• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions

  • GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions
  • GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions
  • GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions
  • GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions

Key attributes

Brand Switchgear parts
Model NO. GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions
Rated voltage AC220V
Rated normal current 32A
Rated frequency 45Hz-65Hz
Series GPS8-02

Product descriptions from the supplier

Description

The GPS8-02 Over Voltage Protector is designed for industrial and high-load complex environments. Building on over-voltage and under-voltage protection, it adds an adjustable overcurrent protection feature, delivering comprehensive triple protection for voltage and current. Its flexible overcurrent settings precisely accommodate the dynamic load requirements of equipment such as motors and inverters. Combined with wide voltage input, dual-bus design, and a self-reset mechanism, the GPS8-02 ensures stable performance even in harsh environments ranging from -20℃ ~ +60℃ With its compact size and DIN rail mounting, it is an ideal choice for high-security applications such as industrial production lines and data centers, offering full protection against risks like circuit overloads and short circuits to safeguard system continuity and extend equipment lifespan.

Technical parameters:

Model

GPS8-02 Over Voltage Protector

Function

Over voltage, under voltage and over current

Rated supply voltage

AC220V(L-N)

Rated supply frequency

45~65HZ

Operation voltage range

80V~400V(L-N)

Rated operational current

32A,40A,50A,63A,80A(AC1)

Burden

AC max.3VA

Over voltage operation value

OFF,230V~300V

Under voltage operation value

140V~210V,OFF

Over/under voltage action delay

0.1s~10s

Over current operation value

1~32A,40A,50A,63A,80A

Over current action delay

2s~600s

Power-up delay

2s~600s

Reset time

2s~900s

Measurement error

≤1%

Electrical life(AC1)

1*104

Mechanical life

1*106

Operating temperature

-20℃ ~ +60℃

Storage temperature

-35℃ ~ +75℃

Mounting/DIN rail

Din rail EN/IEC 60715

Protection degree

IP40 for front panel/IP20 terminals

Operating position

any

Overvoltage category

Pollution degree

2

Dimensions

82x36x68mm

weight

135g

Documentation Resource Library
Restricted
GPS8-02 Over Voltage Protector
Catalogue
English
Consulting
Consulting
FAQ
Q: Which voltage and current specifications is GPS8-02 suitable for?
A:

It is suitable for common civil and industrial low-voltage scenarios, supporting voltage ranges of AC 220V (single-phase) and AC 380V (three-phase), with optional current specifications such as 32A and 63A (subject to product nameplate). It can meet the protection needs of residential, commercial building and industrial control loops.

Q: What are the core protection functions of GPS8-02?
A:

The core functions include three-in-one protection: over-voltage protection (cuts off power when voltage exceeds the safe threshold), under-voltage protection (triggers power-off when voltage is below the normal range), and over-current protection (responds quickly when circuit current is overloaded), fully protecting electrical equipment from damage caused by abnormal voltage/current.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.