• 11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
11kV 20kV 35KV Pad Mounted Transformer(Prefabricated Substation)
discuss personally
Model
ZGS-13/1000
ZGS-13/2000
ZGS-13/2500
ZGS-13/250
Basic info
Brand ROCKWILL
Model NO. ZGS-13 Series Pad Mounted Transformer
Capacity 1000kVA
Series ZGS
Product Detail

Product overview:

The ZGS-13 Series Pad Mounted Transformer delivers a cost-effective, high-reliability, and intelligent solution for urban power distribution. This 250 kVA pad mounted transformer integrates a transformer, switchgear, fuses, tap changers, low-voltage distribution devices, and auxiliary equipment, supporting configurations for energy metering, reactive power compensation, low-voltage shunting, and more.

Designed for 50Hz/60Hz AC systems with a maximum operating voltage of 38.5kV, it suits diverse applications in industrial parks, urban residential areas, commercial centers, high-rise buildings, and other urban infrastructure.

Widely exported to North America, East Asia, Southeast Asia, and the Middle East, the series offers OEM/ODM services to meet customized needs. It complies with international and domestic standards, including ANSI C57, IEEE, DOE, CSA, IEC 60067, GB 1094, GB 17467-2010, GB/T 14048.8.1, and GB 4208.

Product Advantages

Cutting-Edge Technology

  • Fully Enclosed Insulation: Ensures safe, reliable operation with the structure isolating internal components from external hazards.

  • Optimal Performance: Features low loss, noise, and temperature rise, coupled with exceptional overload capacity and sudden short-circuit resistance.

  • Flexible Configuration: Supports both terminal and ring network systems, enabling easy conversion to enhance power supply reliability.

  • Cost-Efficient Operation: Requires minimal maintenance, offers user-friendly operation, and reduces overall equipment costs.

Enclosure Design

  • Premium Materials: Constructed from cold-rolled high-quality hot-dip galvanized steel sheets for corrosion resistance.

  • Precision Manufacturing: Laser CNC cutting, drilling, and bending ensure mm-level processing accuracy.

  • Durable Coating: Surface treated with electrostatic spray paint, guaranteeing 30+ years of anti-aging performance.

  • Core Component: Integrates low-loss oil-immersed transformers manufactured by WONE Electric for stable energy conversion.

Processing & Assembly Standards

  • Skilled Workforce: Assembly technicians undergo at least 6 months of specialized training.

  • Automated Wiring: Secondary circuits are cut by automatic equipment to ensure wiring reliability.

  • Torque Control: Bolts are tightened with power tools to meet precise torque specifications.

  • Busbar Fabrication: Copper busbars are CNC-punched and bent for consistent conductivity.

  • Rigorous Testing: Comprehensive pre-delivery inspections ensure seamless on-site operation.

Company Strengths

  • Certifications: Holds authoritative credentials including ISO, CE, CB, UL, etc.

  • Quality System: Implements a perfect SQA management system to maintain product excellence.

  • Comprehensive Services: Provides quick quotation, electrical design support, and OEM/ODM customization.

  • Logistics Efficiency: Ensures short lead times and global delivery capabilities.

  • After-Sales Support: Offers a full-service warranty system, including factory visits for quality verification.

Product parameters:

Rated Voltage: 10kV, 11kV, 13.8kV, 20kV, 33kV, 34.5kV, 35kV
Maximum Operating Voltage: 38.5kV

Operating Conditions

Temperature Parameters

  • Maximum daily temperature: 40°C

  • Minimum daily temperature: -25°C

  • Maximum daily temperature difference: 25K

  • Average temperature of hottest month: 30°C

  • Maximum annual average temperature: 20°C

  • Average daily relative humidity: ≤95%

  • Average monthly relative humidity: ≤90%

  • Altitude: ≤1000m

  • Solar Radiation Intensity: 0.1W/cm²

  • Maximum Ice Thickness: 10mm

  • Wind Speed (10m Height, 10min Average): 35m/s

  • Ground Horizontal Acceleration: 2m/s²

  • Installation Environment: Outdoor

  • Pollution Grade: Ⅲ

Ordering Instructions

When placing an order, customers are required to provide the following information to ensure precise customization:

Electrical Diagrams

Main loop scheme di:agram and secondary loop system diagram.

Auxiliary circuit electrical schematic diagram and wiring terminal layout.

Mechanical Drawings:

Equipment layout drawing, combination drawing, and floor plan.

Component Specifications:

Brand, model, specification, and quantity of main electrical components.

Cabling Details:

Incoming and outgoing line configurations and cable specifications.

Surface Finishing:

Equipment surface color (specified by RAL chromatic number).

Special Requirements:

Any additional customizations can be negotiated with WONE Electric for tailored solutions.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Ensuring Reliability: A Deep Dive into Transformer Maintenance
Ensuring Reliability: A Deep Dive into Transformer Maintenance
IntroductionElectric transformers are the backbone of modern power distribution systems, silently enabling the reliable delivery of electricity to homes, businesses, and industries. As these critical assets age and the demand for uninterrupted power grows, the importance of diligent transformer maintenance has never been greater. This essay explores the essential role of transformer maintenance, highlighting the value of proactive care, the impact of advanced diagnostic technologies, and the tra
Vziman
09/03/2025
How does a transformer work?
How does a transformer work?
Transformer Operation PrincipleA transformer is an electrical device that operates on the principle of electromagnetic induction to transfer electrical energy from one circuit to another. It enables the adjustment of voltage levels within an alternating current (AC) system, either stepping up (increasing) or stepping down (decreasing) voltage while maintaining the same frequency.Working Principle:Basic ComponentsA transformer consists of two coils, known as windings—the "primary winding" connect
Rockwell
09/03/2025
Constant testing of high-voltage cable lines
Constant testing of high-voltage cable lines
1. Definition of High-Voltage Cable Line Constant TestingHigh-voltage cable line constant testing refers to the systematic measurement, using specialized instruments, of electrical parameters such as resistance, inductance, capacitance, and conductance before a cable line is commissioned or after major maintenance. The aim is to obtain fundamental data characterizing the electromagnetic properties of the cable, serving as a critical testing phase that provides accurate parameter support for powe
Oliver Watts
09/03/2025
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
Technical Analysis of 220 kV High-Voltage Cable Construction in Winter
1.Work Environment Requirements and Safeguard MeasuresBased on technical requirements for cable equipment storage, laying, transportation, laying, transposition, testing, and cable terminations, the project owner and construction units have conducted extensive trials and implemented protective measures regarding ambient temperature, humidity, bending radius, traction control, and route optimization. These measures ensure high-voltage cable quality and on-site safety under harsh winter conditions
James
09/03/2025
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.