GPS8-02 Protector a Tensione Superiore con Funzioni di Sopratensione Sottotensione e Sovracorrente

  • GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions
  • GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions
  • GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions
  • GPS8-02 Over Voltage Protector with Over voltage, Under Voltage and Over Current Functions

Attributa principalia

Marca Switchgear parts
Numerus Modeli GPS8-02 Protector a Tensione Superiore con Funzioni di Sopratensione Sottotensione e Sovracorrente
Votum nominatum AC220V
currus electricus nominatus 32A
Frequenta nominata 45Hz-65Hz
Series GPS8-02

Descriptiones productorum a fornitori

Descriptio

Protector GPS8-02 contra super tensiones est designatus pro ambientes industriales et complexibus cum oneribus magnis. Super protectionem contra super et sub tensiones, addit functionem protectionis contra supercurrentem adjustabilem, praebens protectionem triplex integralem pro tensione et currente. Flexibiles settings supercurrentis accurate accommodant requirementa dynamicorum onerum aequipmentorum sicut motrices et inverteres. Coniunctus cum latitudine tensionis input, designo dual-bus, et mecanismo auto-reset, GPS8-02 certificat stabilitatem performance etiam in ambientes duris ab -20°C ad +60°C. Cum suo parvo volumine et montatura DIN rail, est optima electio pro applicationibus altae securitatis sicut lineas productionis industriales et centra data, offerens protectionem plenam contra pericula sicut circuitus overloads et short circuits ut tueatur continuitatem systematis et extenda vita aequipmentorum.

Parametri technici:

Modello GPS8-02 Protector contra super tensiones
Function Super tensione, sub tensione et super current
Tensio nominale supply AC220V(L-N)
Frequenza nominale supply 45~65HZ
Range tensio operationis 80V~400V(L-N)
Currentus nominale operationis 32A,40A,50A,63A,80A(AC1)
Burden AC max.3VA
Valore operationis super tensionis OFF,230V~300V
Valore operationis sub tensionis 140V~210V,OFF
Delay actionis super/sub tensionis 0.1s~10s
Valore operationis super current 1~32A,40A,50A,63A,80A
Delay actionis super current 2s~600s
Delay power-up 2s~600s
Tempus reset 2s~900s
Error mensurae ≤1%
Vita electrica(AC1) 1*104
Vita mechanica 1*106
Temperatura operationis -20℃ ~ +60℃
Temperatura storage -35℃ ~ +75℃
Montage/DIN rail Din rail EN/IEC 60715
Gradus protectionis IP40 pro front panel/IP20 terminales
Position operationis any
Categoria super tensionis
Gradus pollutionis 2
Dimensiones 82×36×68mm
Pondus 135g

Bibliotheca Documentorum Rerum
Restricted
GPS8-02 Over Voltage Protector
Catalogue
English
Consulting
Consulting
FAQ
Q: Quae voltage et currentis specificationes conveniunt GPS8-02?
A:

Idoneum est pro communibus scenariis civilibus et industrialibus ad bassam tensionem, supportans angulos tensionis AC 220V (uniphasis) et AC 380V (triphasis), cum specificationibus currentis optionalibus sicut 32A et 63A (sub iudicio inscriptionis producti). Id potest satisfacere necessitatibus protectionis circuitorum residentiarum, aedificiorum commercialium et controllo industriali.

Q: Quae sunt praecipuae functiones protectionis GPS8-02?
A:

Functiones nuclei includunt protectionem tripartitam: protectionem contra super-voltam (interruptio electricitatis cum voltus excedit limen tuto), protectionem contra sub-voltam (activatio interruptoris cum voltus est infra rangum normalem), et protectionem contra super-currentem (responsum celeriter cum currentis circuitus est superonus), omnino protegens apparatus electricos ab damno causato per voltum/currentem anormalem.

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 1000m² Numerus omnium laborantium: Summa Annua Exportatio (USD): 300000000
Locus Operis: 1000m²
Numerus omnium laborantium:
Summa Annua Exportatio (USD): 300000000
Servitia
Genus Negotii: Venditio
Categorias Principales: pars componentium/Instrumenta inspectionis/apparatus electrum altum voltus/Apparatus electri bassa tensione/Instrumenta et mensurae/Instrumenta productiva/Ferramentae electricitatis
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026
Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum