GRW8-01 02 Temperature Monitoring Relay

  • GRW8-01 02 Temperature Monitoring Relay
  • GRW8-01 02 Temperature Monitoring Relay

Key attributes

Brand Switchgear parts
Model NO. GRW8-01 02 Temperature Monitoring Relay
Rated frequency 50/60Hz
Series GRW8

Product descriptions from the supplier

Description

The GRV8-01/02 series is a single-phase voltage monitoring relay designed specifically for industrial automation control systems. This product adopts true effective value measurement technology, which can accurately monitor the voltage status of the power supply network, achieve overvoltage and undervoltage protection and power switching control of the electrical system,

Widely applicable to various types of cabinets such as high and low voltage distribution and control. The specific common cabinet names are as follows:
1. High voltage central cabinet: As the core cabinet for 3-35kV high voltage distribution
2 High voltage ring main unit: commonly used in urban distribution network, residential power supply and other scenarios
3 Low voltage drawer cabinets: Low voltage drawer cabinets such as GCS, MNS, etc
4. Low voltage comprehensive distribution box: This type of cabinet is widely used in urban and rural areas, factories and other places, integrating functions such as metering and distribution
5 Electrical control cabinets: Industrial equipment such as frequency converters and servo drives are often installed in these cabinets in a centralized manner
6 Motor Control Center Cabinet (MCC Cabinet)
7 Network cabinets: in communication base stations and network cabinets in computer rooms
8Transformer cabinet: During the operation of the transformer inside the cabinet, the iron core and winding will experience losses and heat generation, especially when the load is heavy and the temperature is prone to exceed the standard

GRV8-01/02 series single-phase voltage monitoring type voltage relay product features:
1. High precision true effective value measurement
By using True RMS voltage detection technology, accurate voltage data can still be provided in complex power grid environments with harmonic interference or waveform distortion, with a measurement error of ≤ 1%.
2. Flexible work mode configuration
The panel knob allows for quick setting of protection modes such as overvoltage, undervoltage, and window (combination of overvoltage and undervoltage), without the need for auxiliary tools to adjust parameters and improve operational efficiency.
3. Intuitive status indication system
Equipped with multi-color LED indicator lights, real-time display of relay working status (power supply, alarm, action), voltage abnormality type, and fault type, making it easy for on-site operation and maintenance personnel to quickly diagnose the system status.
4. Compact industrial design
The ultra-thin body width is only 18mm, supporting 35mm standard DIN rail installation, effectively saving control cabinet space; Wide temperature range design (-25 ℃~+55 ℃), suitable for harsh industrial environments.

GRV8-01/02 series single-phase voltage monitoring type voltage relay product features:
1. Key equipment voltage protection
Provide overvoltage/undervoltage graded protection for equipment such as electric motors, compressors, and frequency converters to avoid the risk of equipment damage or shutdown caused by abnormal voltage. Integrated into distribution cabinets and control boxes to achieve active protection of core equipment on production lines.
2. Intelligent power management system
Automatically monitor the voltage status of the main and backup power supplies, trigger relay actions when the main power supply is abnormal, seamlessly switch to the backup power supply, and ensure the continuous operation of critical loads.
Suitable for places with strict requirements for power continuity, such as data centers, medical facilities, and fire protection systems.
3. Energy Management Auxiliary Unit
Cooperate with the energy management system to provide real-time feedback on grid voltage quality data, providing a basis for energy efficiency optimization and fault prediction.

Technical parameters GRW8-01 GRW8-02
Function Temperature control Temperature range control
Supply terminals A1-A2
Rated supply voltage AC/DC 24V-240V
Rated supply frequency 50/60Hz
Burden max 2VA
Supply voltage tolerance -15%;+10%
Temperature range -15℃ to +45℃
Hysteresis 0.5℃ to 5℃
Supply indication green LED
Tolerance sensor ±5%
Output 1×SPDT
Current rating 1×16A(AC1)
Switching voltage 250VAC/24VDC
Min.breaking capacity DC 500mW
Output indication red LED
Mechanical life 1×107
Electrical life(AC1) 1×105
Operating temperature -20℃ to+55℃(-4℉to131℉)
Storage temperature -35℃ to+75℃(-22℉to158℉)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage category III.
Pollution degree 2
Max.cable size(mm 2) solid wire max.1×2.5or 2×1.5/with sleeve max.1×2.5(AWG 12)
Tightening torque 0.8Nm
Dimensions 90×18×64mm
Weight 64g
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.