• JW10 Series HV Grounding Switch
JW10 Series HV Grounding Switch
discuss personally
Model
JW10-550
JW10-420
JW10-363
JW10-252
JW10-170
JW10-145
JW10-126
JW10-72.5
JW10-40.5
Basic info
Brand Wone
Model NO. JW10 Series Grounding Switch
Rated voltage 420kV
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series JW10 Series
Product Detail

Product introduction

JW10 series high voltage grounding switch is an outdoor high voltage power transmission equipment of three phase alternating frequency 50Hz/60Hz, which is used to release electrostatic charge of the inspected circuit and equipment and conduct electric sale earthing of inspected busbar and high voltage equipment’s such as breakers to make earthing opening and closing symbol visible in the circuit and guarantee the personal safety of maintenance personnel, it is generally used in places where single pole vertical fracture disconnection switch is adopted to ground the upper level busbar

JW10 series grounding switch can be attached on switch disconnector such as GW4C, GW6B, GW7B, GW22B and GW23B. it can also form independent grounding switch.JW10-40.5、72.5、126、 252 model adopts SRCC type manual operation mechanism or SRCJ3 type electromotor operation mechanism to conduct tripolar link operation.JW10-363,550 model grounding switch uses SRCJ2 type electromotor operation mechanism to conduct single pole link operation, it can also realize tripolar electric link.

The grounding switch possesses the capacity of opening and closing induction current which meeting the national standard and B Grade of the industrial standard, which is applicable to the input & output end terminal earthing of converting station of double circuit parallel overhead transmission line.

The grounding switch has possessed the national technical appraisement of new products organized by China Mechanical industry Association, The appraisement shows that the product structure and functions met the complete requirements of disconnecting switch. The product performance reaches the advanced level of world similar products.

JW10 series grounding switch is composed of three single pole and operation mechanism, Each single pole includes foundation, support insulator and earthing conducting rod. The earthing conducting rod is installed on the foundation and the fixed contact is installed on the top of support insulator.

The operation mechanism snape in or inserts in the fixed contact to realize switching on of grounding switch through driving element driving the earthing conducting rod to swing upward, The switching off operation is on the contrary.

Main characteristic

1、 The conductive arm is made of high strength aluminum alloy sections, which has good electrical conductivity, high mechanical strength, light weight and strong anti-corrosion capacity.

2、 Reliable contact structure: JW10-40 5、72.5、126、252 type grounding switch is one-step movement structure with inserted contact which is simple in structure and convenient in maintenance The structure makes effective use of electrodynamic force to intensify the contact and keep the earthing knife switch on the switching on location, which possesses good capacity of hearing short circuit current It is also in possession of the capacity of B grade induction current which meets national standard

3、 JW10-83, 550 type grounding switch is in single arm vertical & open type with inserted type contact which is simple in structure. Two-step movement is required in switching on of earthing conductive rod. When switching on, rotate the switch upward to the fixed contact and direct act to insert into the quincuncial contact. The contact is reliable and the capacity of bearing short circuit current is strong; After installing subsidiary loop and vacuum switch, its parameters of opening and closing induction current reach the domestic leading level: electromagnetic induction current: 1250A, 35kV;electrostatic induction current: 50A, 50kV.

4、 Provide one-key sequential control "double confirmation" function expansion.

Main technical parameters

JW10-parameters.png

Order notice 

Product model, rated voltage, rated current, rated short-time withstand voltage and creep distance, etc. shall be specified when ordering Products

Arrangement method of 126-252 kV grounding switch shall be specified - parallel type or one column type;

If the grounding switch requires opening and closing induction current, special specifications and required parameters of opening and closing induction current shall be provided. The side of grounding switch which requires opening and dosing induction current of the disconnector switch shall be specified: (Ps. Only grounding switches used in the input & output circuit of converting station of two circuit parallel transmission line require the function of opening and closing induction current, which is only a minority, Not all the grounding switches and disconnect switches require opening and closing induction current.)

Model of operation mechanism, motor voltage, control voltage and auxiliary switch contact number.


Know your supplier
Wone
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$50,000,000
Professional Experience
1 years
Workplace
65666m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!