transformers manufactured by WONE Electric for stable energy conversion.

Processing & Assembly Standards

  • Skilled Workforce: Assembly technicians undergo at least 6 months of specialized training.

  • Automated Wiring: Secondary circuits are cut by automatic equipment to ensure wiring reliability.

  • Torque Control: Bolts are tightened with power tools to meet precise torque specifications.

  • Busbar Fabrication: Copper busbars are CNC-punched and bent for consistent conductivity.

  • Rigorous Testing: Comprehensive pre-delivery inspections ensure seamless on-site operation.

Company Strengths

  • Certifications: Holds authoritative credentials including ISO, CE, CB, UL, etc.

  • Quality System: Implements a perfect SQA management system to maintain product excellence.

  • Comprehensive Services: Provides quick quotation, electrical design support, and OEM/ODM customization.

  • Logistics Efficiency: Ensures short lead times and global delivery capabilities.

  • After-Sales Support: Offers a full-service warranty system, including factory visits for quality verification.

Product parameters:

Rated Voltage: 10kV, 11kV, 13.8kV, 20kV, 33kV, 34.5kV, 35kV
Maximum Operating Voltage: 38.5kV

Operating Conditions

Temperature Parameters

  • Maximum daily temperature: 40°C

  • Minimum daily temperature: -25°C

  • Maximum daily temperature difference: 25K

  • Average temperature of hottest month: 30°C

  • Maximum annual average temperature: 20°C

  • Average daily relative humidity: ≤95%

  • Average monthly relative humidity: ≤90%

  • Altitude: ≤1000m

  • Solar Radiation Intensity: 0.1W/cm²

  • Maximum Ice Thickness: 10mm

  • Wind Speed (10m Height, 10min Average): 35m/s

  • Ground Horizontal Acceleration: 2m/s²

  • Installation Environment: Outdoor

  • Pollution Grade: Ⅲ

Ordering Instructions

When placing an order, customers are required to provide the following information to ensure precise customization:

Electrical Diagrams

Main loop scheme di:agram and secondary loop system diagram.

Auxiliary circuit electrical schematic diagram and wiring terminal layout.

Mechanical Drawings:

Equipment layout drawing, combination drawing, and floor plan.

Component Specifications:

Brand, model, specification, and quantity of main electrical components.

Cabling Details:

Incoming and outgoing line configurations and cable specifications.

Surface Finishing:

Equipment surface color (specified by RAL chromatic number).

Special Requirements:

Any additional customizations can be negotiated with WONE Electric for tailored solutions.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.