Trihal Cast resin transformer up to 36kV

  • Trihal Cast resin transformer up to 36kV
  • Trihal Cast resin transformer up to 36kV
  • Trihal Cast resin transformer up to 36kV

Key attributes

Brand Schneider
Model NO. Trihal Cast resin transformer up to 36kV
Rated voltage 12/17.5kV
Series Trihal

Product descriptions from the supplier

Description

Product at a glance

Cast resin, 50 Hz, three-phased distribution transformers with the following characteristics:

  • Indoor use / Outdoor use with properly designed enclosure

  • Thermal class F - Temperature rise 100

  • Ambient ≤ 40°C, altitude ≤ 1000 m

  • MV windings encapsulated in cast resin

  • Pre-impregnated LV windings

  • Natural air cooling system (AN type)

  • Core and frame covered with protective coating

  • Anti-corrosion surface treatment : corrositivity category class C2, “Medium” durability (according to ISO 12944-2)

 

The components of the products

 

 

Compliance:
These transformers comply with standards:

  • IEC 60076-11

  •  EN 50588-1

Schneider Electric guarantees that its transformers are silicone free and certified:

  •  C3* Climatic class

  •  E3 Environment class according to IEC 60076-16

  • F1 Fire behaviour class

  • Almost partial discharge free -Acceptance level:

  • ≤ 10 pC Routine Test
    - ≤ 5 pC Special Test according to IEC 60076 standard
    * C2 Thermal shock test carried out at -50°C

 

Trihal
Up to 3150 kVA, 12 kV, losses

Main electrical characteristics 

Dimensions* and weights

Without enclosure (IP00) 

 

With IP31 metal enclosure

 

 

Trihal
Up to 3150 kVA, 17.5 to 24 kV, losses

Main electrical characteristics 

 

Dimensions* and weights

Without enclosure (IP00) 

 

With IP31 metal enclosure

 

Trihal
Up to 3150 kVA, 36 kV, losses

Main electrical characteristics 

 

Dimensions* and weights

Without enclosure (IP00) 

 

With IP31 metal enclosure

 

All available Trihal technical range

 


Trihal
Options and accessories 

High voltage surge arresters

If the installation is likely to be subjected to overvoltage of any kind (atmospheric or switching), the transformer must be protected by phase-to-earth surge arresters, installed directly on the transformer’s HV connection terminals (either at the top or the bottom).
It is essential to install these surge arresters:

  •  where the lightning impact level Nk is greater than 25. The risk of direct or induced atmospheric overvoltage is directly proportional to Nk

  •  during occasional switching (less than 10 operations a year) of a transformer with a weak load, or during a magnetization phase. It is also highly recommended to install them: where the substation is supplied by a network including overhead parts, then a
    cable longer than 20 m (case of an overhead-underground network) Surge arresters can be installed in an IP 31 enclosure, or even on existing equipment, provided that insulation distances are adhered to. 

                            High voltage surge arresters on the lower part

 

 

Vibration damping
Roller anti-vibration pads
This accessory, placed under the rollers, avoids vibrations being transmitted from the transformer to its environment.
Damper unit
This device is installed instead of the roller and enables transmission of vibrations to the transformer environment to be attenuated.

 

 

            Anti-damping accessories 

 

Protective Enclosure

The IP and IK protective indices refer to the following criteria:

IP protection indices

 

          Protective enclosure IP31, IK7

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 20000m² Total staff: Highest Annual Export(usD): 400000000
Workplace: 20000m²
Total staff:
Highest Annual Export(usD): 400000000
Services
Business Type: Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • EcoStruxure™ Connected solutions
    What is EcoStruxure™ ?EcoStruxure™ is our open, interoperable, IoT-enabled system architectureand platform. EcoStruxure delivers enhanced value around safety, reliability,efficiency, sustainability, and connectivity for our customers. EcoStruxureleverages advancements in IoT, mobility, sensing, cloud, analytics, andcybersecurity to deliver Innovation at Every Level. This includes ConnectedProducts, Edge Control, and Apps, Analytics & Services, which are supported byCustomer Lifec
    04/23/2025
  • RM6 SeT Digital solutions
    Digital solutionsDistributed DTU Easergy T300Comprehensive features and flexbile scalabilityTailored to meet future operational challenges ofdistribution network automationApplications range from monitoring rooms tomedium and low voltage distribution stationsTH110-R cable joint temperature measurementWireless passive, easy to installDirect measurement of conductor temperaturewith high accuracyPD110 series local discharge test deviceReal-time monitoring of equipment corona andpartial discharge st
    04/30/2025
  • Your trusted partner for wind turbine and wind farm solutions
    Solutions overviewControl of the wind turbineEnsure an optimized operating environmentGain greater control of the turbine through automation and backup powerChoosing the most efficient wind turbine is the key to success. Schneider Electric offers a fully automated wind turbine with the programmablelogic controller (PLC) and a highly-reliable UPS. They have a very low power consumption, and can be easily modified or upgraded.As such, the PLC functions as the “brain” of the wind turbin
    05/05/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.