Key attributes

Brand Switchgear parts
Model NO. GGJ 12kV reactive power cabinet for terminal power supply system
Rated voltage 380V
Rated normal current 63-630A
Rated frequency 50/60Hz
Rated capacity 1-600KVar
Series GGJ

Product descriptions from the supplier

Description

The GGJ type low-voltage reactive power compensation cabinet is an intelligent energy-saving core equipment suitable for 380V/400V low-voltage distribution systems. It is designed to solve the problem of reactive power loss caused by inductive loads. By dynamically tracking changes in reactive power in the power grid and automatically switching capacitor banks, it achieves precise compensation and is widely used in various scenarios such as industrial production, commercial buildings, and new energy supporting facilities.
Core performance and technological advantages
Intelligent and precise compensation: equipped with a microcomputer intelligent controller, supporting three-phase or phase separation mixed compensation mode, real-time monitoring of power factor and automatic adjustment, can steadily increase to above 0.95, reduce reactive power by more than 60%, significantly reducing line and transformer losses.
Rapid dynamic response: using voltage zero crossing triggering switching technology, response time ≤ 20ms, adapted to fluctuating loads such as motors and welding machines, switching without inrush current or impact, avoiding equipment damage.
Harmonic control capability: Equipped with a 7%/14% reactance rate reactor, it effectively suppresses 3-13 harmonics, resulting in a total harmonic voltage distortion rate of ≤ 5%, in compliance with the GB/T14549 standard, and is suitable for harmonic source scenarios such as frequency converters and photovoltaic inverters.
Comprehensive safety protection: integrating multiple protection functions such as overvoltage, overload, phase loss, and overcompensation. The capacitor adopts a self-healing design, and the residual voltage drops below 50V after 1 minute of power outage, ensuring safe and reliable operation.
Flexible adaptation and expansion: The modular structure supports 1-16 control circuits, with compensation capacity covering 60-600kvar. It can be expanded in parallel with multiple cabinets and is compatible with various low-voltage switchgear such as GGD, MNS, GCK, etc., to meet the needs of different distribution systems.

Applicable scenarios and core values
Industrial field: Suitable for heavy-duty loads such as motors and compressors in factory workshops, mines, and chemical parks, improving the actual load capacity of transformers, extending equipment life, and achieving an annual power saving rate of 5% -18%.
Commercial buildings: Suitable for lighting and air conditioning systems in shopping malls, office buildings, and residential areas, optimizing power supply quality, avoiding voltage fluctuations that affect the electricity experience, and reducing commercial electricity costs.
New energy supporting facilities: Suitable for the low-voltage side of photovoltaic and energy storage power stations, compatible with fluctuating loads, ensuring grid stability, with a power factor stable at 0.98 or above, meeting the requirements for grid connection of new energy generation.
Infrastructure: Serving street lighting, urban and rural power grid renovation, high-rise building power centers, with a compact structure and protection level of IP30/IP40, suitable for wide temperature environments ranging from -25 ℃ to+55 ℃, and easy installation and maintenance.
This product complies with international and domestic standards such as GB/T15576-2008 and IEC60439. It has an RS-232/485 communication interface, supports remote monitoring and fault warning, and achieves unmanned operation. It is the preferred solution for energy-saving and efficiency improvement of low-voltage distribution systems and optimization of power quality.

Electrical data:
Rated voltage: 380VAC 3~; Rated insulation voltage: 660VAC 3~;
Rated frequency: 50HZ or 60HZ;
Compensation method: a combination of three-phase compensation and single-phase compensation.
Compensation capacity: 1-600kvar.
Compensation methods: cyclic switching, coded switching, fuzzy control automatic switching.
Fastest response time: ≤ 20ms;
Cabinet height: 2000mm, 2200mm;
Width: 600, 800, 1000, 1200mm;
Thickness: 600, 800, 1000mm;
Protection level: IP30.

FAQ
Q: Which terminal power supply scenarios is the GGJ 12kV reactive power cabinet suitable for?
A:

It is ideal for terminal power supply systems such as industrial and mining enterprise substations, residential area distribution networks, commercial building power centers, box-type substation terminals, and rural power grid terminals. It performs exceptionally well in scenarios with frequently changing loads and unstable reactive power.

Q: What core functions does the GGJ 12kV reactive power cabinet for terminal power supply system have?
A:

It mainly realizes three core functions: ① Dynamic reactive power compensation to improve power factor (up to ≥0.95) and reduce electricity fees; ② Harmonic suppression by absorbing harmonic current with special reactors, meeting national harmonic standards; ③ Line loss reduction and transformer load capacity improvement, ensuring stable voltage of terminal power supply systems.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.