Wavelet Analysis of Transformer Inrush Current

Echo
Field: Transformer Analysis
China

During operation, transformers may generate magnetizing inrush currents due to various factors. These inrush currents not only affect the normal operation of the transformer but may also compromise the stability of the power system. Therefore, accurately identifying transformer magnetizing inrush current is crucial for effectively suppressing such inrush.

Next, let's explore how wavelet theory is applied in analyzing transformer magnetizing inrush current. Wavelet analysis is a method that provides localization in both time and frequency domains, making it highly effective in processing non-stationary signals. The fundamental idea of wavelet transform is to decompose a signal into wavelet components at different frequency and time scales, which are then analyzed and processed.

Transformer magnetizing inrush current is a transient high-current phenomenon caused by sudden changes in voltage or current. Its characteristics mainly include nonlinearity, non-stationarity, periodicity, and randomness. These features make traditional current analysis methods face significant challenges when dealing with transformer magnetizing inrush currents. In comparison, wavelet theory offers four key advantages in the analysis of transformer inrush current:

  • Signal Denoising: Since magnetizing inrush current signals contain substantial noise, denoising is necessary. Wavelet analysis enables multi-scale decomposition of the signal, followed by thresholding of wavelet coefficients at each scale, effectively removing noise.

  • Signal Reconstruction: Wavelet analysis not only denoises signals but also enables signal reconstruction. By selecting an appropriate wavelet basis function and thresholding method, it can effectively preserve the main signal features while eliminating noise.

  • Feature Extraction: Wavelet analysis can effectively extract features of magnetizing inrush current. By applying wavelet transform, the energy distribution of the signal across different frequency and time scales can be obtained, allowing for the identification of key signal characteristics.

  • Fault Diagnosis: By comparing inrush current signals under normal and faulty conditions, differences can be identified to enable fault diagnosis. Wavelet analysis effectively highlights these differences, thereby improving the accuracy of fault detection.

Wavelet theory provides a powerful tool for analyzing transformer magnetizing inrush current. Through wavelet analysis, tasks such as denoising, reconstruction, feature extraction, and fault diagnosis of inrush currents can be achieved, thereby enhancing the operational safety of transformers and the stability of power systems.

Give a tip and encourage the author!

Recommended

What’s the Difference Between Rectifier Transformers and Power Transformers?
What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
01/29/2026
How to Judge, Detect and Troubleshoot Transformer Core Faults
1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
01/27/2026
Analysis of Four Major Power Transformer Burnout Cases
Case OneOn August 1, 2016, a 50kVA distribution transformer at a power supply station suddenly sprayed oil during operation, followed by burning and destruction of the high-voltage fuse. Insulation testing revealed zero megohms from the low-voltage side to ground. Core inspection determined that damage to the low-voltage winding insulation had caused a short circuit. Analysis identified several primary causes for this transformer failure:Overloading: Load management has historically been a weak
12/23/2025
Power Transformer Condition Monitoring: Reducing Outages & Maintenance Costs
1. Definition of Condition-Based MaintenanceCondition-based maintenance refers to a maintenance approach where repair decisions are determined by the real-time operational status and health condition of equipment. There are no fixed schedules or predetermined maintenance dates. The prerequisite for condition-based maintenance is the establishment of equipment parameter monitoring systems and comprehensive analysis of various operational information, enabling reasonable maintenance decisions base
12/22/2025