• Prepayment Smart Energy Meters Can Operate the Recharging
  • Prepayment Smart Energy Meters Can Operate the Recharging
  • Prepayment Smart Energy Meters Can Operate the Recharging
Prepayment Smart Energy Meters Can Operate the Recharging
$90.00
Model
SPM-240/5(30)-2CHARGE
SPM-240/5(32)-2CHARGE
SPM-240/5(40)-2CHARGE
SPM-240/5(45)-2CHARGE
SPM-240/5(50)-2CHARGE
SPM-240/5(100)-2CHARGE
SPM-240/5(30)-1CHARGE
SPM-240/5(32)-1CHARGE
SPM-240/5(40)-1CHARGE
SPM-240/5(45)-1CHARGE
SPM-240/5(50)-1CHARGE
SPM-240/5(100)-1CHARGE
SPM-240/5(80)-2
SPM-240/5(80)
Basic info
Brand Wone
Model NO. Prepayment Smart Energy Meters Can Operate the Recharging
Rated voltage 240V
Rated normal current 5(32)A
Rated frequency 50(Hz)
Methods of Communication LoRa
Series K019-04
Product Detail

Description

The meter has 3 operation modes: STS token mode, currency prepayment mode and postpayment mode, which can be switched through communication. Self-diagnosis: EEPROM check, low battery alarm, relay status detection. LCD display is adopted, and the housing of the energy meter is made of flame-retardant PC material.

Features

  • Support load ground connection, switch detection, influence of external magnetic field, abnormal voltage record.

  •  Anti-tamper when Neutral missing:when Neutral missing, the meter still can workbattery support

  • Divide into weekday timetable and weekend timetable, with 8 time period and 8 tariffs. Every timetable has a backup table for remote updating of backup timetable and configure the switching time. Meter will automatically switch the tariff table at the switching time.

  • Meter support IR,RS485/LoRa, baud-rate: 9600/PLC, baud-rate: 4800.

  • Open cover, magnetic field, load ground connection, reserve current, over-voltage, low-voltage, low-frequency, overload, power-fail, low remaining power, and token record.

  • Meter measures voltage, current, active power, reactive power, frequency, power factor, MD in the current month, MD of last 1 month, MD of last 2 month, the absolute value of total active energy, the absolute value of total active tariff energy, total input energy of the current month, total input energy of last 5 month, total output energy of the current month, total output energy of last 5 month, and total reactive energy.

  •  Meter has 3 operation modes: STS token mode, currency prepaid mode and post-paid (traditional) mode, which can be switched.

  • And the currency mode can be divided into tariff mode and step price mode. Modes can be configured through communication.

  • Enter 20-digit token via keypad of meter or IHD, the meter display will be green Pic 1 if recharging is successful, will be red Pic 2 if is failed.

Specifications

Main
Range K019-04
Product or Componet Type Energy meter
Country of origin China
Complementary
Phase Single Phase
Type of measurement

----

Metering type

Measurement

Device Application

Energy Charge

Accuracy class Active power 1.0 
Rated Current 5(80)A

Rated Voltage

240V

Network Frequency 50-60Hz
Technology Type Electronic
Display Type LCD display(LCD 6+2 = 999999.99kWh)
Impulse Constant

1000imp/kWh(LED)   1000imp/kvarh

Maximum value measured 99999.99kWh
Tariff input ---
Communication port protocol DLMS/COSEM(IEC62056)
Communication port support RS485/LoRa
Local signalling

------

Number of inputs -------
Number of Outputs --------------
Output voltage 230V
Mounting Mode --
Mounting Support -----
Connections - terminals

-----

Standards

  IEC62052-11 2003, IEC62053-21 2003



Environment
IP degree of protection

IP54

Relative humidity <95%
Ambient air temperature for operation -20…70 °C
Ambient Air Temperature for Storage --30…80 °C
Operating altitude ---
Dimensions 207*120*55.5mm
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 57mm
Package 1 Width 122mm
Package 1 Length 209mm
Package 1 Weight 1.000kg



Connection Diagram

image.png



Dimensions


image.png









Know your supplier
Wone
Main Categories
High voltage/Low voltage/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!