• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Stirling Boiler

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

WechatIMG1834.jpeg

Stirling Boiler is one of the most basic variety of bent tube boiler. In most of the modern thermal power generating plants we use bent tube boiler. Stirling Boiler is one of the largest capacity boiler. A Stirling Boiler can generate as high as 50,000 kg steam per hour and can produce pressure as high as 60 kgf per cm2. This boiler was first designed in the year of 1888 by Alan Stirling so we refer the boiler as Stirling Boiler. Because of the huge capacity we can use this boiler in central power stations.

In Stirling Boiler there are three steam drums and two mud drums. Three steam drums are placed on the top portion of the boiler system structure and two mud drums are placed on bottom of the structure. The top steam drums are connected to the bottom mud drums with banks of bent tubes. Since the tubes are bent, the mechanical stresses due to expansion of the pipes during heating can not effect the system much. The steam drums, mud drums and bent tubes are made of steel. Also still structure is used to support the entire system.

The entire system is enclosed by a brickwork. Here the brick enclosure is used to prevent the heat dissipation to the surroundings. The fire door is constructed at the bottom side of the brick enclosure wall. The damper is provided on the other side of the brick enclosure wall to take out the combustion gas as when required.

The fire brick arch is provided above the furnace. Three baffles are provided in the boiler system to allow the combustion gas to flow in zigzag way. There is one water circulating tubes connecting the mud drums. Also there are steam circulating tubes connecting middle steam drums to outer steam drums. There is also a group of hot water circulating tube from front steam drum to middle steam drum.

A safety value is provided on the back steam drum. Finally the steam is collected from middle steam drum. The steam compartment is constructed inside the middle steam drum. The super heater is connected to steam compartment through a steel pipe.
stirling boiler

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.