JW10 Series HV Grounding Switch

  • JW10 Series HV Grounding Switch

Key attributes

Brand Wone Store
Model NO. JW10 Series Grounding Switch
Rated voltage 126kV
Rated frequency 50/60Hz
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series JW10 Series
Description

Product introduction

JW10 series high voltage grounding switch is an outdoor high voltage power transmission equipment of three phase alternating frequency 50Hz/60Hz, which is used to release electrostatic charge of the inspected circuit and equipment and conduct electric sale earthing of inspected busbar and high voltage equipment’s such as breakers to make earthing opening and closing symbol visible in the circuit and guarantee the personal safety of maintenance personnel, it is generally used in places where single pole vertical fracture disconnection switch is adopted to ground the upper level busbar

JW10 series grounding switch can be attached on switch disconnector such as GW4C, GW6B, GW7B, GW22B and GW23B. it can also form independent grounding switch.JW10-40.5、72.5、126、 252 model adopts SRCC type manual operation mechanism or SRCJ3 type electromotor operation mechanism to conduct tripolar link operation.JW10-363,550 model grounding switch uses SRCJ2 type electromotor operation mechanism to conduct single pole link operation, it can also realize tripolar electric link.

The grounding switch possesses the capacity of opening and closing induction current which meeting the national standard and B Grade of the industrial standard, which is applicable to the input & output end terminal earthing of converting station of double circuit parallel overhead transmission line.

The grounding switch has possessed the national technical appraisement of new products organized by China Mechanical industry Association, The appraisement shows that the product structure and functions met the complete requirements of disconnecting switch. The product performance reaches the advanced level of world similar products.

JW10 series grounding switch is composed of three single pole and operation mechanism, Each single pole includes foundation, support insulator and earthing conducting rod. The earthing conducting rod is installed on the foundation and the fixed contact is installed on the top of support insulator.

The operation mechanism snape in or inserts in the fixed contact to realize switching on of grounding switch through driving element driving the earthing conducting rod to swing upward, The switching off operation is on the contrary.

Main characteristic

1、 The conductive arm is made of high strength aluminum alloy sections, which has good electrical conductivity, high mechanical strength, light weight and strong anti-corrosion capacity.

2、 Reliable contact structure: JW10-40 5、72.5、126、252 type grounding switch is one-step movement structure with inserted contact which is simple in structure and convenient in maintenance The structure makes effective use of electrodynamic force to intensify the contact and keep the earthing knife switch on the switching on location, which possesses good capacity of hearing short circuit current It is also in possession of the capacity of B grade induction current which meets national standard

3、 JW10-83, 550 type grounding switch is in single arm vertical & open type with inserted type contact which is simple in structure. Two-step movement is required in switching on of earthing conductive rod. When switching on, rotate the switch upward to the fixed contact and direct act to insert into the quincuncial contact. The contact is reliable and the capacity of bearing short circuit current is strong; After installing subsidiary loop and vacuum switch, its parameters of opening and closing induction current reach the domestic leading level: electromagnetic induction current: 1250A, 35kV;electrostatic induction current: 50A, 50kV.

4、 Provide one-key sequential control "double confirmation" function expansion.

Main technical parameters

JW10-parameters.png

Order notice 

Product model, rated voltage, rated current, rated short-time withstand voltage and creep distance, etc. shall be specified when ordering Products

Arrangement method of 126-252 kV grounding switch shall be specified - parallel type or one column type;

If the grounding switch requires opening and closing induction current, special specifications and required parameters of opening and closing induction current shall be provided. The side of grounding switch which requires opening and dosing induction current of the disconnector switch shall be specified: (Ps. Only grounding switches used in the input & output circuit of converting station of two circuit parallel transmission line require the function of opening and closing induction current, which is only a minority, Not all the grounding switches and disconnect switches require opening and closing induction current.)

Model of operation mechanism, motor voltage, control voltage and auxiliary switch contact number.


Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Related Products
Related Knowledges
  • How has g3 technology changed the global climate?
    The Alternative to SF6 for High Voltage ApplicationsRemoving Greenhouse Gases from the GridNineteen of the warmest years on record have occurred since 2000, where greenhouse gases (GHGs) are at the root cause of climate change. Sulfur hexafluoride (SF₆), an insulating gas used in high-voltage switchgear, is estimated to contribute 23,500 times more than carbon dioxide (CO₂) to the greenhouse effect and can remain in the atmosphere for 3,200 years. Previously, Power Generation and Transmission ut
    05/09/2026
  • Difference Between Maintenance Earthing Switches and Fast Earthing Switches?
    Maintenance earthing switches and fast earthing switches (FES) are two types of switches with distinct characteristics.Maintenance Earthing SwitchesThese are typically configured alongside the disconnectors on both sides of a circuit breaker. Their sole purpose is to provide safety grounding on both sides of the circuit breaker during equipment maintenance.Fast Earthing Switches (FES)These are positioned on the line side of the outgoing disconnector in an outgoing circuit. They serve two primary
    05/08/2026
  • SiC MOSFET Solid State Circuit Breakers for Low Voltage Protection
    1. Core Principle SummaryIn simple terms, its core principle can be summarized as a three-step AC-DC-AC conversion, with the key step being to increase the frequency first, then transform the voltage.2. Working PrincipleRectification:First, the input line-frequency AC power (e.g., 50 Hz or 60 Hz) is rectified into DC power using power electronic devices (such as IGBTs). This step converts low-frequency AC into stable DC, preparing it for subsequent processing.High-Frequency Chopping (Inversion):
    05/03/2026
  • Solid-State Circuit Breakers Set to Revolutionize Circuit Protection
    Custom modules built with SiC MOSFETs minimize the impacts of short circuits and overloadsNearly every electrical engineer has wondered at some point whether it is possible to design a non-mechanical circuit breaker. There are plenty of reasons for this line of thought: would it not be better to use semiconductors to interrupt faults or handle overload conditions?However, deeper investigation inevitably reveals major obstacles. For one thing, the breakdown voltage of familiar power devices is ar
    05/03/2026
  • 2025 Complete Guide to Solar Cell Selection-Scenario Adaptation
    Solar Panel – Comprehensive Guide to Solar Cell SelectionA systematic selection reference for photovoltaic engineers and technicians, covering technical principles, key parameters, application scenarios and development trends.Data baseline: 2024–2025 industrial mass-production levels (CPIA data)1. The Role of Solar Cells in Photovoltaic SystemsMore than 90% of the conversion efficiency and power generation performance of PV modules are determined by solar cells. As the core semicondu
    05/03/2026
  • Technological Evolution of Silicon Carbide (SiC) Based DC Solid-State Circuit Breakers
    1. Introduction: Protection Challenges in the DC Distribution EraAs the global energy transition accelerates, DC microgrids, high-voltage DC (HVDC) power supplies for data centers, and large-scale energy storage systems have become critical components of power systems. However, DC systems lack a natural zero-crossing point and possess extremely low system impedance, leading to a rapid rate of rise of fault current (di/dt). Traditional mechanical circuit breakers, limited by millisecond-level ope
    04/25/2026
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.