• RWB-400Z Series digital microcomputer protection device
RWB-400Z Series digital microcomputer protection device
discuss personally
Model
RWB-400Z
Basic info
Brand RW Energy
Model NO. RWB-400Z Series digital microcomputer protection device
Rated voltage 230V ±20%
Rated frequency 50(Hz)
Electric energy consumption ≤10W
Rated current in 5A or 1A
Series RWB
Product Detail

Description :

RWB-200 Series digital microcomputer protection device is suitable for low current/small resistance grounding system of 35kV and below, which integrates functions of protection、control、communication and monitor. The device uses component programmable design ideas to reduce maintenance workload and spare parts. It can flexibly meet the needs of a variety of applications, and is the ideal replacement production for traditional electromagnetic relay protection. 

Main function introduction:

  • Main protection relay functions: three stages phase-current protection, zero-sequence current protection, Negative sequence current protection, inverse-time protection, overload component, reclosing, frequency protection, undervoltage/overvoltage protection, zero sequence phase overvoltage protection, Motor start fast break protection, Negative sequence overcurrent, overheat protection.

  • Control functions: Lockout, circuit-breaker control.

  • Communication functions: Using the RS485 interface of the device passing Modbus RTU Communication protocol link to ‌SCADA system; realizable Events\Faults and Measurands viewing, executing remote command, Time synchronizing, Viewing and Changing Settings

  • Data Storage functions: Event Records, Fault Records, Measurands.

  • Remote signaling remote measuring, remote controlling function can be customized address.

Technology parameters:

image.png

image.png

    

Device structure:

image.png


Device terminal definition diagram:

企业微信截图_17373630681818.png

Installation Diagram:

942d85ff5d950feec830a21c5f20e52f(1).jpg


Know your supplier
RW Energy
Zhejiang Rockwell Energy Technology Co., Ltd. is an international enterprise specializing in the research, development and manufacturing of recloser controllers, power quality management, power monitoring systems and other high-end power equipment. In today's critical period of global energy transition and power system upgrading, the company has gathered a group of top talents in the fields of power engineering, automation control, software development, etc., who carry the enthusiasm and persistence for the power business, and are committed to overcoming the complex problems in the power system, and promoting the intelligent development of the power industry with innovative technology. Mission: To make global electricity smarter, more reliable and more efficient with innovative technology. Vision: To be the leader in global power intelligence.
Main Categories
High voltage/New energy/Tester
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$100000000
Professional Experience
12 years
Workplace
30000m²
占位
占位
Documents
Restricted.
RWB series Microcomputer protection device
Manual English
Consulting
Related Products
Related Knowledges
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What are the common faults of low-voltage voltage transformers?
What are the common faults of low-voltage voltage transformers?
1. Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In lo
Oliver Watts
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!