RDC5 series 380/400V AC contactor

  • RDC5 series 380/400V AC contactor

Key attributes

Brand Wone Store
Model NO. RDC5 series 380/400V AC contactor
Rated voltage 380/400V
Rated frequency 50/60Hz
Series RDC5

Product descriptions from the supplier

Description

Product Description

RDC5 series AC contactors are mainly used in circuits with AC 50HZ rated operating voltage to 690V rated working current up to 95A It is used for long-distance connection and disconnection of circuits, and can be directly plugged into the thermal relay to form an electromagnetic starter to protect against possible occurrences Operate overloaded circuits. The contactor can also be assembled with building block-type auxiliary contact groups, air delay heads, mechanical interlocking mechanisms and other accessories. It is composed of a delay contactor, a reversible contactor, and a star triangle starter. The products comply with: GB/T14048.4, IEC 60947-4-1 and other national standards.

Feature

  • Wide range of operating voltage and current: Mainly used in circuits with AC 50Hz, rated operating voltage up to 690V, and rated operating current up to 95A, which can meet the needs of various circuits.

  • Diversified functions: It can remotely connect and disconnect circuits, and can also be directly plugged with thermal relays to form an electromagnetic starter, which is used to protect circuits that may have operating overloads. In addition, it can be assembled with accessories such as modular auxiliary contact sets, air delay heads, and mechanical interlocking mechanisms to form delay contactors, reversible contactors, star-delta starters, etc.

  • Compliance with multiple standards: The product complies with national standards such as GB/T14048.4 and IEC 60947-4-1, ensuring reliable quality and performance.

  • Strong environmental adaptability: Suitable for 8-hour duty cycle, intermittent periodic duty cycle, continuous duty cycle and short-time duty cycle, and can work stably under various environmental conditions.

  • High protection level: With a protection level of IP20, it can effectively prevent the intrusion of foreign objects.

Parameters

Contactor Model

RDC5 - 06

RDC5 - 09

RDC5 - 12

RDC5 - 18

RDC5 - 25

RDC5 - 32

RDC5 - 38

RDC5 - 40

RDC5 - 50

RDC5 - 65

RDC5 - 80

RDC5 - 95

Poles

3 poles

Rated Insulation Voltage (Ui) V

690

Rated Operating Voltage (Ue) V

380/400, 660/690

Conventional Heating Current (Ith) A

16

25

25

32

40

50

50

50

60

80

110

110

Rated Operating Current (Ie)

AC - 3 380/400V A

6

9

12

18

25

32

38

40

50

65

80

95

AC - 3 660/690V A

3.8

6.6

8.9

12

18

22

22

34

39

42

49

49

AC - 4 380/400V A

2.6

3.5

5

7.7

8.5

12

14

18.5

24

28

37

44

AC - 4 380/400V A

1

1.5

2

3.8

4.4

7.5

8.9

9

12

14

17.3

21.3

Rated Operating Power (Pe)

AC - 3 380/400V kw

2.2

4

5.5

7.5

11

15

18.5

18.5

22

30

37

45

AC - 3 660/690V kw

3

5.5

7.5

10

15

18.5

18.5

30

33

37

45

45

AC - 4 380/400V kw

1.1

1.5

2.2

3.3

4

5.4

5.5

7.5

11

15

18.5

22

AC - 4 660/690V kw

0.75

1.1

1.5

3

3.7

5.5

6

7.5

10

11

15

18.5

Mechanical Life (10,000 times)

1200

1200

1200

1200

1200

1000

1000

1000

900

900

650

650

Electrical Life

AC - 3 (10,000 times)

110

110

110

110

110

90

90

90

90

90

65

65

AC - 4 (10,000 times)

22

22

22

22

22

22

22

17

17

17

11

11

Operating Frequency

AC - 3 (times/hour)

1200

1200

1200

1200

1200

600

600

600

600

600

-

-

AC - 4 (times/hour)

-

-

-

-

-

300

300

300

300

300

-

-

Normal Operating Conditions and Installation Conditions

  • Temperature: -25°C ~ +55°C, can reach +70°C for a short time (24h);

  • Relative humidity: ≤ 90%;

  • The product should be handled with care during transportation, not inverted, and strong collisions should be avoided;

  • The product shall not be exposed to rain or snow during transportation and storage.

  • The installation position should be vertical, and the inclination in all directions should not exceed ±22.5°;

  • Installed in a place without impact vibration and without rain or snow;

  • Pollution degree: Class 3;

  • Installation category: Category III;

  • Rated impulse withstand voltage Uimp: 8000V;

  • Rated frequency: 50Hz;

  • Protection class: IP20;

  • Suitable for 8h duty cycle, intermittent periodic duty cycle, uninterrupted duty cycle and short-time duty cycle.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.