Gas insulated switchgear with umbrella skirt double conduit

  • Gas insulated switchgear with umbrella skirt double conduit

Key attributes

Brand Switchgear parts
Model NO. Gas insulated switchgear with umbrella skirt double conduit
Rated voltage 12kV
Rated normal current 630A
Series 235

Product descriptions from the supplier

Description

The 235 umbrella skirt sleeve is a specialized core insulation accessory for 12kV/24kV SF6 free solid insulated ring main unit. The core is compatible with the installation requirements of the 235 specification and serves the dual functions of power transmission, lead insulation, and fixation. It is a key connecting component of the medium voltage distribution system.
Core Features
Adopting a pure solid insulation structure, there is no SF6 gas or oil medium, no leakage or combustion risk, which meets the "intrinsic safety" requirements of green distribution, and the insulation performance is stable and reliable.
The integrated umbrella skirt design significantly increases the creepage distance, enhances the anti pollution flashover ability, has strong surface hydrophobicity, and is suitable for complex and harsh environments such as coastal areas and industrial pollution areas.
Accurately matching the installation size of 235 specifications, the structure is compact and has high mechanical strength, excellent impact resistance and aging resistance, and can resist the influence of vibration and temperature difference changes.
Outstanding sealing and protection performance, moisture-proof and dustproof, easy installation without additional maintenance, effectively reducing operation and maintenance costs, and extending service life.
Applicable scenarios
Suitable for 12kV/24kV SF6 free solid insulated ring main unit, used for connecting cabinet incoming and outgoing lines, PT circuits and other lines, widely used in medium voltage distribution systems such as urban distribution networks, industrial plants, new energy power stations, underground substations, etc.

Product Parameters

Item

Description

Product Name

Gas-insulated Switchgear Double-pass Bushing

Model Number

235

Operating Frequency

50Hz

Rated Voltage

10kV~12kV

Material

Epoxy Resin

Production Process

Vacuum Casting

Operating Environment

Up to 1000m

Applicable Scope

Gas-insulated Switchgear, Box Transformer, Branch Box

FAQ
Q: What is the advantage of the shed structure on 235 bushing?
A:

The shed increases creepage distance to improve pollution flashover resistance, especially suitable for heavy pollution areas; it also enhances heat dissipation and mechanical strength, and reduces the risk of insulation breakdown due to surface pollution.

Q: What is the core function and working principle of 235 bushing with shed?
A:

It is a key insulation accessory for 10kV/12kV inflatable cabinets/RMUs, mainly for electrical insulation and conductor connection. The shed structure extends the creepage distance to prevent pollution flashover; high-purity epoxy resin insulation blocks high-voltage breakdown, while the embedded conductor ensures stable current transmission, matching SF6-free and maintenance-free design concepts.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.